ABB - Installation Products R2IT15J2-N0330-B3 - Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 330 -Stranded or Compressed 500, Compact or Solid 600. Cable Mounting Bracket - B3 - Stainless Steel - Size 1.45 inch - 1.95 inch.

ABB Installation Products R2IT15J2-N0330-B3 Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed…

UPC: 075114359856


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB Ranger2 Termination (SKU: R2IT15J2-N0330-B3) is designed for indoor applications, rated for 15kV. It is compatible with Concentric Neutral and Jacketed Concentric Neutral cable types. The insulation range accommodates cables with an outer diameter between .84 inches and 1.38 inches. The termination features an Aluminum 2-Hole Spade connector, suitable for conductors ranging from #2 AWG to 1250 kcmil. For conductor sizing, it supports stranded or compressed conductors from 500 kcmil up to 600 kcmil, and solid conductors up to 600 kcmil (Conductor Code 330). The included Cable Mounting Bracket (B3) is constructed from stainless steel and is sized for cables with an outer diameter between 1.45 inches and 1.95 inches, providing secure cable support. This product is part of the ABB Installation Products line, offering reliable termination solutions for electrical infrastructure. UNSPSC Code: 26121648.
  • 15kV Indoor Termination for Concentric Neutral/Jacketed Concentric Neutral cables
  • Insulation Range: .84 inch - 1.38 inch
  • Aluminum 2-Hole Spade Connector: #2 - 1250 kcmil
  • Conductor Code 330: Supports 500-600 kcmil stranded/compressed, 600 kcmil solid
  • Stainless Steel Cable Mounting Bracket (B3): 1.45 inch - 1.95 inch size

Specifications

Application
Cable Termination, Indoor Application, 15kV
Cable Type
Concentric Neutral Wire
Color
Gray
Conductor Size
500 to 600 kcmil
Connection Type
Concentric Neutral/Jacketed Concentric Neutral
Earthing
Products Includes Their Own Grounding System
Material
Aluminum
Mounting
Product Need to have Cable Holder (not included)
Mounting Type
Stainless Steel Bracket
Number Of Terminals
(1) Single Phase
Series
Ranger2 Termination
Size
1.45 inch - 1.95 inch
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Indoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Indoor Ranger2 Cable Termination. 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range - .64 inch - 1.12 inch. Aluminum 2-Hole Spade #2-1250 kcmil, Conductor 500 Stranded/Compressed or 600 Compact/Solid

R2IT15J1-N0330

Indoor Ranger2 Cable Termination. 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range - .64 inch - 1.12 inch. Aluminum 2-Hole Spade #2-1250 kcmil, Conductor 500 Stranded/Compressed or 600 Compact/Solid
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 280 -Stranded or Compressed 250 kcmil or Compact or Solid 300 kcmil. Cable Mounting Bracket - 1.10 to 1.50 inch (28-38mm).

R2T28M2-N0280-B2

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 280 -Stranded or Compressed 250 kcmil or Compact or Solid 300 kcmil. Cable Mounting Bracket - 1.10 to 1.50 inch (28-38mm).
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 330 -Stranded or Compressed 500 kcmil or Compact or Solid 600 kcmil. Cable Mounting Bracket B4 - 1.80 to 2.40 inch (45-61mm).

R2T28M4-N0330-B4

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 330 -Stranded or Compressed 500 kcmil or Compact or Solid 600 kcmil. Cable Mounting Bracket B4 - 1.80 to 2.40 inch (45-61mm).
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type N0 - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code 410 - Stranded or Compressed 1000.

R2IT15J4N0410

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type N0 - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code 410 - Stranded or Compressed 1000.
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.

R2T28M2-N0240

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.
69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 2, Connection Type 2 - 2 Hole NEMA, Connector Type - Aluminum, Conductor Size Code 30P, Metallic Screen Kit - Flat Braid, Armour Kit - Heat Shrink, No Bracket Required

69TCT222130PABN

69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 2, Connection Type 2 - 2 Hole NEMA, Connector Type - Aluminum, Conductor Size Code 30P, Metallic Screen Kit - Flat Braid, Armour Kit - Heat Shrink, No Bracket Required
69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 3, Connection Type - None, Connector Type - Copper, Conductor Size Code 38P, Metallic Screen Kit - Flat Braid, Armour Kit - Jacketing Tape and Mastic, No Bracket Required

69TCT22N238PANN

69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 3, Connection Type - None, Connector Type - Copper, Conductor Size Code 38P, Metallic Screen Kit - Flat Braid, Armour Kit - Jacketing Tape and Mastic, No Bracket Required
69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 0, Connection Type - None, Connector Type - Copper, Conductor Size Code 32P, Metallic Screen Kit - Flat Braid, Armour Kit - Heat Shrink, No Bracket Required

69TCT20N232PABN

69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 0, Connection Type - None, Connector Type - Copper, Conductor Size Code 32P, Metallic Screen Kit - Flat Braid, Armour Kit - Heat Shrink, No Bracket Required

Frequently Asked Questions

What is the voltage rating of the R2IT15 termination?

The R2IT15 cable termination has a voltage rating of 15 kV. Its maximum design voltage to ground is 9.5 kV.

What cable sizes are compatible with the R2IT15 termination?

The R2IT15 termination accommodates cables with insulation diameters from 0.64 in to 2.10 in, covering #2 AWG through 1250 kcmil. It works with XLP and EPR cable types.

What is the operating temperature range for this termination?

The R2IT15 cable termination is designed to operate within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What is the operating temperature range for this termination?

The R2IT15 cable termination is designed to operate within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What cable sizes are compatible with the R2IT15 termination?

The R2IT15 termination accommodates cables with insulation diameters from 0.64 in to 2.10 in, covering #2 AWG through 1250 kcmil. It works with XLP and EPR cable types.

What is the voltage rating of the R2IT15 termination?

The R2IT15 cable termination has a voltage rating of 15 kV. Its maximum design voltage to ground is 9.5 kV.

What cable sizes are compatible with the R2IT15 termination?

The R2IT15 termination accommodates cables with insulation diameters from 0.64 in to 2.10 in, covering #2 AWG through 1250 kcmil. It works with XLP and EPR cable types.

What is the operating temperature range for this termination?

The R2IT15 cable termination is designed to operate within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What is the voltage rating of the R2IT15 termination?

The R2IT15 cable termination has a voltage rating of 15 kV. Its maximum design voltage to ground is 9.5 kV.

What is the creepage distance for the R2IT15 termination?

The creepage distance for the R2IT15 termination is 8.4 in (213 mm).

How to Install the 15kV Ranger 2 Cable Terminator (R2IT15J)

This guide provides step-by-step instructions for the safe and proper indoor installation of the 15kV Ranger 2 Cable Terminator on concentric and jacketed concentric neutral cables. Ensure all apparatus is de-energized before starting.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Crimping tool, Approved solvent, Aluminum oxide abrasive (optional, grit 120 or finer)

Supplies needed:

15kV Ranger 2 Cable Terminator kit (silicone rubber termination, lubricant, gloves), Compatible connector or lug, Vinyl tape (if applicable for concentric neutral cables), Cable support bracket (optional)

  1. Prepare Cable and Ensure Safety

    DANGER: De-energize all apparatus before starting installation. Verify cable size fits kit range. Train cable into position and cut to length, allowing sufficient neutral wire for grounding. Prepare cable ends using specified dimensions, accounting for lug depth and aluminum lug growth (1/4-3/4 inch). For concentric neutral, bend and secure neutral wires.

  2. Install Lug or Connector

    If using a lug that won't fit through the termination core, clean insulation and slide termination onto cable *before* installing the lug (do not remove core yet). Position and crimp the connector/lug per manufacturer's directions, leaving the last 1/4-3/8 inch uncrimped. Remove excess oxide inhibitor and sharp crimp flashings.

  3. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation with an approved solvent, avoiding contact with the semi-con insulation shield. If abrasive is needed, use only aluminum oxide (grit 120 or finer) on insulation only; do not use on semi-con shield. Ensure cable insulation diameter is not reduced below kit specifications.

  4. Install Termination Body and Ground

    Apply a liberal coating of silicone grease to the edge of the semi-con insulation shield to fill the step. Slide the terminator body onto the cable, aligning its skirt with the cable jacket edge. Carefully remove the core by rotating the lead counter-clockwise while pulling. Do not push or pull the terminator assembly. Twist concentric neutral wires together and connect them securely to the system ground.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.