ABB Installation Products R2T15M2N2310 Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/…
UPC: 075114184281
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Outdoor-rated 15kV termination
- Accommodates cable insulation: 0.84" - 1.38"
- Supports tape shield, wire shield, and unshielded cable types
- Copper 2-hole spade connector for #2 - 1250 kcmil conductors
- Compatible with conductor codes 310 (400 kcmil) and 500 kcmil
Specifications
Application | Cable Termination, Outdoor Application, 15kV |
Cable Type | Copper Tape Shielded Wire |
Color | Gray |
Conductor Size | 400 to 500 kcmil |
Earthing | Products Includes Their Own Grounding System |
Mounting | Product Need to have Cable Holder (not included) |
Number Of Terminals | (1) Single Phase |
Special Features | Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction |
Standard | IEEE 48 |
Type | Cable Termination - Outdoor - Ranger2 |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

R2T15M2-N0310
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 0.84 - 1.38 inches for Cable Type - Tape Shield/Wire Shield/ UniShield. Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 400 /Compact or Solid 500
R2T15M2-T0250
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84 - 1.38 inches for Tape Shield, Wire Shield, and Unshielded Cable, includes Universal Aluminum Barrel For AL or CU Conductor w/copper wire lead
R2T15M4-N0350
15 kv, Cable Terminator Ranger2, Outdoor, Cable Type - Tape Shield/Wire Shield/UniShield, Insulation Range 4 - 1.30 inch to 2.10 inch (33 mm to 53 mm), Connector Type N0 - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code 350 - Compressed 650/Compact 750
R2T15J1-T0270
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For AL or CU Conductor w/copper wire lead #2 to 4/0. 4/0 Stranded or 250 kcmil Solid
R2T15J1-N0330
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 2 Hole Spade #2-1250kcmil, Stranded or Compressed 500 /Compact or Solid 600.
R2T35J2-N0250
Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 2/0 /Compact or Solid 3/0
R2T15J1-N0270
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2 to 1250 kcmil. 4/0 Stranded or 250 kcmil Solid
R2T15J1-N0250
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.Frequently Asked Questions
What is the voltage rating of the R2T15 cable termination?
The R2T15 cable termination has a voltage rating of 15 kV. Its maximum design voltage to ground is 9.5 kV.
What is the acceptable ambient temperature range for the R2T15?
The R2T15 cable termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).
What cable sizes and types are compatible with the R2T15 termination?
The R2T15 termination accommodates #2 AWG through 1250 kcmil cables with insulation diameters from 0.64 in to 2.10 in. It is compatible with popular XLP and EPR cable types.
What is the acceptable ambient temperature range for the R2T15?
The R2T15 cable termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).
What is the voltage rating of the R2T15 cable termination?
The R2T15 cable termination has a voltage rating of 15 kV. Its maximum design voltage to ground is 9.5 kV.
What cable sizes and types are compatible with the R2T15 termination?
The R2T15 termination accommodates #2 AWG through 1250 kcmil cables with insulation diameters from 0.64 in to 2.10 in. It is compatible with popular XLP and EPR cable types.
What cable sizes and types are compatible with the R2T15 termination?
The R2T15 termination accommodates #2 AWG through 1250 kcmil cables with insulation diameters from 0.64 in to 2.10 in. It is compatible with popular XLP and EPR cable types.
What is the voltage rating of the R2T15 cable termination?
The R2T15 cable termination has a voltage rating of 15 kV. Its maximum design voltage to ground is 9.5 kV.
What is the acceptable ambient temperature range for the R2T15?
The R2T15 cable termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).
What material is the R2T15 housing made from?
The R2T15 termination features a non-tracking silicone housing, providing superior memory and weathering characteristics for long-term service.
How to Install the R2T15/28M Ranger 2 Silicone Rubber Termination for Tape Shielded Cables
This guide provides step-by-step instructions for the safe and proper installation of the R2T15/28M Ranger 2 Shrink fit Silicone Rubber Termination on tape shielded cables, including cable preparation, ground braid installation, and termination placement.
Estimated time: 1h 30m
Tools needed:
Crimping tool, Wire strippers, Measuring tape, Utility knife
Supplies needed:
R2T15/28M Silicone Rubber Termination kit, Silicone Lubricant, Gray Silicone Rubber Electrical Tape, Constant Force Spring, Preformed Ground Braid, Sealing Mastic, Copper Foil Tape, Gloves, Vinyl Tape, Approved Solvent, Aluminum Oxide Abrasive (optional), Terminal Lug or Connector
- Prepare the Cable
DANGER: Ensure all apparatus is de-energized before starting. Verify the cable size is compatible with the termination kit using the selection chart. Train the cable into its final position and cut it to the required length, accounting for the terminal lug depth and any growth allowance for aluminum lugs. Remove the cable jacket and tape shield according to the specified dimensions, securing the tape shield edge with a single wrap of copper foil tape.
- Install the Ground Braid
Apply one band of sealing mastic around the cable jacket, 1/4 inch (6mm) from the jacket end, stretching it to 50%. Position the preformed ground braid with its short tail over the tape shield and the solder block centered on the mastic. Secure the ground braid to the cable jacket with vinyl tape and press the solder block into the mastic. Apply a second mastic band over the solder block and the first mastic, then wrap two half-lapped layers of vinyl tape over the mastic seal. Wrap the ground braid once around the cable tape shield, trim any excess, and secure it with the constant force spring, wrapping the spring in the same direction as the braid. Cinch the spring tightly and secure it with two wraps of vinyl tape.
- Install the Terminal Lug or Connector
Verify that the termination assembly can fit over your chosen terminal lug or connector. If it cannot, slide the termination body onto the cable before installing the lug, ensuring the removable core remains in place. Position the lug or connector and crimp it according to the manufacturer's instructions, leaving the last 3/8 to 1/2 inch uncrimped. After crimping, remove any excess oxide inhibitor and all sharp crimp flashings or edges.
- Clean Cable Insulation and Lug
Clean the cable insulation thoroughly using an approved solvent and pads, taking care not to let the solvent contact the semi-conductive insulation shield. If necessary, use only 120-grit or finer aluminum oxide abrasive on the insulation, avoiding the semi-conductive shield and ensuring the cable insulation diameter is not reduced.
- Install the Termination Body
Create a track-resistant moisture seal by wrapping gray silicone rubber electrical tape around the base of the terminal lug. If the lug barrel diameter is smaller than the cable's primary insulation, build up the tape to match the insulation diameter. Apply a liberal coating of silicone grease to the edge of the semi-conductive insulation shield to fill the step. Pull the loose end of the removable core through the top of the termination until it is flush with the bottom. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully remove the core by unwinding it counter-clockwise, ensuring the termination body remains butted against the mastic seal. Do not push or pull the termination during core removal.
- Seal and Finalize Termination
Apply a thin film of silicone lubricant to the termination skirt and mastic seal area, avoiding the skirt tabs. Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining gray silicone rubber electrical tape, overlapping the termination insulator by approximately 1 inch and extending it over a non-crimped region of the lug/connector barrel with a half-lap configuration. Finally, connect the ground braid to the system ground and confirm that the High-K step does not exceed 1.5 inches.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.