ABB Installation Products R2IT15J1-N0380 Indoor Ranger2 Cable Termination. 15kV, Cable Type - Concentric Neutral/Jacketed…
UPC: 075114379571
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15kV voltage rating for medium-voltage applications.
- Compatible with Concentric Neutral and Jacketed Concentric Neutral cable types.
- Accommodates insulation diameters from 0.64 inches to 1.12 inches.
- Features an aluminum 2-hole spade connector.
- Supports conductor sizes 750 kcmil Stranded/Compressed or 900 kcmil Compact/Solid.
Specifications
Application | Cable Termination, Indoor Application, 15kV |
Cable Type | Concentric Neutral Wire |
Color | Gray |
Conductor Size | 750 to 900 kcmil |
Connection Type | 2-Hole Spade |
Connection Type | Concentric Neutral/Jacketed Concentric Neutral |
Current Rating | 1250 A |
Earthing | Products Includes Their Own Grounding System |
Material | Aluminum |
Number Of Terminals | (1) Single Phase |
Series | Ranger2 |
Size | 0.64" - 1.12" |
Size | 0.64 inch - 1.12 inch |
Special Features | Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction |
Standard | IEEE 48 |
Type | Cable Termination - Indoor - Ranger2 |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

R2IT15M4-N0380
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 380 -Stranded or Compressed 750 Compact or Solid 900.
69TCT23NNNNNNBN
69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 3 - Bore Diameter 1.975 inch, Type of Connection - None, Connector Type - None, Conductor Size - None, Metallic Screen Kit - None, Armour Kit - Heat Shrink, No Bracket Required
R2T15M4-N2360-B3
15 kv, Cable Terminator Ranger2, Outdoor, Cable Type - Tape Shield/Wire Shield/UniShield, Insulation Range 4 - 1.30 inch to 2.10 inch (33 mm to 53 mm), Connector Type N2 - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code 360 - Compressed 650/Compact 750, Cable Mounting Bracket B3 - Material Stainless Steel - Size - 1.45 inch to 1.95 inch (37mm - 50mm)
R2T15M4N2360
15 kV, Cable Terminator Ranger2, Outdoor, Cable Type - Tape Shield/Wire Shield/UniShield, Insulation Range 4 - 1.30 inch to 2.10 inch (33 mm to 53 mm), Connector Type N2 - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code 360 - Compressed 650 kcmil or Compact 750 kcmil.
R2IT15J1-N0330
Indoor Ranger2 Cable Termination. 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range - .64 inch - 1.12 inch. Aluminum 2-Hole Spade #2-1250 kcmil, Conductor 500 Stranded/Compressed or 600 Compact/Solid
69TCT322130PABN
69kV, Transmission Cable Terminator, Base and Two Top Module, Housing Size 2, Connection Type 2 - 2 Hole NEMA, Connector Type - Aluminum, Conductor Size Code 30P, Metallic Screen Kit - Flat Braid, Armour Kit - Heat Shrink, No Bracket Required
R2T15J2N0270-B1
Ranger 2 Terminator, Outdoor, 15kV, Concentric Neutral/Jacketed Concentric Neutral Cable Type, Insulation Range .84 -1.38 inch (21-35mm) Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil. 4/0 Stranded/Compressed or 250 kcmil Compact/Solid. Includes Stainless Steel Cable Mounting Bracket Size - 0.80 to 1.25 inch.
R2T35M2-H0250
Outdoor Ranger2 Cable Termination. 35kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - .84 inch - 1.38 inch. Aluminum 1-Hole Spade #2-500 kcmil, Conductor 2/0 Stranded/Compressed AWG or 3/0 Compact/Solid AWGFrequently Asked Questions
What is the minimum strike distance for the R2IT15?
The minimum strike distance for the R2IT15 termination is 8.4 in (213 mm).
What is the Lightning Impulse Withstand (BIL) for R2IT15?
The Lightning Impulse Withstand (BIL Dry) for the R2IT15 termination is 110 kV Crest.
What is the maximum design voltage to ground for R2IT15?
The maximum design voltage to ground for the R2IT15 termination is 9.5 kV.
What is the IEEE classification for the R2IT15 termination?
The R2IT15 termination has an IEEE classification of Indoor = Class 2.
What is the power system frequency range for this product?
The R2IT15 termination is designed for power system frequencies ranging from 48 to 62 Hz.
What is the maximum altitude for R2IT15 installation?
The R2IT15 termination can be installed at a maximum altitude of 3300 feet (1005 m).
What is the ambient temperature range for R2IT15?
The R2IT15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).
What cable sizes are compatible with R2IT15 terminations?
The R2IT15 terminations accommodate cables from #2 AWG through 1250 kcmil, covering insulation diameters from 0.64 in (16 mm) to 2.10 in (53 mm).
What is the voltage rating of the R2IT15 termination?
The R2IT15 cable termination has a voltage rating of 15 kV.
What is the minimum strike distance for the R2IT15?
The minimum strike distance for the R2IT15 termination is 8.4 in (213 mm).
How to Install the 15kV Ranger 2 Cable Terminator (R2IT15J)
This guide provides step-by-step instructions for installing the 15kV Ranger 2 Cable Terminator (R2IT15J) for indoor applications on concentric and jacketed concentric neutral cables. This indoor kit does not restore a moisture-resistant seal; use indoor/outdoor kits if moisture resistance is required.
Estimated time: 1h
Tools needed:
Wire strippers, Measuring tape, Crimping tool, Approved solvent, Aluminum oxide abrasive (grit 120 or finer, if needed)
Supplies needed:
Silicone Rubber Termination, Lubricant, Gloves, Terminal lug or connector, Silicone grease, Vinyl tape, System ground connection materials
- Prepare for Installation and Cable Preparation
Before starting, ensure all apparatus is de-energized. This product must be installed only by competent personnel trained in high voltage electrical equipment safety practices. Check the kit contents and cable size against the Termination Selection Chart. Train the cable into position and cut to the required length, allowing sufficient neutral wire length for grounding. Prepare the cable using the specified dimensions, allowing additional exposed conductor distance for aluminum lug crimping growth. Bend neutral wires back and secure them as instructed, typically with vinyl tape.
- Install Lug or Connector
Ensure the termination assembly fits the chosen lug. If using non-Elastimold lugs that will not fit through the termination core, clean the insulation and slide the termination onto the cable before installing the lug (do not remove the core yet). Position the connector/lug and crimp it according to the manufacturer’s directions, leaving the last 1/4” to 3/8” uncrimped. Remove excess oxide inhibitor and any sharp crimp flashings after crimping.
- Clean Cable Insulation and Lug Barrel
Wipe the cable insulation with an approved solvent, ensuring the solvent does not touch the semi-con insulation shield. If using an abrasive, apply only to the insulation (not the semi-con insulation shield), use aluminum oxide abrasive (grit 120 or finer), and be careful not to reduce the cable insulation diameter below that allowed by the kit.
- Install Termination
Apply a liberal coating of silicone grease to the edge of the semi-con insulation shield to fill the step at the semi-con cut-off. Slide the terminator body onto the cable, aligning the terminator skirt with the edge of the cable jacket. Carefully begin to remove the core by rotating the lead counter-clockwise while pulling. Recheck the terminator position and continue removing the core. Do not push or pull on the terminator assembly during core removal. Twist the concentric neutral wires together and connect them to the system ground.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.