Authorized ABB Distributor (Installation Products)
ABB - Installation Products 69TCT222130PABN - 69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 2, Connection Type 2 - 2 Hole NEMA, Connector Type - Aluminum, Conductor Size Code 30P, Metallic Screen Kit - Flat Braid, Armour Kit - Heat Shrink, No Bracket Required

ABB Installation Products 69TCT222130PABN 69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 2, Connection…

UPC: 783786283781


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 69TCT222130PABN is a 69kV transmission cable terminator designed for high-voltage power distribution systems. This Size 2 terminator features a base and top module design with a 2-pole (2P) configuration, rated for 69kV operation. The aluminum construction ensures corrosion resistance and long-term reliability in outdoor and industrial environments. The 2-hole NEMA connection type provides compatibility with standard NEMA mounting configurations, while the included metallic screen kit (flat braid) and armour kit (heat shrink) enhance grounding and mechanical protection. No additional bracket is required, simplifying installation and reducing labor costs. This terminator is optimized for transmission cable systems where secure, high-voltage terminations are critical for system integrity. The connector type is aluminum, and the conductor size code 30P aligns with medium to large conductor applications. Part of the ABB 69TCT series, this terminator is engineered for utility-grade applications requiring durable, high-voltage cable terminations. The flat braid metallic screen kit ensures proper grounding of the cable sheath, while the heat shrink armour kit provides environmental sealing and mechanical reinforcement. Installation is streamlined due to the absence of a required bracket, making it ideal for retrofits and new installations alike. This product is UNSPSC-coded 26121648, indicating its classification within the electrical transmission and distribution equipment category.
  • 69kV voltage rating for high-voltage transmission applications
  • Size 2 housing with 2-pole (2P) configuration
  • 2-hole NEMA connection type for standard mounting compatibility
  • Aluminum construction with metallic screen (flat braid) and heat shrink armour kit
  • No bracket required, simplifying installation and reducing labor costs

Specifications

Application
Cable Terminations, 69kV
Cable Type
Copper Tape Shielded Wire
Color
Gray
Conductor Size
0.636 to 0.686 in
Earthing
Products Includes Their Own Grounding System
Mounting
No Bracket Required
Number Of Terminals
(1) Single Phase
Special Features
Molded EPDM Elastomer Housing is Durable under Severe Envoronmental Conditions. Lightweight and easy to Handle
Standard
IEEE 48 and IEC-840
Type
Cable Termination
Voltage Rating
69 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
69kV, Transmission Cable Terminator, Base and Two Top Module, Housing Size 2, Connection Type 2 - 2 Hole NEMA, Connector Type - Aluminum, Conductor Size Code 30P, Metallic Screen Kit - Flat Braid, Armour Kit - Heat Shrink, No Bracket Required

69TCT322130PABN

69kV, Transmission Cable Terminator, Base and Two Top Module, Housing Size 2, Connection Type 2 - 2 Hole NEMA, Connector Type - Aluminum, Conductor Size Code 30P, Metallic Screen Kit - Flat Braid, Armour Kit - Heat Shrink, No Bracket Required
69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 3, Connection Type - None, Connector Type - Copper, Conductor Size Code 38P, Metallic Screen Kit - Flat Braid, Armour Kit - Jacketing Tape and Mastic, No Bracket Required

69TCT22N238PANN

69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 3, Connection Type - None, Connector Type - Copper, Conductor Size Code 38P, Metallic Screen Kit - Flat Braid, Armour Kit - Jacketing Tape and Mastic, No Bracket Required
69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 0, Connection Type - None, Connector Type - Copper, Conductor Size Code 32P, Metallic Screen Kit - Flat Braid, Armour Kit - Heat Shrink, No Bracket Required

69TCT20N232PABN

69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 0, Connection Type - None, Connector Type - Copper, Conductor Size Code 32P, Metallic Screen Kit - Flat Braid, Armour Kit - Heat Shrink, No Bracket Required
69kV, Transmission Cable Terminator, Base and Two Top Module, Housing Size 1, Connection Type 2 - 2 Hole NEMA, Connector Type - Copper, Conductor Size Code 33P, Metallic Screen Kit - Flat Braid, Armour Kit - Heat Shrink, No Bracket Required

69TCT312233PABN

69kV, Transmission Cable Terminator, Base and Two Top Module, Housing Size 1, Connection Type 2 - 2 Hole NEMA, Connector Type - Copper, Conductor Size Code 33P, Metallic Screen Kit - Flat Braid, Armour Kit - Heat Shrink, No Bracket Required
69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 2, Connection Type 2 - 2 Hole NEMA, Connector Type - Aluminum, Conductor Size Code 33P, Metallic Screen Kit - Flat Braid, Armour Kit - Jacketing Tape and Mastic, No Bracket Required

69TCT-222-133P-AAN

69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 2, Connection Type 2 - 2 Hole NEMA, Connector Type - Aluminum, Conductor Size Code 33P, Metallic Screen Kit - Flat Braid, Armour Kit - Jacketing Tape and Mastic, No Bracket Required
69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 3, Connection Type - None, Connector Type - Copper, Conductor Size Code 42P, Metallic Screen Kit - Flat Braid, Armour Kit - Heat Shrink, No Bracket Required

69TCT23N242PABN

69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 3, Connection Type - None, Connector Type - Copper, Conductor Size Code 42P, Metallic Screen Kit - Flat Braid, Armour Kit - Heat Shrink, No Bracket Required
69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 3, Connection Type 4 - 4 Hole NEMA, Connector Type - Aluminum, Conductor Size Code 43P, Metallic Screen Kit - 1/0 Bonding Cable 6 foot quantity 1 with split Bolts Quantity 2, Armour Kit - not required, No Bracket Required

69TCT234143PBNN

69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 3, Connection Type 4 - 4 Hole NEMA, Connector Type - Aluminum, Conductor Size Code 43P, Metallic Screen Kit - 1/0 Bonding Cable 6 foot quantity 1 with split Bolts Quantity 2, Armour Kit - not required, No Bracket Required
69kV, Transmission Cable Terminator, Base and Two Top Module, Housing Size 1, Connection Type 2 - 2 Hole NEMA, Connector Type - Copper, Conductor Size Code 33P, Metallic Screen Kit - Flat Braid, Armour Kit - Jacketing Tape and Mastic, No Bracket Required

69TCT312233PAAN

69kV, Transmission Cable Terminator, Base and Two Top Module, Housing Size 1, Connection Type 2 - 2 Hole NEMA, Connector Type - Copper, Conductor Size Code 33P, Metallic Screen Kit - Flat Braid, Armour Kit - Jacketing Tape and Mastic, No Bracket Required

Frequently Asked Questions

What cable insulation diameters does the terminator accommodate?

The terminator accommodates cable insulation diameters up to 86.4mm (3.400 inches).

What standards does the 69TCT Terminator conform to?

The 69TCT Terminator conforms to IEC-840 and IEEE-48 standards.

What items are included in a 69TCT Terminator kit?

Each kit contains one TCT Terminator, one Instruction Sheet, one Conductive Paint Package, and two Mastic Tapes.

Does the 69TCT Terminator require surface oil or grease?

No, the non-tracking polymer housing requires no surface oil or grease to maintain its non-tracking properties.

How do I order the 69TCT Terminator?

To order, provide cable cut sheet information and contact Thomas & Betts at 901-252-5000.

What conductor sizes can the 69TCT Terminator accommodate?

It accommodates conductor sizes from 90mm2 (4/0) to 1700mm2 (3500 kcmil).

What is the nominal voltage of the 69TCT Terminator?

The nominal voltage (Uo/U) for the 69TCT Terminator is 40kV/59kV.

What is the maximum working voltage for this terminator?

The maximum working voltage for the 69TCT Terminator is 72.5 kV.

What is the BIL rating of the 69TCT Terminator?

The Basic Impulse Level (BIL) for the 69TCT Terminator is 350 kV.

What cable systems is the 69TCT Terminator designed for?

The 69TCT Terminator provides a Class 1 termination for cable systems rated through 69kV class. It is designed for solid dielectric cables.

How to Install the ELASTIMOLD TCT Outdoor Transmission Cable Termination

This guide provides detailed instructions for the safe and proper installation of the ELASTIMOLD TCT outdoor transmission cable termination, including cable preparation, component assembly, and final connections.

Estimated time: 4h

Tools needed:

Wire strippers, Utility knife, Hose clamp, Sandpaper, Cable cleaner, Wirebrush, Crimping tool, Heat gun, Soldering iron, Measuring tape, Wrench

Supplies needed:

ELASTIMOLD TCT Termination Kit, Heat shrink sleeve, Semi-conductive paint, Vinyl tape, Lubricant, Cable clamp, Winch assembly, Adapter plates, Housing clamp, Terminator base section, Terminator module section, Spade contact, Mastic, Scintillation ring, #12 AWG copper drain wire, Flat braid, Mastic tape, Silicone tape, Supporting structure (customer supplied)

  1. Prepare for Installation

    DANGER: Ensure all apparatus is de-energized before beginning installation. Verify package contents are complete and undamaged, and all components fit properly with the cable and mating products. Gather all required tools and maintain cleanliness throughout the procedure. This product should only be installed by competent personnel trained in high voltage electrical equipment safety practices.

  2. Straighten and Square Cut Cable

    Straighten the cable and place it in its final position, using the spade contact as a guide. Square cut the cable and note the depth of the spade contact hole (Depth = X).

  3. Remove Outer Jacket and Position Heat Shrink Sleeve

    Carefully remove the outer jacket material to a distance of 45.5 inches (111.6 cm) to expose the cable shield. Slide the heat shrink sleeve onto the cable, positioning it as shown in the diagram.

  4. Remove Cable Shield

    Remove the cable shield to a distance of 43.5 inches (110.5 cm) from the end of the cable.

  5. Remove Non-Metallic Screen and Chamfer Edge

    Remove the non-metallic screen to a distance of 40 inches (101.5 cm) from the end of the conductor. WARNING: Be sure to measure from the end of the conductor, not the end of the insulation. Do not cut or nick the exposed insulation, as this could result in cable failure. Chamfer the non-metallic screen edge for a minimum of 1/2 inch (1.5 cm).

  6. Square Cut and Chamfer Cable Insulation

    Use a hose clamp as a guide to square cut the cable insulation at a distance of X+1 inch from the end of the conductor, being careful not to nick the conductor. Remove the hose clamp. Sand out all nicks and abrasions on the extruded non-metallic screen chamfer and cable insulation. Chamfer the edge of the cable insulation for approximately 3 inches (7.5 cm).

  7. Clean and Apply Semi-Conductive Paint

    Clean the cable insulation and extruded non-metallic screen using cable cleaner, cleaning toward the outer jacket to prevent contamination. Place a vinyl tape marker on the cable insulation surface at 39.5 inches (100.5 cm) from the end. Stir the supplied semi-conductive paint well, then paint the exposed insulation and a minimum of 1 inch (2.5 cm) of the extruded non-metallic screen. Remove the vinyl tape within 5 to 15 minutes, ensuring the paint edge is smooth and square. Allow the paint 60 minutes to dry.

  8. Mark Non-Metallic Shield

    Place a vinyl tape marker onto the cable non-metallic shield 2 inches (5 cm) from the edge of the paint.

  9. Assemble Clamps and Lubricate Cable

    Assemble the Cable Clamp at least 55 inches (140 cm) back from the conductor and tighten it securely. Place the Winch Assembly in front of the Cable Clamp and attach stationary hooks to the Cable Clamp. Attach Adapter Plates to the Housing Clamp with the supplied bolts, then assemble the Housing Clamp around the Terminator Base Section. Extend the steel cable(s) on the Winch Assembly until the hooks reach the Housing Clamp, then hook the cables to the Housing Clamp. Thoroughly lubricate the cable in the specified area and direction with the supplied lubricant; DO NOT SUBSTITUTE.

  10. Assemble Terminator Base and Module Sections

    Assemble the Terminator Base Section on the cable approximately 12 inches from the end. Release tension on each steel cable, then extend the steel cables and Housing Clamp. Position the Terminator Module Section in the Housing Clamp. Install until the units overlap and continue assembling the mated units until the Terminator Base Section is flush with the tape marker. Remove the Winch Assembly, Housing Clamp, Adapter Plate, and Cable Clamp.

  11. Connect Conductor and Apply Mastic

    Remove the tape marker on the insulation shield. Remove the cut section of insulation on the cable to expose the conductor. Wirebrush the conductor and immediately insert it into the spade contact. Crimp the connector according to the enclosed crimping instructions, starting the crimp at the crimp line and working outward toward the TCT. Remove any excess inhibitor. Apply two layers of mastic: one at the end of the stress cone and one 2 inches (5 cm) back from the end of the cable jacket.

  12. Install Scintillation Ring, Drain Wire, and Seal

    Install the scintillation ring and the #12 AWG copper drain wire as shown in the diagram. Solder the flat braid and the #12 drain wire to the shield. Apply a second layer of mastic over the drain wire, on top of the previously applied mastic around the base of the stress cone. Apply a second layer of mastic over the flat braid, on top of the previously applied mastic on the cable jacket. Slide the heat shrink sleeve up to the grounding eye of the base of the terminator. Apply heat to the sleeve, starting in the middle and continuing toward each end until mastic sealer squeezes from the ends. Connect the flat braid to the system ground. Seal the cable end with mastic tape between the contact and cable insulation. Apply two half-lapped layers of silicone tape covering the crimp connector, mastic tape, and the upper portion of the terminator skirt.

  13. Mount Terminated Cables to Supporting Structure

    Mount the terminated cables to a supporting structure, ensuring that a sufficient clearance (minimum 4.0 inches or 10 cm) is maintained between the terminator stress cone base and the supporting structure. Ensure installation complies with individual user, local, and national work rules.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.