Authorized ABB Distributor (Installation Products)
ABB - Installation Products R2T15J1-N0300 - Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 300 -Stranded or Compressed 350 Compact or Solid 400.

ABB Installation Products R2T15J1-N0300 Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed…

UPC: 783786374151


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB Ranger2 Termination (SKU: R2T15J1-N0300) is a 15 kV outdoor-rated cable termination designed for concentric neutral or jacketed concentric neutral cables with insulation diameters from 0.64 to 1.12 inches. This termination supports conductor sizes ranging from 2 AWG to 1250 kcmil, including stranded, compressed, or solid conductors in 300, 350, or 400 code ranges. The unit features an aluminum 2-hole spade connector (#2-1250 kcmil) for secure, high-current terminations in utility, industrial, and commercial power distribution systems. The Ranger2 series utilizes shrink-fit technology and Elastimold’s pull-down jacket seal feature to deliver a termination line covering the widest range of applications with minimal model variation. Three sizes cover the entire cable range from #2 AWG to 1250 kcmil, accommodating popular XLP and EPR cable types and shield constructions. The non-tracking silicone housing provides superior memory and weathering characteristics, while the field-removable center core enables easy installation in restricted spaces. DC withstand is rated at 15 minutes. Designed for outdoor environments, the Ranger2 termination provides reliable dielectric performance and environmental sealing to protect against moisture, contaminants, and mechanical stress. It is ideal for utility substations, switchgear, transformers, and overhead/underground distribution systems where medium-voltage terminations are required. The aluminum construction ensures corrosion resistance and long-term reliability, while the 2-hole spade connector enables easy installation and secure mechanical fastening.
  • 15 kV outdoor-rated termination for concentric neutral/jacketed concentric neutral cables
  • Supports insulation diameters from 0.64 to 1.12 inches and conductor sizes from 2 AWG to 1250 kcmil
  • Aluminum 2-hole spade connector (#2-1250 kcmil) for secure high-current terminations
  • Non-tracking silicone housing with superior weathering and memory characteristics
  • Field-removable center core for easy installation in restricted spaces

Specifications

Application
Cable Termination, Outdoor Application, 15kV
Cable Type
Concentric Neutral Wire
Color
Gray
Conductor Size
350 to 400 kcmil
Connection Type
2-Hole Spade connector
Current Rating
1250 A
Earthing
Products Includes Their Own Grounding System
Material
Aluminum
Mounting
Product Need to have Cable Holder (not included)
Number Of Terminals
(1) Single Phase
Series
Ranger2
Size
0.64-1.12 inch insulation diameter, 2-1250 kcmil conductor
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84-1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 2 Hole Spade #2-1250kcmil, Stranded or Compressed 350 /Compact or Solid 400. Plated Mild Steel Mounting Bracket 1.10 inch - 1.50 inch (28-38mm)

R2T15J2-N0300-B2

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84-1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 2 Hole Spade #2-1250kcmil, Stranded or Compressed 350 /Compact or Solid 400. Plated Mild Steel Mounting Bracket 1.10 inch - 1.50 inch (28-38mm)
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed #2 /Compact or Solid #1. Stainless Steel Mounting Bracket .80 inch - 1.25 inch (20-32mm)

R2T15J1-T0220-B1

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed #2 /Compact or Solid #1. Stainless Steel Mounting Bracket .80 inch - 1.25 inch (20-32mm)
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed #1 /Compact or Solid 1/0.

R2T15J1-T0230

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed #1 /Compact or Solid 1/0.
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For AL or CU Conductor w/copper wire lead #2 to 4/0. 1/0 Stranded or 2/0 Solid

R2T15J1-T0240

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For AL or CU Conductor w/copper wire lead #2 to 4/0. 1/0 Stranded or 2/0 Solid
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For AL or CU Conductor w/copper wire lead #2 to 4/0. #2 Stranded to #1 Solid

R2T15J1-T0220

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For AL or CU Conductor w/copper wire lead #2 to 4/0. #2 Stranded to #1 Solid
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 2 Hole Spade #2-1250kcmil, Stranded or Compressed 3/0 /Compact or Solid 4/0.

R2T15J1-N0260

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 2 Hole Spade #2-1250kcmil, Stranded or Compressed 3/0 /Compact or Solid 4/0.
Ranger2 Termination for 35KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 400 /Compact or Solid 500, Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch

R2T35J4-N0310-B3

Ranger2 Termination for 35KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 400 /Compact or Solid 500, Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum Barrel For AL Conductor only w/copper wire lead #2 to 4/0. 4/0 Stranded or 250 kcmil Solid

R2T15J1-T1270

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum Barrel For AL Conductor only w/copper wire lead #2 to 4/0. 4/0 Stranded or 250 kcmil Solid

Frequently Asked Questions

What is the Lightning Impulse Withstand Voltage for R2T15?

The Lightning Impulse (BIL Dry 110 Withstand) for the R2T15 is 110 kV Crest.

What is the IEEE classification for the R2T15 outdoor termination?

The R2T15 outdoor termination has an IEEE Classification of Class 1A.

Where can I find installation instructions for R2T15?

Installation instructions are IS-1134 for R2T15J, IS-1135 for R2T15M, and IS-1136 for R2T15L.

What are the mounting options for the R2T15 termination?

The R2T15 termination can be free hanging or mounted using an optional support bracket.

What is the maximum altitude for installing the R2T15?

The R2T15 termination can be installed at a maximum altitude of 3300 feet (1005 m).

What power system frequencies are supported by the R2T15?

The R2T15 termination supports power system frequencies ranging from 48 to 62 Hz.

What is the acceptable ambient temperature range for R2T15?

The R2T15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What is the maximum design voltage to ground for R2T15?

The maximum design voltage to ground for the R2T15 termination is 9.5 kV.

What cable sizes are compatible with the R2T15 termination?

The R2T15 termination accommodates cable sizes from #2 AWG through 1250 kcmil. It is compatible with popular XLP and EPR cable types.

What cable insulation diameters does the R2T15 termination cover?

The R2T15 termination covers cable insulation diameters from 0.64 in (16 mm) to 2.10 in (53 mm).

How to Install the R2T15/28J Cable Termination

This guide provides step-by-step instructions for the safe and proper installation of the 15kV & 28kV Ranger 2 Cable Termination on concentric and jacketed concentric neutral cables for indoor/outdoor applications. Ensure all apparatus are de-energized before starting.

Estimated time: 2h

Tools needed:

Wire strippers, Crimping tool, Approved solvent, Aluminum oxide abrasive (grit 120 or finer, if needed), Vinyl tape or binding wire

Supplies needed:

Silicone Rubber Termination, Lubricant, Grey Silicone Rubber Tape, Sealing Mastic, Gloves, Connector (if not included in kit), Cable Support Bracket (optional)

  1. Perform Initial Checks and De-energize Apparatus

    Before beginning, check the contents of the package to ensure they are complete and undamaged. Verify all components fit properly with the cable and/or mating products. Read the entire installation instructions thoroughly. Gather all required tools and maintain cleanliness throughout the procedure. DANGER: All apparatus must be de-energized during installation or removal of parts. Ensure the circuit is de-energized and follow all local and national work rules.

  2. Prepare the Cable for Termination

    Confirm the cable size fits within the kit's range as shown in the Termination Selection Chart. Train the cable into position and cut it to the required length, allowing sufficient neutral wire length for grounding. Prepare the cable using the dimensions provided in the instructions, accounting for terminal lug depth and additional exposed conductor distance for aluminum lugs. Wrap one band of mastic around the cable jacket 1/4 inch (6mm) from the jacket end, using 50% stretch, and cut it flush without overlap. Bend the neutral wires back over the mastic and secure them to the cable jacket 4-6 inches (100-150mm) from the cut edge using vinyl tape or binding wire. Apply a second mastic band over the neutral wires and the previously applied mastic with 50% stretch, cutting it flush. Finally, wrap two half-lapped layers of vinyl tape around the mastic seal, carefully maintaining the 1/4 inch (6mm) dimension.

  3. Install the Lug or Connector and Clean Cable Insulation

    If using a lug that does not fit through the termination core, clean the insulation and slide the termination onto the cable before installing the lug (do not remove the core at this time). Position the connector or lug and crimp it according to its specific directions, ensuring not to crimp the last 1/4 to 3/8 inch of the connector. Remove any excess oxide inhibitor and sharp crimp flashings after crimping. Wipe the cable insulation with an approved solvent, being careful not to allow the solvent to touch the semi-con insulation shield. If abrasive material is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation, not the semi-con shield, and ensure not to reduce the cable insulation diameter below the kit's allowed range.

  4. Install the Termination Body

    Create a track-resistant moisture seal by wrapping a band of gray silicone rubber tape around the base of the terminal lug. If the barrel diameter is equal to or greater than the cable primary insulation, do not exceed two layers of tape. If the barrel diameter is smaller, build up the tape band to equal the insulation diameter. Apply a liberal coating of silicone grease to the edge of the semi-con insulation shield to fill the step. For lower terminations with a fold-down skirt, pull the loose end of the removable core through the top until it is flush with the bottom of the termination. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully remove the core by unwinding it counter-clockwise, starting with the loose end, ensuring the termination body, not the core, is butted up to the leading edge of the mastic seal. Do not push or pull on the termination assembly while removing the core material.

  5. Complete Sealing and Grounding

    Apply a thin film of silicone lubricant to the skirt and mastic seal area, but do not lubricate the skirt tabs. Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining gray silicone rubber tape, overlapping the termination insulator by approximately 1 inch and extending the tape wrapping over a non-crimped region of the lug/connector barrel with a half-lap configuration. Twist the concentric neutral wires together and connect them securely to the system ground. Finally, confirm that the High-K step does not exceed 1.5 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.