ABB Installation Products R2IT15J1-N0240 Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed…
UPC: 075114130684
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Indoor 15kV termination for medium-voltage applications
- Compatible with Concentric Neutral/Jacketed Concentric Neutral cable types
- Accommodates insulation diameters from 0.64" to 1.12"
- Aluminum 1-hole spade connector for 2 AWG to 1250 kcmil conductors
- Supports 1/0 AWG compact or 2/0 AWG solid conductors
Specifications
Application | Cable Termination, Indoor Application, 15kV |
Cable Type | Concentric Neutral Wire |
Color | Gray |
Conductor Size | 1/0 STR AWG , 1/0 COMPR AWG , 2/0 SOL AWG , 2/0 COMPT AWG |
Connection Type | 1-Hole Spade |
Earthing | Products Includes Their Own Grounding System |
Material | Aluminum |
Mounting | Product Need to have Cable Holder (not included) |
Number Of Terminals | (1) Single Phase |
Series | Ranger2 |
Size | 0.64 inch - 1.12 inch |
Special Features | Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction |
Standard | IEEE 48 |
Type | Cable Termination - Indoor - Ranger2 |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

PCT10240-4
15kV, Single Piece Terminator (Class 1), includes Universal Aluminum Rod Contact as standard, Power Cable Termination, Conductor Size - 1/0 Stranded/Compressed or 2/0 Compact/Solid, Use for Insulation Diameter Range from .640 to 1.070 inches.
R2T15J4-N0440
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 440 -Stranded or Compressed 1250 Compact or Solid N/A.
R2IT15J4N2380
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 380 -Stranded or Compressed 750 Compact or Solid 900.
R2IT15M1-H0240
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.
R2IT15J1-N0260
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 260 -Stranded or Compressed 3/0 Compact or Solid 4/0.
R2IT15J1-H0250
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.
R2T35M4-N2310-B4
Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 310 -Stranded or Compressed 400 Compact or Solid 500. Cable Mounting Bracket - Stainless Steel, 1.80 inch - 2.40 inch (45-61mm).
R2IT15J1-H0240
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.Frequently Asked Questions
What cable types does the ABB Ranger2 termination support?
The ABB Ranger2 termination supports Concentric Neutral and Jacketed Concentric Neutral cable types.
What is the insulation range for this 15kV termination?
This termination is designed for insulation diameters ranging from 0.64 inches to 1.12 inches.
What conductor sizes can be used with the aluminum spade connector?
The aluminum 1-hole spade connector is suitable for conductor sizes from #2 AWG up to 1250 kcmil.
What specific conductor codes are compatible with this ABB termination?
This termination is compatible with stranded or compressed 1/0 AWG compact conductors, and solid 2/0 AWG conductors.
Is this ABB Ranger2 termination suitable for outdoor use?
No, this ABB Ranger2 termination is specifically designed for indoor use.
How to Install the 15kV Ranger 2 Cable Terminator (Indoor)
This guide provides step-by-step instructions for the safe and proper installation of the 15kV Ranger 2 Cable Terminator for indoor applications on concentric and jacketed concentric neutral cables.
Estimated time: 45m
Tools needed:
Wire cutters, Wire strippers, Crimping tool, Approved solvent, Clean rags/wipes, Aluminum oxide abrasive (grit 120 or finer, optional)
Supplies needed:
15kV Ranger 2 Cable Terminator Kit (Silicone Rubber Termination, Lubricant, Gloves), Cable (concentric or jacketed concentric neutral), Terminal lug or connector (optional), Vinyl tape
- Ensure Safety and Prepare for Installation
Ensure all apparatus is de-energized before starting. Verify kit contents, component compatibility, and read all instructions. Gather tools and maintain a clean work area. This product must be installed by competent personnel trained in high voltage electrical equipment safety practices. Failure to follow instructions can result in serious injury or product damage.
- Prepare the Cable
Verify cable size fits the kit range. Train the cable into position and cut to length, allowing sufficient neutral wire for grounding. Prepare the cable using the specified dimensions (9-1/2" jacket, 1-1/2" neutral wires, semi-con cut back based on cable size). Bend neutral wires back and secure them.
- Install the Terminal Lug or Connector
If using a lug that won't fit through the termination core, clean the cable insulation and slide the termination onto the cable before installing the lug; do not remove the core yet. Position and crimp the connector/lug per manufacturer's directions, avoiding crimping the last 1/4” to 3/8”. Remove excess oxide inhibitor and sharp crimp flashings.
- Clean Cable Insulation and Lug Barrel
Wipe the cable insulation with an approved solvent, ensuring it does not touch the semi-con insulation shield. If abrasive cleaning is needed, use only aluminum oxide abrasive (grit 120 or finer) on the insulation, and do not reduce the cable insulation diameter below the kit's allowed range.
- Install the Termination Body
Apply a liberal coating of silicone grease to the edge of the semi-con insulation shield to fill the step at the cut-off. Slide the terminator body onto the cable and align its skirt with the cable jacket edge. Carefully remove the core by rotating the lead counter-clockwise while pulling. Recheck position and continue removing the core, avoiding pushing or pulling the assembly.
- Ground the Neutral Wires
Twist the concentric neutral wires together and connect them securely to the system ground.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.