ABB - Installation Products R2IT15M1-N0240 - Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.

ABB Installation Products R2IT15M1-N0240 Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/…

UPC: 075114130578


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Cable Termination (SKU: R2IT15M1-N0240) is a 15 kV indoor termination designed for medium-voltage power distribution. This termination utilizes shrink-fit technology to accommodate a wide range of cable insulation diameters from 0.64 inches (16 mm) to 1.12 inches (28 mm). It supports tape shield, wire shield, and unshielded cable types, including popular XLP and EPR constructions. The Ranger2 series is engineered for long-term service in indoor environments. The non-tracking silicone housing offers superior memory and weathering characteristics. Installation is simplified with field-removable center core and common preparation dimensions. Three sizes in the Ranger2 series cover the entire cable range from #2 AWG to 1250 kcmil. The lightning impulse withstand is 110 kV crest. The termination meets IEEE 48 standards. It is rated for ambient temperatures from -22°F to +149°F (-30°C to +65°C) and altitudes up to 3,300 feet (1,005 m). The indoor classification is Class 2 per IEEE, with a minimum strike distance of 8.4 mm and creepage distance of 8.4 mm. This termination can be mounted free hanging or with an optional support bracket. The kit includes the Ranger2 housing, silicone lubricant, and plastic glove. Optional connectors, such as two-hole spade connectors for aluminum conductors ranging from #2 to 1250 kcmil (conductor code 240 for stranded or compressed 1/0 compact or solid 2/0), are available. Optional cable and support brackets are also offered in four sizes. Manufacturer: ABB - Installation Products. SKU: R2IT15M1-N0240.
  • 15 kV voltage rating for medium-voltage applications.
  • Shrink-fit technology for 0.64" - 1.12" insulation diameter range.
  • Accommodates tape shield, wire shield, and unshielded cable types.
  • Non-tracking silicone housing with superior memory and weathering.
  • Rated for -22°F to +149°F (-30°C to +65°C) ambient temperatures.

Specifications

Application
Cable Termination, Indoor Application, 15kV
Cable Type
Copper Tape Shielded Wire
Color
Gray
Conductor Size
1/0 STR AWG , 1/0 COMPR AWG , 2/0 SOL AWG , 2/0 COMPT AWG
Earthing
Products Includes Their Own Grounding System
Mounting
Product Need to have Cable Holder (not included)
Number Of Terminals
(1) Single Phase
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Indoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV, Single Piece Terminator (Class 1), includes Universal Aluminum Rod Contact as standard, Power Cable Termination, Conductor Size - 1/0 Stranded/Compressed or 2/0 Compact/Solid, Use for Insulation Diameter Range from .640 to 1.070 inches.

PCT10240-4

15kV, Single Piece Terminator (Class 1), includes Universal Aluminum Rod Contact as standard, Power Cable Termination, Conductor Size - 1/0 Stranded/Compressed or 2/0 Compact/Solid, Use for Insulation Diameter Range from .640 to 1.070 inches.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 270 -Stranded or Compressed 4/0 Compact or Solid 250.

R2IT15J1-N0270

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 270 -Stranded or Compressed 4/0 Compact or Solid 250.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.

R2IT15J1-N0250

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 220 -Stranded or Compressed #2 Compact or Solid #1.

R2IT15J1-N0220

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 220 -Stranded or Compressed #2 Compact or Solid #1.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.

R2IT15J1-N0240

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 440 -Stranded or Compressed 1250 Compact or Solid N/A.

R2T15J4-N0440

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 440 -Stranded or Compressed 1250 Compact or Solid N/A.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 380 -Stranded or Compressed 750 Compact or Solid 900.

R2IT15J4N2380

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 380 -Stranded or Compressed 750 Compact or Solid 900.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.

R2IT15M1-H0240

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.

Frequently Asked Questions

What is the voltage rating of this termination?

The termination is rated for 15kV applications.

Is this termination suitable for outdoor use?

No, the Ranger2 Termination is rated for indoor use only.

What cable insulation sizes does this termination support?

The termination supports insulation diameters ranging from 0.64 inch to 1.12 inch.

What cable shield types does this termination support?

The termination supports tape shield, wire shield, and unshielded cable configurations.

What conductor sizes are compatible with this termination?

The connector accommodates #2 to 1250 kcmil conductors, including 1/0 compact and 2/0 solid.

How to Install the 15kV Ranger 2 Shrink-Fit Silicone Rubber Termination

This guide outlines the installation process for the 15kV Ranger 2 Shrink-Fit Silicone Rubber Termination (R2IT15M series) for indoor applications. It covers cable preparation, ground braid installation, lug connection, cleaning, and termination body installation for various cable shield types. Note: This indoor kit does not restore a moisture-resistant seal.

Estimated time: 2h

Tools needed:

Crimping tool, Wire strippers, Measuring tape, Utility knife, Solvent applicator pads, Aluminum oxide abrasive (grit 120 or finer, optional)

Supplies needed:

15kV Ranger 2 Shrink-Fit Silicone Rubber Termination kit, Copper foil tape (for tape shield cable), Vinyl tape, Terminal lug or connector, Cleaning solvent, Semi-conductive rubber tape (e.g., Scotch No. 13, if applicable)

  1. Prepare the Cable

    Check your cable size against the Termination Selection Chart (Page 1 of IS-1135) to ensure compatibility. Train the cable into its final position and cut it to the required length for installation. Prepare the cable jacket, semi-con, and insulation according to the specific dimensions provided for your cable type (Tape Shield, Wire Shield, or UniShield®). Ensure you allow for the terminal lug depth and any growth allowance required for aluminum lugs. Safety Warning: Always ensure the cable is completely de-energized before commencing any work.

  2. Install the Ground Braid

    Carefully wrap one band of vinyl tape 1/4” (6mm) from the cable jacket end; this will serve as a crucial marker. Position the preformed ground braid with its short tail over the cable shield (tape shield, shield wires, or UniShield® wires) and center the solder block over the vinyl tape marker. Secure the ground braid to the cable jacket using additional vinyl tape. Apply a second vinyl tape band directly over the original tape marker and ground braid solder block, meticulously maintaining the 1/4” (6mm) dimension. Wrap the ground braid around the cable shield for one complete wrap, trim any excess to prevent overlap, and secure it firmly in place with the constant force spring. Wrap the spring in the same direction as the ground braid and cinch it tightly after the final winding. Secure the constant force spring with two additional wraps of vinyl tape. Note: For cables with cloth or paper semi-conductive insulation shields, it is recommended to overwrap the shield with one half-lapped layer of highly stretched semi-conductive rubber tape (e.g., Scotch® No. 13).

  3. Install the Terminal Lug or Connector

    Before proceeding, verify that the termination assembly will fit over your selected lug. If the lug will not fit through the termination core, clean the insulation and slide the termination body onto the cable *before* installing the lug (do not remove the core at this time). Position the connector or lug and crimp it precisely according to the manufacturer’s instructions. It is critical not to crimp the last 3/8” to 1/2” of the connector. After crimping, meticulously remove any excess oxide inhibitor and all sharp crimp flashings or edges to ensure a smooth surface.

  4. Clean Cable Insulation and Lug Barrel

    Thoroughly wipe the cable insulation with solvent-saturated pads to remove any contaminants. Caution: Do not allow the solvent to touch the semi-conductive insulation shield. If abrasive cleaning is deemed necessary, use it exclusively on the insulation and never on the semi-conductive insulation shield. Employ only aluminum oxide abrasive, grit 120 or finer, and exercise extreme care not to reduce the cable insulation diameter below the minimum allowed by the kit specifications.

  5. Install the Termination Body

    Apply a liberal coating of silicone grease (lubricant) to the edge of the semi-conductive insulation shield (or semi-conductive jacket for UniShield® cables); this silicone is used to fill the step at the semi-con cut-off. Slide the termination body onto the cable. Align the termination edge (or skirt, depending on cable type) with the forward edge of the vinyl tape marker. Carefully begin to remove the core by pulling it counter-clockwise. Recheck the termination position and continue to remove the core steadily. Warning: Do not push or pull on the termination assembly while removing the core, as this can cause damage. Finally, connect the ground braid securely to the system ground.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.