Overview

The ABB Ranger2 15KV Indoor Cable Termination (SKU: R2IT15M1N2300) delivers reliable, high-performance termination for medium-voltage power cables in indoor electrical infrastructure. Designed to meet IEEE 48 standards, this termination supports tape shield, wire shield, and unshielded cable types with insulation diameters from 0.64 to 1.12 inches (16 mm to 53 mm). The integrated copper lug features a 2-hole spade configuration, compatible with stranded or compressed conductors from #2 AWG up to 1250 kcmil, as well as solid conductors from 400 kcmil to 1250 kcmil. Key specifications include a maximum design voltage to ground of 9.5 kV, a coronal extinction voltage of ≤3pC at 13 kV, and a lightning impulse withstand rating of 110 kV crest. The termination withstands 1-minute dry 60Hz voltage of 50 kV, 5-hour dry 60Hz voltage of 35 kV, and 15-minute DC withstand of 75 kV. Its non-tracking silicone housing ensures superior memory and weathering resistance, while the shrink-fit design simplifies installation with common cable preparation dimensions. The Ranger2 series is engineered for long-term service in indoor conditions, accommodating ambient temperatures from -22°F to +149°F (-30°C to +65°C) and altitudes up to 3300 feet (1005 m). It installs in restricted spaces and supports free-hanging applications or optional mounting brackets. Optional insulating silicone sleeves provide additional creepage distance and wildlife protection. Three sizes cover the entire cable range, making it a versatile solution for medium-voltage power distribution in industrial and commercial settings.
  • Accommodates cable insulation diameters from 0.64" to 1.12" (16 mm to 53 mm)
  • Copper 2-hole spade lug compatible with #2 AWG to 1250 kcmil conductors (stranded/compressed) and 400-1250 kcmil solid conductors
  • Non-tracking silicone housing with superior weathering and memory characteristics
  • Shrink-fit design for simplified installation and field-removable center core
  • Supports conductor sizes #2 AWG to 1250 kcmil (stranded/compressed) and 400 kcmil to 1250 kcmil (solid)

Specifications

Application
Cable Termination, Indoor Application, 15kV
Cable Type
Copper Tape Shielded Wire
Color
Gray
Conductor Size
350 to 400 kcmil
Earthing
Products Includes Their Own Grounding System
Mounting
Product Need to have Cable Holder (not included)
Number Of Terminals
(1) Single Phase
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Indoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 300 -Stranded or Compressed 350 Compact or Solid 400.

R2T15J1-N0300

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 300 -Stranded or Compressed 350 Compact or Solid 400.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.

R2IT15M1-N0240

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 270 -Stranded or Compressed 4/0 Compact or Solid 250.

R2IT15J1-N0270

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 270 -Stranded or Compressed 4/0 Compact or Solid 250.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.

R2IT15J1-N0250

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 220 -Stranded or Compressed #2 Compact or Solid #1.

R2IT15J1-N0220

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 220 -Stranded or Compressed #2 Compact or Solid #1.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.

R2IT15J1-N0240

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 440 -Stranded or Compressed 1250 Compact or Solid N/A.

R2T15J4-N0440

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 440 -Stranded or Compressed 1250 Compact or Solid N/A.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 380 -Stranded or Compressed 750 Compact or Solid 900.

R2IT15J4N2380

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 380 -Stranded or Compressed 750 Compact or Solid 900.

Frequently Asked Questions

What is the Coronal Extinction Voltage?

The Coronal Extinction Voltage (Partial Discharge) for the R2IT15 termination is 13 kV (≤ 3pC).

What is the voltage rating of the R2IT15 termination?

The R2IT15 cable termination has a voltage rating of 15 kV.

What cable sizes are compatible with R2IT15 terminations?

The R2IT15 terminations cover cables from #2 AWG through 1250 kcmil, accommodating insulation diameters from 0.64 in (16 mm) to 2.10 in (53 mm).

What is the operating temperature range for R2IT15?

The R2IT15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What is the maximum altitude for R2IT15 installation?

The R2IT15 termination can be installed at a maximum altitude of 3300 feet (1005 m).

What is the IEEE classification for the R2IT15 termination?

The R2IT15 termination has an IEEE Classification of Indoor = Class 2.

What is the power system frequency range?

The R2IT15 termination is designed for power system frequencies ranging from 48 to 62 Hz.

What is the minimum strike distance for R2IT15?

The minimum strike distance for the R2IT15 termination is 8.4 in (213 mm).

What is the creepage distance for the R2IT15?

The creepage distance for the R2IT15 termination is 8.4 in (213 mm).

What is the maximum design voltage to ground?

The maximum design voltage to ground for the R2IT15 termination is 9.5 kV.

How to Install the 15kV Ranger 2 Silicone Rubber Termination for Tape Shielded Cables

This guide provides step-by-step instructions for installing the R2IT15M1N2300 15kV Ranger 2 Shrink fit Silicone Rubber Termination on tape shielded cables for indoor applications. It covers cable preparation, ground braid installation, lug connection, cleaning, and termination placement.

Estimated time: 1h 30m

Tools needed:

Crimping tool, Wire strippers, Measuring tape, Abrasive (aluminum oxide, grit 120 or finer)

Supplies needed:

R2IT15M1N2300 Silicone Rubber Termination Kit, Preformed Ground Braid, Constant Force Spring, Silicone Lubricant, Copper Foil Tape, Gloves, Terminal Lug/Connector, Vinyl Tape, Solvent, Abrasive pads (if needed)

  1. Prepare the Cable for Termination

    WARNING: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products in the work area. Check the cable size against the termination chart. Train the cable into position and cut it to the required length. Prepare the cable according to the specified dimensions (Jacket Removal Length 9-1/4” (235mm), Semi-Con 3/4” (19mm)), allowing for terminal lug depth and aluminum lug growth. Secure the tape shield edge with a single wrap of the supplied copper foil tape to prevent unrolling.

  2. Install the Ground Braid

    Wrap one band of vinyl tape 1/4” (6mm) from the cable jacket end. Position the preformed ground braid with its short tail over the tape shield and the solder block centered over the vinyl tape marker. Secure the ground braid to the cable jacket with vinyl tape. Apply a second vinyl tape band directly over the original marker and ground braid solder block, maintaining the 1/4” (6mm) dimension. Wrap the ground braid around the cable tape shield once, trim any excess, and secure it in place with the constant force spring, wrapping in the same direction. Cinch the spring after the final winding and secure it with two wraps of vinyl tape.

  3. Install the Terminal Lug or Connector

    Verify that the termination assembly will fit over the selected lug. If not, slide the termination onto the cable before installing the lug (do not remove the core yet). Position the connector or lug and crimp it according to the manufacturer's instructions, ensuring not to crimp the last 3/8” to 1/2” of the connector. After crimping, remove any excess oxide inhibitor and all sharp crimp flashings or edges.

  4. Clean the Cable Insulation and Lug Barrel

    Wipe the cable insulation thoroughly with solvent-saturated pads. Exercise caution to prevent the solvent from touching the semi-conductive insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation, avoiding the semi-conductive shield. Ensure that the cable insulation diameter is not reduced below the kit's specifications.

  5. Install the Silicone Rubber Termination Body

    Apply a liberal coating of silicone grease over the edge of the semi-conductive insulation shield to fill the step at the semi-con cut-off. Carefully slide the termination body onto the cable, aligning its edge with the forward edge of the vinyl tape marker. Begin to remove the core slowly, rechecking the termination's position as you proceed. Continue removing the core completely, ensuring not to push or pull on the termination assembly during this process. Finally, connect the ground braid securely to the system ground.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.