ABB - Installation Products R2IT15M4-N0380 - Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 380 -Stranded or Compressed 750 Compact or Solid 900.

ABB Installation Products R2IT15M4-N0380 Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/…

UPC: 075114202190


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Indoor Termination (SKU: R2IT15M4-N0380) is a high-reliability 15kV cable termination designed for indoor electrical distribution systems. Engineered to IEEE 48 standards, this termination supports cable insulation diameters from 1.30 inches to 2.10 inches, accommodating conductor sizes from #2 AWG to 1250 kcmil. The aluminum 2-hole spade connector ensures secure, low-resistance connections for stranded or compressed conductors up to 750 kcmil (Conductor Code 380) and solid conductors up to 900 kcmil. Compatible with tape shield, wire shield, and unshielded cable types, it provides versatile termination solutions for XLP and EPR cable constructions. The non-tracking silicone housing delivers superior weathering resistance and long-term performance in indoor environments, with optional insulating sleeves available for enhanced creepage and wildlife protection. The shrink-fit housing simplifies installation with common procedures and field-removable center cores, while the compact design allows for restricted-space applications and free-hanging installations. Key electrical ratings include a maximum design voltage to ground of 9.5kV, a coronal extinction voltage of ≤3pC at 13kV, and a lightning impulse withstand of 110kV crest. The termination operates reliably across an ambient temperature range of -22°F to +149°F (-30°C to +65°C) and at altitudes up to 3,300 feet (1,005 meters). Mounting options include free-hanging or optional support brackets, with installation guided by ABB’s IS-1135 instructions. This termination is ideal for utility and industrial power connections requiring secure, insulated termination points in indoor electrical infrastructure.
  • Supports cable insulation diameters from 1.30" to 2.10"
  • Aluminum 2-hole spade connector for #2-1250 kcmil conductors
  • Compatible with tape shield, wire shield, and unshielded cables
  • Non-tracking silicone housing with optional insulating sleeves
  • Compatible with stranded, compressed, and solid conductor configurations.

Specifications

Application
Cable Termination, Indoor Application, 15kV
Cable Type
Copper Tape Shielded Wire
Color
Gray
Conductor Size
750 to 900 kcmil
Connection Type
2-Hole Spade
Current Rating
1250 A
Earthing
Products Includes Their Own Grounding System
Material
Aluminum
Mounting
Product Need to have Cable Holder (not included)
Mounting Type
Indoor
Number Of Terminals
(1) Single Phase
Series
Ranger2
Size
1.30-2.10 inch
Size
1.30 inch - 2.10 inch
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Indoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Indoor Ranger2 Cable Termination. 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range - .64 inch - 1.12 inch. Aluminum 2-Hole Spade #2-1250 kcmil, Conductor 750 Stranded/Compressed or 900 Compact/Solid

R2IT15J1-N0380

Indoor Ranger2 Cable Termination. 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range - .64 inch - 1.12 inch. Aluminum 2-Hole Spade #2-1250 kcmil, Conductor 750 Stranded/Compressed or 900 Compact/Solid
Ranger2 Termination for 15KV indoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Aluminum 2-Hole Spade #2-1250kcmil, Stranded or Compressed 4/0 / Compact or Solid 250.

R2IT15M2N0270

Ranger2 Termination for 15KV indoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Aluminum 2-Hole Spade #2-1250kcmil, Stranded or Compressed 4/0 / Compact or Solid 250.
Ranger2 Termination for 15KV indoor application, cable insulation diameter .84 - 1.38 inches for Tape Shield, Wire Shield, and Unshielded Cable, includes Aluminum 1-Hole Spade connector for 500 kcmil

R2IT15M2-H0250

Ranger2 Termination for 15KV indoor application, cable insulation diameter .84 - 1.38 inches for Tape Shield, Wire Shield, and Unshielded Cable, includes Aluminum 1-Hole Spade connector for 500 kcmil
Ranger2 Termination for 15KV indoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Aluminum 2-Hole Spade #2-1250kcmil, Stranded or Compressed 250 / Compact or Solid 300.

R2IT15M2N0280

Ranger2 Termination for 15KV indoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Aluminum 2-Hole Spade #2-1250kcmil, Stranded or Compressed 250 / Compact or Solid 300.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 300 -Stranded or Compressed 350 Compact or Solid 400.

R2IT15M2-N0300

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 300 -Stranded or Compressed 350 Compact or Solid 400.
Ranger2 Termination for 15KV indoor application, cable insulation diameter .84 - 1.38 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2 to 1250 kcmil. 300 kcmil stranded or 350 kcmil Solid

R2IT15M2-N0290

Ranger2 Termination for 15KV indoor application, cable insulation diameter .84 - 1.38 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2 to 1250 kcmil. 300 kcmil stranded or 350 kcmil Solid
Ranger2 Termination for 15KV indoor application, cable insulation diameter .84 - 1.38 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2 to 1250 kcmil. 400 kcmil Stranded or 500 kcmil Solid

R2IT15M2-N0310

Ranger2 Termination for 15KV indoor application, cable insulation diameter .84 - 1.38 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2 to 1250 kcmil. 400 kcmil Stranded or 500 kcmil Solid
Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 350/ Compact or Solid 400.

R2IT15M1N2300

Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 350/ Compact or Solid 400.

Frequently Asked Questions

What is the voltage rating for the ABB Ranger2 termination?

The ABB Ranger2 termination is rated for 15kV applications.

What cable insulation diameters does this termination support?

This termination supports cable insulation diameters ranging from 1.30 inches to 2.10 inches.

What type of connector does the R2IT15M4-N0380 use?

The R2IT15M4-N0380 features an aluminum 2-hole spade connector.

What conductor sizes are compatible with this termination?

It is compatible with conductor sizes from #2 AWG to 1250 kcmil, including specific codes for stranded, compressed, and solid conductors.

What cable shield types can be used with this termination?

This termination is suitable for tape shield, wire shield, and unshielded cable types.

How to Install the 15kV Ranger 2 Shrink-fit Silicone Rubber Termination (R2IT15M4) on Tape Shielded Cables

This guide provides detailed instructions for installing the 15kV Ranger 2 Shrink-fit Silicone Rubber Termination (R2IT15M4) on tape shielded cables, covering cable preparation, ground braid installation, lug connection, cleaning, and final termination placement. Ensure all safety precautions are followed.

Estimated time: 1h 30m

Tools needed:

Crimping tool, Wire strippers, Cable cutting tool, Soldering iron, Solvent pads, Aluminum oxide abrasive (grit 120 or finer, if needed)

Supplies needed:

15kV Ranger 2 Shrink-fit Silicone Rubber Termination kit, Preformed Ground Braid, Constant Force Spring, Silicone Lubricant, Copper Foil Tape, Gloves, Vinyl Tape, Terminal Lug or Connector

  1. Prepare Cable and Ensure Safety

    DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products. Failure to follow instructions will result in damage and serious injury. This product should be installed only by competent personnel trained in high voltage safety. Check that the cable size fits within the insulation range specified. Train the cable into its final position and cut it to the required length. Prepare the cable by removing the jacket, semi-conductive layer, and insulation according to the dimensions provided, allowing for terminal lug depth and aluminum lug growth allowance. Prevent the tape shield from unrolling by holding its edge with a single wrap of the supplied copper foil tape.

  2. Install Ground Braid

    Wrap one band of vinyl tape around the cable jacket, 1/4 inch (6mm) from the jacket end, to serve as a marker. Position the preformed ground braid with its short tail over the tape shield and the solder block centered over the vinyl tape marker. Secure the ground braid to the cable jacket using vinyl tape. Apply a second vinyl tape band directly over the original tape marker and ground braid solder block, maintaining the 1/4 inch (6mm) dimension. Wrap the ground braid around the cable tape shield one complete wrap, trim any excess to prevent overlap, and secure it in place with the constant force spring. Wrap the spring in the same direction as the ground braid and cinch it after the final winding. Secure the constant force spring with two wraps of vinyl tape.

  3. Install Terminal Lug or Connector

    Verify that the termination assembly will fit over the selected lug. If not, clean the cable insulation and slide the termination onto the cable before installing the lug (do not remove the core at this time). Position the connector or lug and crimp it according to the manufacturer’s directions, ensuring not to crimp the last 3/8 inch to 1/2 inch of the connector. After crimping, remove any excess oxide inhibitor and all sharp crimp flashings or edges.

  4. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation with solvent-saturated pads, taking care not to allow the solvent to touch the semi-conductive insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation only, avoiding the semi-conductive insulation shield. Be careful not to reduce the cable insulation diameter below the kit's allowed specifications.

  5. Install Termination Body

    Apply a liberal coating of silicone grease to the edge of the semi-conductive insulation shield to fill the step at the semi-con cut-off. Slide the termination body onto the cable, aligning its edge with the forward edge of the vinyl tape marker. Carefully begin to remove the core by pulling counter-clockwise. Recheck the termination position and continue removing the core. Do not push or pull on the termination assembly while removing the core. Connect the ground braid to the system ground.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.