ABB Installation Products 69TCT20N232PABN 69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 0, Connection…
UPC: 783786399628
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Housing Size 0 configuration for 69kV applications
- Copper connector (code 2) for reliable electrical contact
- Flat braid metallic screen for EMI shielding
- Heat-shrink armour kit for environmental protection
- No bracket required for simplified installation
Specifications
Application | Cable Terminations, 69kV |
Cable Type | Copper Tape Shielded Wire |
Color | Gray |
Conductor Size | 0.746 to 0.780 in |
Connection Type | None |
Earthing | Products Includes Their Own Grounding System |
Material | Copper |
Mounting | No Bracket Required |
Number Of Terminals | (1) Single Phase |
Size | Housing Size 0 |
Special Features | Molded EPDM Elastomer Housing is Durable under Severe Envoronmental Conditions. Lightweight and easy to Handle |
Standard | IEEE 48 and IEC-840 |
Type | Cable Termination |
Voltage Rating | 69 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

69TCT232231PNAN
69kV, Transmission Cable Termination (TCT). Base and Top Module, Housing Size 3, Connection Type 2 - 2 Hole NEMA, Connector Type - Copper, Conductor Size 31P, Metallic Screen Kit - Not Required, Armour Kit - Jacketing Tape and Mastic, No Bracket Required.
69TCT312233PABN
69kV, Transmission Cable Terminator, Base and Two Top Module, Housing Size 1, Connection Type 2 - 2 Hole NEMA, Connector Type - Copper, Conductor Size Code 33P, Metallic Screen Kit - Flat Braid, Armour Kit - Heat Shrink, No Bracket Required
69TCT-222-133P-AAN
69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 2, Connection Type 2 - 2 Hole NEMA, Connector Type - Aluminum, Conductor Size Code 33P, Metallic Screen Kit - Flat Braid, Armour Kit - Jacketing Tape and Mastic, No Bracket Required
69TCT23N242PABN
69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 3, Connection Type - None, Connector Type - Copper, Conductor Size Code 42P, Metallic Screen Kit - Flat Braid, Armour Kit - Heat Shrink, No Bracket Required
69TCT234143PBNN
69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 3, Connection Type 4 - 4 Hole NEMA, Connector Type - Aluminum, Conductor Size Code 43P, Metallic Screen Kit - 1/0 Bonding Cable 6 foot quantity 1 with split Bolts Quantity 2, Armour Kit - not required, No Bracket Required
69TCT312233PAAN
69kV, Transmission Cable Terminator, Base and Two Top Module, Housing Size 1, Connection Type 2 - 2 Hole NEMA, Connector Type - Copper, Conductor Size Code 33P, Metallic Screen Kit - Flat Braid, Armour Kit - Jacketing Tape and Mastic, No Bracket Required
69TCT23N246PAAN
69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 3, Connection Type - None, Connector Type - Copper, Conductor Size Code 46P, Metallic Screen Kit - Flat Braid, Armour Kit - Jacketing Tape and Mastic, No Bracket Required
69TCT234140PAAN
69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 3, Connection Type 4 - 4 Hole NEMA, Connector Type - Aluminum, Conductor Size Code 40P, Metallic Screen Kit - Flat Braid, Armour Kit - Jacketing Tape and Mastic, No Bracket RequiredFrequently Asked Questions
How can I order the 69TCT Terminator?
To order the 69TCT Terminator, provide cable cut sheet information and contact Thomas & Betts at 901-252-5000.
What items are included in each 69TCT Terminator kit?
Each kit contains one TCT Terminator, an instruction sheet, a conductive paint package, and two mastic tapes.
What conductor sizes are compatible with the 69TCT?
The 69TCT Terminator accommodates conductor sizes ranging from 90mm2 (4/0) to 1700mm2 (3500 kcmil).
What cable insulation diameter does the 69TCT accommodate?
The 69TCT Terminator is designed for solid dielectric cables with insulation diameters up to 86.4mm (3.400 inches).
What is the primary application of the 69TCT Terminator?
The 69TCT Terminator provides a Class 1 termination for cable systems rated through 69kV class.
What is the nominal and maximum working voltage?
The nominal voltage is 40kV/59kV, and the maximum working voltage for the 69TCT Terminator is 72.5 kV.
What is the primary application of the 69TCT Terminator?
The 69TCT Terminator provides a Class 1 termination for cable systems rated through 69kV class.
What is the nominal and maximum working voltage?
The nominal voltage is 40kV/59kV, and the maximum working voltage for the 69TCT Terminator is 72.5 kV.
What conductor sizes are compatible with the 69TCT?
The 69TCT Terminator accommodates conductor sizes ranging from 90mm2 (4/0) to 1700mm2 (3500 kcmil).
What cable insulation diameter does the 69TCT accommodate?
The 69TCT Terminator is designed for solid dielectric cables with insulation diameters up to 86.4mm (3.400 inches).
How to Install the ELASTIMOLD TCT Outdoor Transmission Cable Termination
This guide provides step-by-step instructions for the safe and proper installation of the ELASTIMOLD TCT outdoor transmission cable termination, including cable preparation, component assembly, and final mounting. All apparatus must be de-energized during installation, and only competent personnel trained in high-voltage safety practices should perform this procedure.
Estimated time: 3h
Tools needed:
Cable stripping tools, Measuring tape, Hose clamp, Cable cleaner, Sanding tool, Wirebrush, Crimping tool, Soldering iron, Heat gun
Supplies needed:
Spade contact, Semi-conductive paint, Vinyl tape, Lubricant, Mastic, Scintillation ring, #12 AWG copper drain wire, Flat braid, Silicone tape, Mastic tape, Supporting structure hardware
- Perform Pre-Installation Checks and Safety Procedures
Ensure all apparatus is de-energized before starting. Verify the package contents are complete and undamaged, and all components fit properly with the cable. Read the entire instructions, gather all required tools, and maintain cleanliness. This installation must be performed by competent personnel trained in high-voltage safety practices.
- Prepare the Cable End
Straighten the cable and place it in its final position using the spade contact as a guide. Square cut the cable end and note the depth of the spade contact hole (X).
- Remove Outer Jacket and Install Heat Shrink Sleeve
Carefully remove the outer jacket material to a distance of 45.5 inches (111.6 cm) from the cable end to expose the cable shield. Slide the heat shrink sleeve onto the cable.
- Remove Cable Shield
Remove the cable shield to a distance of 43.5 inches (110.5 cm) from the cable end.
- Remove Non-Metallic Screen
Remove the non-metallic screen to a distance of 40 inches (101.5 cm) from the end of the conductor. DO NOT cut or nick the exposed insulation, as this could lead to cable failure. Chamfer the non-metallic screen edge for a minimum of 1/2 inch (1.5 cm).
- Square Cut and Chamfer Cable Insulation
Using a hose clamp as a guide, square cut the cable insulation at X+1 inch from the end of the conductor, being careful not to nick the conductor. Remove the hose clamp. Sand out all nicks and abrasions on the extruded non-metallic screen chamfer and cable insulation. Chamfer the edge of the cable insulation for approximately 3 inches (7.5 cm).
- Clean and Paint Cable Insulation
Using cable cleaner, clean the cable insulation and extruded non-metallic screen, cleaning toward the outer jacket to prevent semi-conductive particles from contaminating the insulation. Place a vinyl tape marker on the cable insulation surface at 39.5 inches (100.5 cm) from the end of the conductor. Stir the supplied semi-conductive paint well. Paint the exposed insulation and a minimum of 1 inch (2.5 cm) of the extruded non-metallic screen with the semi-conductive paint. Remove the vinyl tape within 5 to 15 minutes, ensuring the paint edge is smooth and square. Allow the paint 60 minutes to dry.
- Place Second Vinyl Tape Marker
Place a vinyl tape marker onto the cable non-metallic shield 2 inches (5 cm) from the edge of the paint.
- Assemble Clamps and Winch Assembly
Assemble the Cable Clamp at least 55 inches (140 cm) back from the conductor and tighten it securely. Place the Winch Assembly in front of the Cable Clamp and attach stationary hooks to the Cable Clamp. Attach Adapter Plates to the Housing Clamp with the supplied bolts. Assemble the Housing Clamp around the Terminator Base Section. Extend the steel cable(s) on the Winch Assembly until the hooks reach the Housing Clamp, then hook the cables to the Housing Clamp. Thoroughly lubricate the cable in the specified area and direction with the supplied lubricant.
- Assemble Terminator Base and Module Sections
Assemble the Terminator Base Section on the cable approximately 12 inches from the end. Release tension on each steel cable. Extend the steel cables and Housing Clamp. Position the Terminator Module Section in the Housing Clamp. Install until units overlap and continue assembling mated units until the Terminator Base Section is flush with the tape marker. Remove the Winch Assembly, Housing Clamp, Adapter Plate, and Cable Clamp.
- Connect Conductor and Apply Mastic
Remove the tape marker on the insulation shield. Remove the cut section of insulation on the cable to expose the conductor. Wirebrush the conductor of the cable and immediately insert it into the spade contact. Crimp the connector according to the enclosed crimping instructions, starting at the crimp line and working outward toward the TCT. Remove any excess inhibitor. Apply two layers of mastic: one at the end of the stress cone and one 2 inches (5 cm) back from the end of the cable jacket.
- Install Grounding and Seal Components
Install the scintillation ring and #12 AWG copper drain wire. Solder the flat braid and the #12 drain wire to the shield. Apply a second layer of mastic over the drain wire, on top of the previously applied mastic around the base of the stress cone. Apply a second layer of mastic over the flat braid, on top of the previously applied mastic on the cable jacket. Slide the heat shrink sleeve up to the grounding eye of the base of the terminator. Apply heat to the sleeve, starting in the middle and continuing toward each end of the tube until mastic sealer squeezes from the ends. Connect the flat braid to the system ground. Seal the cable end with mastic tape between the contact and cable insulation. Apply two half-lapped layers of silicone tape covering the crimp connector, mastic tape, and the upper portion of the terminator skirt.
- Mount Terminated Cables to Supporting Structure
Mount the terminated cables to a supporting structure. Ensure that a minimum clearance of 4.0 inches (10 cm) is maintained between the terminator stress cone base and the supporting structure. All apparatus must be installed and operated in accordance with individual user, local, and national work rules.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.