ABB - Installation Products R2IT15J4N2380 - Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 380 -Stranded or Compressed 750 Compact or Solid 900.

ABB Installation Products R2IT15J4N2380 Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed…

UPC: 075114148092


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Termination, identified by SKU R2IT15J4N2380, is a robust indoor termination solution engineered for 15kV electrical systems. This termination is specifically designed to interface with Concentric Neutral and Jacketed Concentric Neutral cable types, providing a secure and reliable connection point. The Ranger2 Termination accommodates a broad insulation diameter range, from a minimum of 1.30 inches to a maximum of 2.10 inches, ensuring versatility across various cable constructions. The integrated connector is a high-quality copper 2-hole spade, meticulously designed to accept conductors ranging from #2 AWG up to 1250 kcmil. Furthermore, the conductor code 380 signifies its compatibility with a specific set of conductor configurations, including stranded or compressed 750 kcmil conductors, as well as solid 900 kcmil conductors. This product is a key component within ABB's comprehensive Installation Products portfolio, contributing to the integrity and performance of electrical infrastructure. UNSPSC Code: 26121648.
  • 15kV Indoor Termination
  • For Concentric Neutral/Jacketed Concentric Neutral Cable
  • Insulation Range: 1.30 inch - 2.10 inch
  • Copper 2-Hole Spade Connector (#2 - 1250 kcmil)
  • Conductor Code 380 (750 kcmil Stranded/Compressed, 900 kcmil Solid)

Specifications

Application
Cable Termination, Indoor Application, 15kV
Cable Type
Concentric Neutral Wire
Color
Gray
Conductor Size
750 to 900 kcmil
Connection Type
Copper 2-Hole Spade #2-1250 kcmil
Earthing
Products Includes Their Own Grounding System
Mounting
Product Need to have Cable Holder (not included)
Mounting Type
Indoor
Number Of Terminals
(1) Single Phase
Series
Ranger2
Size
1.30 inch - 2.10 inch
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Indoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - Tape Shield/Wire Shield/Unshield Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 750 /Compact or Solid 900. - Cable Mounting Bracket - Stainless Steel, 1.45 inch - 1.95 inch (37-50mm)

R2T15M4-N2380-B3

Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - Tape Shield/Wire Shield/Unshield Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 750 /Compact or Solid 900. - Cable Mounting Bracket - Stainless Steel, 1.45 inch - 1.95 inch (37-50mm)
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.

R2IT15M1-H0240

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 260 -Stranded or Compressed 3/0 Compact or Solid 4/0.

R2IT15J1-N0260

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 260 -Stranded or Compressed 3/0 Compact or Solid 4/0.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.

R2IT15J1-H0250

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.
Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 310 -Stranded or Compressed 400 Compact or Solid 500. Cable Mounting Bracket - Stainless Steel, 1.80 inch - 2.40 inch (45-61mm).

R2T35M4-N2310-B4

Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 310 -Stranded or Compressed 400 Compact or Solid 500. Cable Mounting Bracket - Stainless Steel, 1.80 inch - 2.40 inch (45-61mm).
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.

R2IT15J1-H0240

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 310 -Stranded or Compressed 400 Compact or Solid 500. Cable Mounting Bracket - B2 - Stainless Steel - Size 1.10 inch - 1.50 inch.

R2IT15J2-N2310-B2

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 310 -Stranded or Compressed 400 Compact or Solid 500. Cable Mounting Bracket - B2 - Stainless Steel - Size 1.10 inch - 1.50 inch.
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 350 -Stranded or Compressed 650 Compact or Solid 750.

R2T15J4-N0350

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 350 -Stranded or Compressed 650 Compact or Solid 750.

Frequently Asked Questions

What standard does the R2IT15 cable termination meet?

The R2IT15 indoor cable termination meets the IEEE-48 last revision standard.

What is the coronal extinction voltage of this termination?

The coronal extinction voltage (partial discharge) for this termination is 13 kV (≤ 3pC).

What is the maximum design voltage to ground?

The maximum design voltage to ground for the R2IT15 is 9.5 kV.

What is the lightning impulse withstand voltage?

The lightning impulse (BIL Dry) withstand voltage is 110 kV Crest.

What is the 1 minute dry withstand voltage?

The 1 minute dry (60Hz) insulation withstand voltage is 50 kV.

What items are typically included in an R2IT15 kit?

Each kit may contain a Ranger2 Housing, Silicone Lubricant, Plastic Glove, and installation instructions. Optional items like connectors, crimp charts, and support brackets are included if ordered.

Where can I find installation instructions for R2IT15?

Installation instructions are provided with the kit: IS-1134 for R2IT15J, IS-1135 for R2IT15M, and IS-1136 for R2IT15L.

What is the maximum altitude for R2IT15 operation?

The R2IT15 can operate at a maximum altitude of 3300 feet (1005 m).

What is the ambient temperature range for R2IT15?

The R2IT15 operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What cable types are compatible with the R2IT15?

The R2IT15 units accommodate popular XLP and EPR cable types and shield constructions.

How to Install 15kV Ranger 2 Shrink-Fit Silicone Rubber Termination (Indoor)

This guide provides step-by-step instructions for installing the 15kV Ranger 2 Shrink-Fit Silicone Rubber Termination with High-K Stress Relief on tape-shielded cables for indoor applications. It covers cable preparation, ground braid installation, lug connection, cleaning, and termination installation. Ensure all apparatus is de-energized before starting.

Estimated time: 1h 30m

Tools needed:

Cable preparation tools (e.g., utility knife, wire strippers), Crimping tool, Solvent saturated pads, Aluminum oxide abrasive (grit 120 or finer, optional), Measuring tape or ruler

Supplies needed:

15kV Ranger 2 Shrink-Fit Silicone Rubber Termination kit, Preformed Ground Braid, Constant Force Spring, Silicone Lubricant (grease), Copper Foil Tape, Gloves, Vinyl Tape, Terminal lug or connector, System ground connection materials

  1. Prepare Cable

    DANGER: Ensure all apparatus is de-energized before starting installation. Check the cable size against the Termination Selection Chart on Page 1 of the instructions. Train the cable into position and cut it to the required length. Prepare the cable using the dimensions: Jacket Removal Length 9-1/4”(235mm), Semi-Con 1-1/2“(38mm), Tape Shield 3/4”(19mm). Allow for the depth of the terminal lug and additional exposed conductor distance for aluminum lug growth (1/4” to 3/4” depending on size). Prevent the tape shield from unrolling by holding down its edge with a single wrap of the supplied copper foil tape.

  2. Install Ground Braid

    Carefully wrap one band of vinyl tape around the cable jacket 1/4” (6mm) from the jacket end; this tape serves as a marker. Position the preformed ground braid with its short tail over the tape shield and the solder block centered over the vinyl tape strip. Secure the ground braid to the cable jacket using vinyl tape. Apply a second vinyl tape band directly over the original tape marker and ground braid solder block, maintaining the 1/4” (6mm) dimension. Wrap the ground braid around the cable tape shield one complete wrap, trim any excess to prevent overlap, and secure it in place with the constant force spring. Wrap the spring in the same direction as the ground braid. Cinch (tighten) the spring after wrapping the final winding, then secure the spring with two wraps of vinyl tape.

  3. Install Lug or Connector

    Before proceeding, check to ensure the termination assembly fits over your selected lug. If the lug will not fit through the termination core, clean the insulation and slide the termination onto the cable before installing the lug (do not remove the core at this time). Position the connector or lug and crimp it according to the manufacturer’s directions. Do not crimp the last 3/8” to 1/2” of the connector. After crimping, remove any excess oxide inhibitor and all sharp crimp flashings or edges.

  4. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation with solvent saturated pads, being careful not to allow the solvent to touch the semi-con insulation shield. If abrasive must be used, apply it only on the insulation and not on the semi-con insulation shield. Use only aluminum oxide abrasive, grit 120 or finer. Exercise caution to avoid reducing the cable insulation diameter below the limits allowed by the kit.

  5. Install Termination

    Cover the edge of the semi-con insulation shield with a liberal coating of silicone grease; this silicone will fill the step at the semi-con cut-off. Slide the termination body onto the cable and align its edge with the forward edge of the vinyl tape marker. Carefully begin to remove the core by pulling counter-clockwise. Recheck the termination position and continue to remove the core. Do not push or pull on the termination assembly while removing the core. Finally, connect the ground braid to the system ground.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.