ABB - Installation Products R2T15J1-H0220 - Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 1-Hole Spade connector for #2 to 500 kcmil. #2 Stranded to #1 Solid

ABB Installation Products R2T15J1-H0220 Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12…

UPC: 783786971572


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 15 kV Outdoor Termination (SKU R2T15J1-H0220) provides a field-proven termination solution for Concentric Neutral (CN) and Jacketed Concentric Neutral (JCN) cables in outdoor power distribution. Engineered for cable insulation diameters from 0.64 to 1.12 inches, this termination utilizes shrink-fit technology and Elastimold’s pull-down jacket seal for reliable performance. The non-tracking silicone housing offers superior memory and weathering resistance, featuring four sheds for enhanced creepage and strike distance on this 15kV outdoor model. A field-removable center core simplifies installation. The included aluminum 1-hole spade connector ensures a secure connection for #2 AWG to 500 kcmil conductors. Ranger2 terminations are compatible with popular XLP and EPR cable types and shield constructions. Three sizes in the Ranger2 series cover the full range from #2 AWG to 1250 kcmil. The compact design allows installation in restricted spaces and permits free-hanging applications. Optional insulating silicone sleeves are available for increased creepage or wildlife protection. Ideal for utility substations and industrial power distribution, the Ranger2 series minimizes failure points and reduces inventory complexity.
  • Designed for 15 kV outdoor applications with Concentric Neutral (CN) and Jacketed Concentric Neutral (JCN) cables.
  • Accommodates cable insulation diameters from 0.64 to 1.12 inches.
  • Includes an aluminum 1-hole spade connector for #2 AWG to 500 kcmil conductors.
  • Features a non-tracking silicone housing with four sheds for enhanced creepage and strike distance.
  • Utilizes shrink-fit technology and a pull-down jacket seal for reliable performance.

Specifications

Application
Cable Termination, Outdoor Application, 15kV
Cable Type
Concentric Neutral Wire
Color
Gray
Conductor Size
#2 STR AWG , #2 COMPR AWG , #1 SOL AWG , #1 COMPT AWG
Earthing
Products Includes Their Own Grounding System
Mounting
Product Need to have Cable Holder (not included)
Number Of Terminals
(1) Single Phase
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV, Single Piece Terminator (Class 1), Two Hole Spade Lug. Power Cable Termination, Conductor Size - #2 Stranded/Compressed or #1 Compact/Solid, Use for Insulation Diameter Range from .640 to 1.070 inches.

PCT11220-3

15kV, Single Piece Terminator (Class 1), Two Hole Spade Lug. Power Cable Termination, Conductor Size - #2 Stranded/Compressed or #1 Compact/Solid, Use for Insulation Diameter Range from .640 to 1.070 inches.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 440 -Stranded or Compressed 1250 Compact or Solid N/A.

R2IT15M4N0440

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 440 -Stranded or Compressed 1250 Compact or Solid N/A.
Indoor Ranger2 Cable Termination. 15kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - 1.30 inch - 2.10 inch. Copper 2-Hole Spade #2-1250 kcmil, Conductor 1250 Stranded/Compressed

R2IT15M4-N2440

Indoor Ranger2 Cable Termination. 15kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - 1.30 inch - 2.10 inch. Copper 2-Hole Spade #2-1250 kcmil, Conductor 1250 Stranded/Compressed
Ranger2 Termination for 15KV indoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 750 /Compact or Solid 900.

R2IT15M4-N2380

Ranger2 Termination for 15KV indoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 750 /Compact or Solid 900.
Ranger2 Termination for 15KV indoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Aluminum 2-Hole Spade #2-1250kcmil, Stranded or Compressed 1000.

R2IT15M4-N0410

Ranger2 Termination for 15KV indoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Aluminum 2-Hole Spade #2-1250kcmil, Stranded or Compressed 1000.
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 220 -Stranded or Compressed #2 Compact or Solid #1. Cable Mounting Bracket - B1 - Stainless Steel - Size .80 inch - 1.25 inch.

R2T15J1-N0220-B1

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 220 -Stranded or Compressed #2 Compact or Solid #1. Cable Mounting Bracket - B1 - Stainless Steel - Size .80 inch - 1.25 inch.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 380 -Stranded or Compressed 750 Compact or Solid 900.

R2IT15M4-N0380

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 380 -Stranded or Compressed 750 Compact or Solid 900.
Ranger2 Termination for 15KV indoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Aluminum 2-Hole Spade #2-1250kcmil, Stranded or Compressed 4/0 / Compact or Solid 250.

R2IT15M2N0270

Ranger2 Termination for 15KV indoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Aluminum 2-Hole Spade #2-1250kcmil, Stranded or Compressed 4/0 / Compact or Solid 250.

Frequently Asked Questions

What is the IEEE classification for outdoor use?

The R2T15 termination has an IEEE Classification of Outdoor = Class 1A.

Where can I find installation instructions?

Installation instructions are IS-1134 for R2T15J, IS-1135 for R2T15M, and IS-1136 for R2T15L.

What is the maximum altitude for operation?

The R2T15 termination has a maximum altitude range of 3300 feet (1005 m).

What power system frequency does it support?

The R2T15 termination supports a power system frequency range of 48 to 62 Hz.

What is the operating ambient temperature range?

The R2T15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What is the maximum design voltage to ground?

The maximum design voltage to ground for the R2T15 termination is 9.5 kV.

What is the voltage rating of the R2T15 termination?

The R2T15 termination has a voltage rating of 15 kV.

What cable types are compatible with R2T terminations?

R2T terminations accommodate popular XLP and EPR cable types and various shield constructions.

What cable sizes does the R2T termination support?

The R2T termination supports cable insulation diameters from 0.64 in to 2.10 in, covering #2 AWG through 1250 kcmil cables.

What is the IEEE classification for outdoor use?

The R2T15 termination has an IEEE Classification of Outdoor = Class 1A.

How to Install the R2T15/28J Ranger 2 Cable Termination

This guide provides step-by-step instructions for installing the 15kV & 28kV Ranger 2 Cable Termination on concentric and jacketed concentric neutral cables for indoor/outdoor applications.

Tools needed:

Wire strippers, Crimping tool

Supplies needed:

Silicone Rubber Termination, Lubricant, Grey Silicone Rubber Tape, Sealing Mastic, Gloves, Connector, Cable Support Bracket, Vinyl tape, Binding wire, Approved solvent, Aluminum oxide abrasive (grit 120 or finer)

  1. De-energize Apparatus

    Ensure all apparatus is de-energized during installation or removal of parts to prevent serious or fatal injury. Do not touch or move energized products.

  2. Prepare Cable

    Train the cable into position and cut it to the required length for installation, allowing sufficient neutral wire length for grounding connection. Prepare the cable insulation and conductor using the dimensions shown in the documentation, allowing for terminal lug depth and additional exposed conductor distance for crimping aluminum lugs or connectors.

  3. Apply First Mastic Band

    Carefully wrap one band of sealing mastic around the cable jacket 1/4 inch (6mm) from the jacket end, stretching it to 50%. Position the mastic precisely as it serves as a marker for the terminator. Cut the mastic flush without overlapping.

  4. Secure Neutral Wires

    Bend the neutral wires back over the first mastic band and press them into the sealing mastic. Secure the neutral wires to the cable jacket 4-6 inches (100-150mm) from the cut edge using vinyl tape or binding wire.

  5. Apply Second Mastic Band

    Apply a second band of sealing mastic over the secured neutral wires and the previously applied mastic, stretching it to 50%. Cut the mastic flush without overlapping.

  6. Seal Mastic with Vinyl Tape

    Wrap two half-lapped layers of vinyl tape around the mastic seal, carefully maintaining the 1/4 inch (6mm) dimension from the jacket end.

  7. Install Lug or Connector

    If using lugs that will not fit through the termination core, clean the insulation and slide the termination onto the cable before installing the lug. Position the connector or lug and crimp it according to its directions, ensuring the last 1/4 to 3/8 inch of the connector remains uncrimped. Remove any excess oxide inhibitor and sharp crimp flashings after crimping.

  8. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation with an approved solvent, ensuring the solvent does not touch the semi-con insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation only, and be careful not to reduce the cable insulation diameter below the kit's allowed range.

  9. Apply Silicone Tape Moisture Seal (Lug Base)

    Wrap a band of gray silicone rubber tape around the base of the terminal lug to create a track-resistant moisture seal. If the barrel diameter is smaller than the cable primary insulation, use the tape strip to form a tape band equal to the insulation diameter; otherwise, the tape band should not exceed two layers.

  10. Apply Silicone Grease to Semi-Con Edge

    Cover the edge of the semi-con insulation shield with a liberal coating of silicone grease. This grease is used to fill the step at the semi-con cut-off.

  11. Prepare and Slide Termination Body

    For lower terminations with a fold-down skirt, pull the loose end of the removable core through the top of the termination until the core is flush with the bottom. Slide the termination body onto the cable, aligning the terminator with the forward edge of the mastic seal.

  12. Remove Termination Core

    Carefully begin to remove the core by unwinding it counter-clockwise, starting with the loose end. Ensure the termination body, not the core, is butted up to the leading edge of the mastic seal. Do not push or pull on the termination assembly while removing the core material.

  13. Lubricate and Fold Down Skirt

    Apply a thin film of silicone lubricant to the skirt and mastic seal area, but do not lubricate the skirt tabs. Carefully fold down the skirt over the mastic seal.

  14. Complete Lug Area Moisture Seal

    Using the remaining gray silicone rubber tape, complete the lug area moisture seal. Overlap the termination insulator by approximately 1 inch and extend the tape wrapping over a non-crimped region of the lug/connector barrel with a half-lap configuration.

  15. Connect Neutral Wires to Ground

    Twist the concentric neutral wires together and connect them securely to the system ground.

  16. Confirm High-K Step

    Confirm that the High-K step does not exceed 1.5 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.