ABB Installation Products R2IT15J1-N0270 Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed…
UPC: 075114130721
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Rated for 15kV indoor applications with concentric neutral or jacketed concentric neutral cables
- Supports insulation diameters from .64 inch to 1.12 inch
- Compatible with 270-strand, 4/0 compact or solid 250 kcmil conductors
- Aluminum 1-hole spade connector (#2-1250 kcmil) for secure electrical contact
- Designed for indoor environments with environmental sealing
Specifications
Application | Cable Termination, Indoor Application, 15kV |
Cable Type | Concentric Neutral Wire |
Color | Gray |
Conductor Size | 4/0 AWG , 250 kcmil |
Earthing | Products Includes Their Own Grounding System |
Mounting | Product Need to have Cable Holder (not included) |
Number Of Terminals | (1) Single Phase |
Special Features | Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction |
Standard | IEEE 48 |
Type | Cable Termination - Indoor - Ranger2 |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

PCT10270-3
15kV, Single Piece Terminator (Class 1), Two Hole Spade Lug. Power Cable Termination, Conductor Size - 4/0 Stranded/Compressed, Use for Insulation Diameter Range from .640 to 1.070 inches.
R2IT15J1-N0250
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.
R2IT15J1-N0220
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 220 -Stranded or Compressed #2 Compact or Solid #1.
R2IT15J1-N0240
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.
R2T15J4-N0440
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 440 -Stranded or Compressed 1250 Compact or Solid N/A.
R2IT15J4N2380
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 380 -Stranded or Compressed 750 Compact or Solid 900.
R2IT15M1-H0240
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.
R2IT15J1-N0260
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 260 -Stranded or Compressed 3/0 Compact or Solid 4/0.Frequently Asked Questions
What is the voltage rating of the R2IT15 termination?
The R2IT15 indoor cable termination has a voltage rating of 15 kV.
What is the maximum altitude for installing the R2IT15 termination?
The R2IT15 termination can be installed at a maximum altitude of 3300 feet (1005 m).
What is the IEEE classification for the R2IT15 indoor termination?
The R2IT15 indoor termination has an IEEE classification of Indoor = Class 2.
What items are included in a standard R2IT15 termination kit?
Each kit contains one Ranger2 Housing, two silicone lubricants, one plastic glove, and optionally a connector, crimp chart, or support bracket if ordered.
Where can I find installation instructions for the R2IT15 termination?
Installation instructions are IS-1134 for R2IT15J, IS-1135 for R2IT15M, and IS-1136 for R2IT15L.
What power system frequency does the R2IT15 termination support?
The R2IT15 termination is designed for power system frequencies ranging from 48 to 62 Hz.
What is the ambient temperature range for the R2IT15 termination?
The R2IT15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).
What cable sizes are compatible with the R2IT15 termination?
The R2IT15 termination accommodates cable sizes from #2 AWG through 1250 kcmil.
What cable insulation diameters does the R2IT15 termination support?
The R2IT15 termination covers cables with insulation diameters from 0.64 in (16 mm) to 2.10 in (53 mm).
What is the minimum strike distance for the R2IT15 termination?
The minimum strike distance for the R2IT15 termination is 8.4 in (213 mm).
How to Install the 15kV Ranger 2 Indoor Cable Terminator
This guide provides instructions for installing the 15kV Ranger 2 Cable Terminator on concentric and jacketed concentric neutral cables for indoor applications. This kit does not provide a moisture-resistant seal.
Estimated time: 1h 30m
Tools needed:
Cable cutters, Wire strippers, Crimping tool, Approved solvent dispenser, Aluminum oxide abrasive (grit 120 or finer), Measuring tape
Supplies needed:
15kV Ranger 2 Cable Terminator kit (Silicone Rubber Termination, Lubricant, Gloves), Connector or Lug (Elastimold copper or aluminum recommended), Vinyl Tape, Approved solvent, Aluminum oxide abrasive (grit 120 or finer), Cable Support Bracket (optional)
- Prepare the Cable
WARNING: Ensure all apparatus is de-energized before beginning installation. This product should only be installed by competent personnel trained in high-voltage safety practices. First, verify the cable size fits within the kit's specified range using the Termination Selection Chart. Next, train the cable into its final position and cut it to the required length, ensuring sufficient neutral wire length for grounding. Prepare the cable according to the provided dimensions, allowing for the terminal lug's depth and additional exposed conductor distance for aluminum lug crimping growth (1/4" for #2-350, 1/2" for 400-650, 3/4" for 750-1000). Finally, bend the neutral wires back and secure them as instructed in the diagram.
- Install the Lug or Connector
If using a lug that will not fit through the termination core, clean the cable insulation and slide the termination body onto the cable before installing the lug; do not remove the core at this time. Position the connector or lug onto the prepared conductor. Crimp the connector or lug according to the manufacturer's directions, leaving the last 1/4" to 3/8" uncrimped. Remove any excess oxide inhibitor and sharp crimp flashings after crimping.
- Clean Cable Insulation and Lug Barrel
Wipe the cable insulation with an approved solvent, taking care not to let the solvent touch the semi-con insulation shield. If abrasive cleaning is necessary, use only on the insulation, not on the semi-con insulation shield. Use only aluminum oxide abrasive, grit 120 or finer, and be careful not to reduce the cable insulation diameter below the kit's allowed range.
- Install the Termination Body
Apply a liberal coating of silicone grease to the edge of the semi-con insulation shield; this grease fills the step at the semi-con cut-off. Carefully slide the terminator body onto the cable, aligning its skirt with the edge of the cable jacket. Begin removing the core by rotating the lead counter-clockwise while pulling. Recheck the terminator's position and continue core removal. Do not push or pull on the terminator assembly during this process. Finally, twist the concentric neutral wires together and connect them securely to the system ground.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.