Authorized ABB Distributor (Installation Products)
ABB - Installation Products R2IT15J1-N0250 - Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.

ABB Installation Products R2IT15J1-N0250 Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed…

UPC: 075114130707


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Termination (SKU: R2IT15J1-N0250) is a Type Indoor termination designed for 15kV cables with concentric neutral or jacketed concentric neutral construction. It accommodates insulation diameters from 0.64 inch to 1.12 inch, covering a wide range of cable types including stranded or compressed 2/0 compact or solid 3/0 conductors. The termination features an aluminum 1-hole spade connector rated for #2 to 1250 kcmil, ensuring compatibility with high-capacity power distribution systems. This termination is engineered for indoor applications where reliable electrical connection and insulation integrity are critical. The concentric neutral design provides enhanced grounding and fault current handling, while the jacketed option adds an extra layer of mechanical protection. The Ranger2 series is part of ABB’s proven termination portfolio, trusted in utility, industrial, and commercial installations for medium-voltage systems. Key benefits include simplified installation with pre-engineered components, consistent performance across specified conductor sizes, and compatibility with standard 15kV cable constructions. The termination’s design aligns with industry standards for medium-voltage terminations, ensuring long-term reliability in operational environments.
  • 15kV rated for indoor medium-voltage cable terminations
  • Supports concentric neutral and jacketed concentric neutral cables
  • Insulation diameter range: 0.64 inch to 1.12 inch
  • Aluminum 1-hole spade connector for #2 to 1250 kcmil conductors
  • Compatible with stranded/compressed 2/0 and solid 3/0 conductors

Specifications

Application
Cable Termination, Indoor Application, 15kV
Cable Type
Concentric Neutral Wire
Color
Gray
Conductor Size
2/0 STR AWG , 2/0 COMPR AWG , 3/0 SOL AWG , 3/0 COMPT AWG
Earthing
Products Includes Their Own Grounding System
Mounting
Product Need to have Cable Holder (not included)
Number Of Terminals
(1) Single Phase
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Indoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Outdoor, Ranger2 Termination, 15kV, Concentric Neutral/Jacketed Concentric Neutral Cable Type, Insulation Range - .64-1.12 inch (16-28mm). Connector Type Universal Aluminum Barrel for AL or CU Conductor with Copper Wire Lead #2-4/0. Conductor - 2/0 Stranded/Compressed or 3/0 Compact/Solid. Cable Mounting Bracket Material - Stainless Steel, Size .80-1.25 inch (20-32mm).

R2T15J1-T0250-B1

Outdoor, Ranger2 Termination, 15kV, Concentric Neutral/Jacketed Concentric Neutral Cable Type, Insulation Range - .64-1.12 inch (16-28mm). Connector Type Universal Aluminum Barrel for AL or CU Conductor with Copper Wire Lead #2-4/0. Conductor - 2/0 Stranded/Compressed or 3/0 Compact/Solid. Cable Mounting Bracket Material - Stainless Steel, Size .80-1.25 inch (20-32mm).
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 220 -Stranded or Compressed #2 Compact or Solid #1.

R2IT15J1-N0220

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 220 -Stranded or Compressed #2 Compact or Solid #1.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.

R2IT15J1-N0240

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 440 -Stranded or Compressed 1250 Compact or Solid N/A.

R2T15J4-N0440

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 440 -Stranded or Compressed 1250 Compact or Solid N/A.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 380 -Stranded or Compressed 750 Compact or Solid 900.

R2IT15J4N2380

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 380 -Stranded or Compressed 750 Compact or Solid 900.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.

R2IT15M1-H0240

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 260 -Stranded or Compressed 3/0 Compact or Solid 4/0.

R2IT15J1-N0260

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 260 -Stranded or Compressed 3/0 Compact or Solid 4/0.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.

R2IT15J1-H0250

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.

Frequently Asked Questions

What are the insulation withstand voltage ratings?

The insulation withstand voltage ratings include 110 kV Crest for Lightning Impulse, 50 kV for 1 Minute Dry (60Hz), 35 kV for 5 Hour Dry (60Hz), and 75 kV for DC Withstand 15 min. Dry.

What is the minimum strike distance for the R2IT15?

The minimum strike distance for the R2IT15 termination is 8.4 in (213 mm).

What is the coronal extinction voltage for R2IT15?

The coronal extinction voltage (Partial Discharge) for the R2IT15 termination is 13 kV (≤ 3pC).

Does the R2IT15 termination use shrink-fit technology?

Yes, the R2IT15 termination design incorporates shrink-fit technology. This allows it to cover a wide range of applications with fewer models.

What is the voltage rating of the R2IT15 termination?

The R2IT15 cable termination has a voltage rating of 15 kV. Its maximum design voltage to ground is 9.5 kV.

What cable sizes are compatible with R2IT15 terminations?

The R2IT15 terminations accommodate cable sizes from #2 AWG through 1250 kcmil. They cover insulation diameters from 0.64 in (16 mm) to 2.10 in (53 mm).

What is the operating temperature range for this product?

The ambient temperature range for the R2IT15 termination is -22 to +149 °F (-30 to +65 °C).

What is the maximum altitude for R2IT15 installation?

The R2IT15 termination can be installed at an altitude range of up to 3300 feet max (1005 m).

What is the IEEE classification for the R2IT15 termination?

The R2IT15 termination has an IEEE classification of Indoor = Class 2.

What is the power system frequency range for R2IT15?

The R2IT15 termination is designed for a power system frequency range of 48 to 62 Hz.

How to Install the 15kV Ranger 2 Cable Terminator (R2IT15J)

This guide provides step-by-step instructions for preparing the cable, installing the lug, cleaning, and installing the 15kV Ranger 2 Cable Terminator for indoor applications. Installation must be performed by competent personnel on de-energized apparatus.

Estimated time: 1h 30m

Tools needed:

Cable cutters, Measuring tape, Wire strippers or cable knife, Crimping tool, Rags or wipes

Supplies needed:

15kV Ranger 2 Cable Terminator Kit (includes termination, lubricant, gloves), Terminal lug or connector, Approved solvent, Vinyl tape, Grounding connection materials, Silicone grease (from kit)

  1. Prepare Cable and Ensure Safety

    Before starting, ensure all apparatus is de-energized to prevent serious injury or fatality. Verify the cable size fits within the kit's specified range as per the Termination Selection Chart. Train the cable into its final position and cut it to the required length, allowing sufficient neutral wire length for grounding connection. Prepare the cable by removing the jacket, neutral wires, and semi-con insulation shield according to the provided dimensions, accounting for terminal lug depth and additional conductor length for aluminum lugs. Secure the neutral wires as instructed.

  2. Install the Terminal Lug or Connector

    Confirm the chosen terminal lug or connector is compatible and fits the cable. If using a lug that will not fit through the termination core, slide the termination body onto the cable first (do not remove its core yet). Position the lug or connector and crimp it according to the manufacturer's directions, ensuring the last 1/4 to 3/8 inch remains uncrimped. After crimping, remove any excess oxide inhibitor and sharp crimp flashings.

  3. Clean Cable Insulation and Lug Barrel

    Thoroughly wipe the cable insulation with an approved solvent, taking care not to let the solvent touch the semi-con insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation, avoiding the semi-con shield. Be careful not to reduce the cable insulation diameter below the kit's allowed specifications.

  4. Install the Termination Body and Ground

    Apply a liberal coating of silicone grease to the edge of the semi-con insulation shield to fill the step. Carefully slide the termination body onto the cable, aligning its skirt with the edge of the cable jacket. Begin removing the core by rotating it counter-clockwise while gently pulling. Recheck the terminator's position and continue removing the core, ensuring not to push or pull on the terminator assembly during this process. Finally, twist the concentric neutral wires together and securely connect them to the system ground.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.