ABB - Installation Products R2T15J4-N0440 - Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 440 -Stranded or Compressed 1250 Compact or Solid N/A.

ABB Installation Products R2T15J4-N0440 Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed…

UPC: 075114147392


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB Ranger2 Termination (SKU: R2T15J4-N0440) is a Type Outdoor termination designed for 15kV concentric neutral or jacketed concentric neutral cables with insulation diameters between 1.30 inch and 2.10 inch. This termination features an aluminum 2-hole spade connector rated for #2-1250 kcmil conductors, supporting stranded, compressed, or solid conductor configurations. The compact design accommodates 440-strand or compressed 1250 kcmil conductors, making it suitable for utility, substation, and industrial applications where reliable medium-voltage cable termination is critical. The outdoor-rated construction ensures long-term performance in exposed environments, reducing maintenance requirements and improving system reliability. Compatible with standard 15kV class equipment, this termination simplifies installation while meeting industry standards for safety and electrical performance. The 2-hole spade connector provides secure mechanical and electrical connection, minimizing risk of loosening or arcing under load. Designed for use with concentric neutral cables, it ensures proper grounding and shielding continuity in medium-voltage distribution systems.
  • Outdoor-rated termination for 15kV concentric neutral/jacketed concentric neutral cables
  • Insulation range: 1.30 inch to 2.10 inch diameter
  • Aluminum 2-hole spade connector rated for #2-1250 kcmil conductors
  • Supports stranded, compressed, or solid 440-strand 1250 kcmil conductors
  • Compact design for utility, substation, and industrial applications

Specifications

Application
Cable Termination, Outdoor Application, 15kV
Cable Type
Concentric Neutral Wire
Color
Gray
Conductor Size
1250 kcmil
Connection Type
Aluminum 2-Hole Spade #2-1250 kcmil
Earthing
Products Includes Their Own Grounding System
Mounting
Product Need to have Cable Holder (not included)
Mounting Type
Outdoor
Number Of Terminals
(1) Single Phase
Series
Ranger2
Size
1.30 inch - 2.10 inch
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Indoor Ranger2 Cable Termination. 15kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - 1.30 inch - 2.10 inch. Copper 2-Hole Spade #2-1250 kcmil, Conductor 1250 Stranded/Compressed

R2IT15M4-N2440

Indoor Ranger2 Cable Termination. 15kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - 1.30 inch - 2.10 inch. Copper 2-Hole Spade #2-1250 kcmil, Conductor 1250 Stranded/Compressed
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 380 -Stranded or Compressed 750 Compact or Solid 900.

R2IT15J4N2380

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 380 -Stranded or Compressed 750 Compact or Solid 900.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.

R2IT15M1-H0240

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 260 -Stranded or Compressed 3/0 Compact or Solid 4/0.

R2IT15J1-N0260

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 260 -Stranded or Compressed 3/0 Compact or Solid 4/0.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.

R2IT15J1-H0250

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.
Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 310 -Stranded or Compressed 400 Compact or Solid 500. Cable Mounting Bracket - Stainless Steel, 1.80 inch - 2.40 inch (45-61mm).

R2T35M4-N2310-B4

Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 310 -Stranded or Compressed 400 Compact or Solid 500. Cable Mounting Bracket - Stainless Steel, 1.80 inch - 2.40 inch (45-61mm).
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.

R2IT15J1-H0240

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 310 -Stranded or Compressed 400 Compact or Solid 500. Cable Mounting Bracket - B2 - Stainless Steel - Size 1.10 inch - 1.50 inch.

R2IT15J2-N2310-B2

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 310 -Stranded or Compressed 400 Compact or Solid 500. Cable Mounting Bracket - B2 - Stainless Steel - Size 1.10 inch - 1.50 inch.

Frequently Asked Questions

What is the maximum design voltage to ground for R2T15?

The maximum design voltage to ground for the R2T15 termination is 9.5 kV.

What cable sizes are compatible with R2T15 terminations?

The R2T15 terminations cover cable insulation diameters from 0.64 inches to 2.10 inches, accommodating #2 AWG through 1250 kcmil cables.

What is the voltage rating of the R2T15 termination?

The R2T15 termination has a voltage rating of 15 kV.

What is the maximum operating temperature for the R2T15?

The R2T15 termination has an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What is the maximum altitude for R2T15 installation?

The R2T15 termination can be installed at a maximum altitude of 3300 feet (1005 m).

What is the power system frequency range for R2T15?

The R2T15 termination is designed for a power system frequency range of 48 to 62 Hz.

What is the IEEE classification for the R2T15 outdoor termination?

The R2T15 outdoor termination has an IEEE Classification of Class 1A.

Where can I find installation instructions for R2T15 terminations?

Installation instructions are IS-1134 for R2T15J, IS-1135 for R2T15M, and IS-1136 for R2T15L.

What is the maximum altitude for R2T15 installation?

The R2T15 termination can be installed at a maximum altitude of 3300 feet (1005 m).

What is the power system frequency range for R2T15?

The R2T15 termination is designed for a power system frequency range of 48 to 62 Hz.

How to Install 15kV & 28kV Ranger 2 Cable Termination

This guide provides detailed instructions for installing the R2T15/28J Ranger 2 Cable Termination on concentric and jacketed concentric neutral cables for indoor/outdoor applications. Ensure all safety precautions are followed.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Crimping tool, Approved solvent, Aluminum oxide abrasive (grit 120 or finer), Vinyl tape or binding wire

Supplies needed:

Silicone Rubber Termination, Lubricant, Grey Silicone Rubber Tape, Sealing Mastic, Gloves, Connector (optional), Cable Support Bracket (optional), Terminal lug

  1. De-energize and Prepare Cable

    DANGER: De-energize all apparatus before beginning installation. Confirm the cable size fits within the kit range. Train the cable into position and cut to the required length, allowing sufficient neutral wire length for grounding. Prepare the cable by stripping the jacket, semi-con, and insulation to the specified dimensions, accounting for terminal lug depth and conductor growth during crimping. Wrap one band of sealing mastic around the cable jacket 1/4 inch (6mm) from the jacket end, stretching 50%, and cut flush. Bend neutral wires back over the mastic, press them in, and secure them to the cable jacket 4-6 inches (100-150mm) from the cut edge using vinyl tape or binding wire. Apply a second mastic band over the neutral wires and previous mastic, stretching 50% and cutting flush. Wrap two half-lapped layers of vinyl tape over the mastic seal, maintaining the 1/4 inch (6mm) dimension.

  2. Install and Crimp Lug or Connector

    If using a lug that does not fit through the termination core, clean the insulation and slide the termination body onto the cable before installing the lug (do not remove the core yet). Position the connector or lug and crimp it according to its specific directions. Do not crimp the last 1/4 to 3/8 inch of the connector. After crimping, remove any excess oxide inhibitor and sharp crimp flashings.

  3. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation with an approved solvent, ensuring the solvent does not touch the semi-con insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation only, avoiding the semi-con shield. Be careful not to reduce the cable insulation diameter below the kit's allowed range.

  4. Install Termination Body

    Create a track-resistant moisture seal between the termination insulator and lug/connector using the gray silicone rubber tape from the kit. Wrap a band of silicone tape around the base of the terminal lug; if the barrel diameter is smaller than the cable primary insulation, build up the tape band to equal the insulation diameter. Cover the edge of the semi-con insulation shield with a liberal coating of silicone grease to fill the step at the semi-con cut-off. For lower terminations with a fold-down skirt, pull the loose end of the removable core through the top of the termination until it is flush with the bottom. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully remove the core by unwinding it counter-clockwise, starting with the loose end. Ensure the termination body is butted up to the leading edge of the mastic seal without pushing or pulling the assembly.

  5. Complete Sealing and Grounding

    Apply a thin film of silicone lubricant to the skirt and mastic seal area, but do not lubricate the skirt tabs. Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining gray silicone rubber tape, overlapping the termination insulator by approximately 1 inch and extending the tape wrapping over a non-crimped region of the lug/connector barrel with a half-lap configuration. Twist the concentric neutral wires together and connect them to the system ground. Finally, confirm that the High-K step does not exceed 1.5 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.