ABB Installation Products R2T15J1-H0240 Outdoor Ranger2 Cable Termination. 15kV, Cable Type - Concentric Neutral/Jacketed…
UPC: 075114305372
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Shrink-fit housing with Elastimold pull-down jacket seal for versatile cable compatibility
- Covers 0.64-2.10in insulation diameter and #2-1250kcmil conductor sizes
- Non-tracking silicone housing with superior weathering and memory characteristics
- Four-shed design for enhanced electrical performance in outdoor environments
- Field-removable center core simplifies installation and maintenance
Specifications
Application | Cable Termination, Outdoor Application, 15kV |
Cable Type | Concentric Neutral Wire |
Color | Gray |
Conductor Size | 1/0 STR AWG , 1/0 COMPR AWG , 2/0 SOL AWG , 2/0 COMPT AWG |
Connection Type | 1-Hole Spade #2-500 kcmil |
Earthing | Products Includes Their Own Grounding System |
Frequency | 60 Hz |
Material | Silicone, Aluminum |
Mounting | Product Need to have Cable Holder (not included) |
Mounting Type | Shrink-fit, Field-removable center core |
Number Of Terminals | (1) Single Phase |
Series | Ranger2 |
Size | Insulation Range: 0.64 inch - 2.10 inch, Conductor: #2-1250 kcmil |
Special Features | Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction |
Standard | IEEE 48 |
Type | Cable Termination - Outdoor - Ranger2 |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

PCT10240-4
15kV, Single Piece Terminator (Class 1), includes Universal Aluminum Rod Contact as standard, Power Cable Termination, Conductor Size - 1/0 Stranded/Compressed or 2/0 Compact/Solid, Use for Insulation Diameter Range from .640 to 1.070 inches.
R2IT15M4N0330
Ranger2 Termination for 15KV indoor application, cable insulation diameter 1.30 -2.10 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 500 /Compact or Solid 600
R2T15J1-H0220
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 1-Hole Spade connector for #2 to 500 kcmil. #2 Stranded to #1 Solid
R2IT15M4N0440
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 440 -Stranded or Compressed 1250 Compact or Solid N/A.
R2IT15M4-N2440
Indoor Ranger2 Cable Termination. 15kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - 1.30 inch - 2.10 inch. Copper 2-Hole Spade #2-1250 kcmil, Conductor 1250 Stranded/Compressed
R2IT15M4-N2380
Ranger2 Termination for 15KV indoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 750 /Compact or Solid 900.
R2IT15M4-N0410
Ranger2 Termination for 15KV indoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Aluminum 2-Hole Spade #2-1250kcmil, Stranded or Compressed 1000.
R2T15J1-N0220-B1
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 220 -Stranded or Compressed #2 Compact or Solid #1. Cable Mounting Bracket - B1 - Stainless Steel - Size .80 inch - 1.25 inch.Frequently Asked Questions
What cable sizes are compatible with R2T15?
The R2T15 termination covers insulation diameters from 0.64 inches (16 mm) to 2.10 inches (53 mm), accommodating #2 AWG through 1250 kcmil cables.
What is the voltage rating of the R2T15 termination?
The R2T15 termination has a voltage rating of 15 kV.
Where can I find installation instructions for the R2T15?
Installation instructions are available as IS-1134 for R2T15J, IS-1135 for R2T15M, and IS-1136 for R2T15L.
What is the ambient operating temperature range for R2T15?
The R2T15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).
What is the ambient operating temperature range for R2T15?
The R2T15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).
What is the voltage rating of the R2T15 termination?
The R2T15 termination has a voltage rating of 15 kV.
What cable sizes are compatible with R2T15?
The R2T15 termination covers insulation diameters from 0.64 inches (16 mm) to 2.10 inches (53 mm), accommodating #2 AWG through 1250 kcmil cables.
Where can I find installation instructions for the R2T15?
Installation instructions are available as IS-1134 for R2T15J, IS-1135 for R2T15M, and IS-1136 for R2T15L.
What cable sizes are compatible with R2T15?
The R2T15 termination covers insulation diameters from 0.64 inches (16 mm) to 2.10 inches (53 mm), accommodating #2 AWG through 1250 kcmil cables.
Where can I find installation instructions for the R2T15?
Installation instructions are available as IS-1134 for R2T15J, IS-1135 for R2T15M, and IS-1136 for R2T15L.
How to Install 15kV & 28kV Ranger 2 Cable Termination
This guide provides step-by-step instructions for the installation of 15kV and 28kV Ranger 2 Cable Terminations for both indoor and outdoor applications, suitable for concentric and jacketed concentric neutral cables. Ensure all apparatus is de-energized before starting.
Estimated time: 1h 30m
Tools needed:
Wire strippers, Crimping tool, Approved solvent, Aluminum oxide abrasive (grit 120 or finer, optional), Vinyl tape, Gloves
Supplies needed:
Silicone Rubber Termination kit, Silicone Lubricant, Grey Silicone Rubber Tape, Sealing Mastic, Elastimold copper or aluminum lug or compatible connector, Concentric or jacketed concentric neutral cable, Binding wire (optional)
- Prepare the Cable
DANGER: All apparatus must be de-energized during installation. Check that the cable size fits within the kit range using the Termination Selection Chart. Train the cable into position and cut to the required length, allowing sufficient neutral wire length for grounding. Prepare the cable by removing the jacket, neutral wires, and semi-con insulation shield according to the dimensions shown in Table 1 (Dimension A) and the provided diagrams, ensuring to allow additional exposed conductor distance for crimping aluminum lugs or connectors. Apply one band of mastic around the cable jacket 1/4" (6mm) from the jacket end, stretching 50%, and cut flush. Bend neutral wires back over and press into the mastic, securing them to the cable jacket 4-6" (100-150mm) from the cut edge with vinyl tape or binding wire. Apply a second mastic band over the neutral wires and the first mastic, stretching 50%, and cut flush. Wrap two half-lapped layers of vinyl tape around the mastic seal, maintaining the 1/4" (6mm) dimension.
- Install the Lug or Connector
If using a lug that will not fit through the termination core, clean the cable insulation and slide the termination onto the cable before installing the lug (do not remove the core at this time). Position the connector or lug and crimp it according to its specific directions, ensuring not to crimp the last 1/4" to 3/8" of the connector. After crimping, remove any excess oxide inhibitor and sharp crimp flashings.
- Clean Cable Insulation and Lug Barrel
Wipe the cable insulation with an approved solvent, taking care not to allow the solvent to touch the semi-con insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation only, and do not use it on the semi-con insulation shield. Be careful not to reduce the cable insulation diameter below the kit's allowed range.
- Install the Termination Body
IMPORTANT: Create a track-resistant moisture seal between the termination insulator and the lug/connector by wrapping a band of grey silicone rubber tape (from the kit) around the base of the terminal lug. If the barrel diameter is smaller than the cable primary insulation, use the tape strip to build up the tape band to equal the insulation diameter. Cover the edge of the semi-con insulation shield with a liberal coating of silicone grease to fill the step at the semi-con cut-off. For lower terminations with a fold-down skirt, pull the loose end of the removable core through the top of the termination until the core is flush with the bottom. Slide the termination body onto the cable, aligning the terminator with the forward edge of the mastic seal. Carefully remove the core by unwinding it counter-clockwise, starting with the loose end. Ensure the termination body, not the core, is butted up to the leading edge of the mastic seal. Do not push or pull on the termination assembly while removing the core material.
- Complete Termination Seal and Grounding
Apply a thin film of silicone lubricant to the skirt and mastic seal area, but do not lubricate the skirt tabs. Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining grey silicone rubber tape, overlapping the termination insulator by approximately 1" and extending the tape wrapping over a non-crimped region of the lug/connector barrel with a half-lap configuration. Twist the concentric neutral wires together and connect them to the system ground. Finally, confirm that the High-K step does not exceed 1.5".
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.