ABB - Installation Products R2IT15M2-N0310 - Ranger2 Termination for 15KV indoor application, cable insulation diameter .84 - 1.38 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2 to 1250 kcmil. 400 kcmil Stranded or 500 kcmil Solid

ABB Installation Products R2IT15M2-N0310 Ranger2 Termination for 15KV indoor application, cable insulation diameter .84 - 1.38…

UPC: 783786031542


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Termination (SKU: R2IT15M2-N0310) is a high-reliability, indoor-rated termination designed for 15kV applications with cable insulation diameters ranging from 0.84 to 1.38 inches. This termination supports both concentric neutral and jacketed concentric neutral cables, making it versatile for medium-voltage distribution systems. The included aluminum 2-hole spade connector accommodates conductor sizes from #2 AWG up to 1250 kcmil, covering 400 kcmil stranded or 500 kcmil solid conductors—ideal for high-current industrial and utility installations. Engineered for compatibility with ABB’s Ranger2 series, this termination ensures secure, low-resistance connections in indoor environments where space and reliability are critical. The 15kV voltage rating aligns with ANSI C119.4 and IEEE 386 standards, providing consistent performance in power distribution networks. The compact design and durable aluminum construction reduce installation time while maintaining long-term mechanical and electrical integrity. Common applications include substation terminations, switchgear connections, and industrial motor control centers where medium-voltage cable terminations require precise insulation management and robust conductor termination. The 2-hole spade connector simplifies installation with standard hardware, eliminating the need for custom fittings. For projects requiring reliable 15kV indoor terminations with broad conductor compatibility, the Ranger2 Termination delivers consistent performance and compliance with utility-grade specifications.
  • 15kV voltage rating for medium-voltage indoor applications
  • Supports cable insulation diameters from 0.84 to 1.38 inches
  • Aluminum 2-hole spade connector for #2 to 1250 kcmil conductors
  • Compatible with concentric neutral and jacketed concentric neutral cables
  • Designed for 400 kcmil stranded or 500 kcmil solid conductors

Specifications

Application
Cable Termination, Indoor Application, 15kV
Cable Type
Copper Tape Shielded Wire
Color
Gray
Conductor Size
400 to 500 kcmil
Earthing
Products Includes Their Own Grounding System
Mounting
Product Need to have Cable Holder (not included)
Number Of Terminals
(1) Single Phase
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Indoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 310 -Stranded or Compressed 400 Compact or Solid 500.

R2T15M2N2310

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 310 -Stranded or Compressed 400 Compact or Solid 500.
Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 350/ Compact or Solid 400.

R2IT15M1N2300

Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 350/ Compact or Solid 400.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.

R2IT15M1-N0240

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 270 -Stranded or Compressed 4/0 Compact or Solid 250.

R2IT15J1-N0270

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 270 -Stranded or Compressed 4/0 Compact or Solid 250.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.

R2IT15J1-N0250

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 220 -Stranded or Compressed #2 Compact or Solid #1.

R2IT15J1-N0220

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 220 -Stranded or Compressed #2 Compact or Solid #1.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.

R2IT15J1-N0240

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 440 -Stranded or Compressed 1250 Compact or Solid N/A.

R2T15J4-N0440

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 440 -Stranded or Compressed 1250 Compact or Solid N/A.

Frequently Asked Questions

What is the voltage rating of the R2IT15 termination?

The R2IT15 cable termination has a voltage rating of 15 kV.

What is the maximum altitude for R2IT15 installation?

The R2IT15 termination can be installed at a maximum altitude of 3300 feet (1005 m).

What is the maximum design voltage to ground for R2IT15?

The maximum design voltage to ground for the R2IT15 termination is 9.5 kV.

What is the IEEE classification for the R2IT15 termination?

The R2IT15 termination has an IEEE Classification of Indoor = Class 2.

What is the creepage distance for the R2IT15 termination?

The creepage distance for the R2IT15 termination is 8.4 inches (213 mm).

What is the minimum strike distance for the R2IT15?

The minimum strike distance for the R2IT15 termination is 8.4 inches (213 mm).

What power system frequencies are supported by the R2IT15?

The R2IT15 termination supports power system frequencies ranging from 48 to 62 Hz.

What is the operating temperature range for this termination?

The ambient temperature range for the R2IT15 termination is -22 to +149 °F (-30 to +65 °C).

What AWG cable sizes does the R2IT15 accommodate?

The R2IT15 termination accommodates cable sizes from #2 AWG through 1250 kcmil.

What cable insulation diameters are compatible with R2IT15?

The R2IT15 termination covers cable insulation diameters from 0.64 inches (16 mm) to 2.10 inches (53 mm).

How to Install the 15kV Ranger 2 Silicone Rubber Termination (Tape Shielded Cable)

This guide provides step-by-step instructions for installing the R2IT15M2-N0310 15kV Ranger 2 Shrink fit Silicone Rubber Termination on tape shielded cables for indoor applications.

Estimated time: 1h 30m

Tools needed:

Cable cutter, Crimping tool, Deburring tool/knife, Solvent, Cleaning pads, Aluminum oxide abrasive (120 grit or finer)

Supplies needed:

R2IT15M2-N0310 Termination Kit, Vinyl tape, Copper foil tape, Silicone lubricant/grease, Terminal lug/connector, Gloves, Semi-conductive rubber tape (e.g., Scotcht No. 13, if needed)

  1. De-energize Apparatus and Inspect Kit

    WARNING: All apparatus must be de-energized during installation or removal. Do not touch or move energized products. Inspect the kit contents to ensure they are complete, undamaged, and compatible with the cable and mating parts. Read all instructions before starting.

  2. Prepare Cable for Termination

    Verify the cable size fits the termination selection chart. Train the cable into position and cut it to the required length. Prepare the cable according to the specified dimensions: 9-1/4” (235mm) jacket removal length, 1-1/2” (38mm) for terminal lug depth plus growth allowance, and 3/4” (19mm) tape shield. Secure the tape shield edge with a single wrap of the supplied copper foil tape to prevent unrolling.

  3. Install Ground Braid and Markers

    Wrap one band of vinyl tape 1/4” (6mm) from the cable jacket end as a marker. Position the preformed ground braid with its short tail over the tape shield and the solder block centered over this vinyl tape. Secure the ground braid to the cable jacket with vinyl tape. Apply a second vinyl tape band directly over the first marker and solder block, maintaining the 1/4” (6mm) dimension.

  4. Secure Ground Braid with Constant Force Spring

    Wrap the ground braid around the cable tape shield for one complete wrap, trim any excess to prevent overlap, and secure it in place with the constant force spring. Wrap the spring in the same direction as the ground braid, cinching it after the final winding. Secure the spring with two wraps of vinyl tape. For cloth or paper semi-conductive shields, overwrap with one half-lapped layer of highly stretched semi-conductive rubber tape (e.g., Scotcht No. 13).

  5. Install and Crimp Lug or Connector

    Ensure the termination assembly fits over the selected lug. If not, clean the insulation and slide the termination onto the cable before installing the lug (do not remove the core yet). Position the connector/lug and crimp it according to the manufacturer’s directions, leaving the last 3/8” to 1/2” uncrimped. Remove excess oxide inhibitor and all sharp crimp flashings/edges.

  6. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation with solvent-saturated pads, ensuring solvent does not touch the semi-conductive insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (120 grit or finer) on the insulation only. Do not use abrasive on the semi-conductive insulation shield, and avoid reducing the cable insulation diameter.

  7. Install Silicone Rubber Termination Body

    Liberally coat the edge of the semi-conductive insulation shield with silicone grease to fill the step at the semi-con cut-off. Slide the termination body onto the cable, aligning its edge with the forward edge of the vinyl tape marker. Carefully begin to remove the core by pulling counter-clockwise. Recheck the termination position and continue removing the core, avoiding pushing or pulling on the assembly.

  8. Connect Ground Braid to System Ground

    Connect the installed ground braid securely to the system ground.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.