ABB - Installation Products R2IT15J1-H0270 - Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 1-Hole Spade #2-500kcmil, Stranded or Compressed 4/0, / Compact or Solid 250.

ABB Installation Products R2IT15J1-H0270 Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12…

UPC: 075114264747


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Termination (SKU: R2IT15J1-H0270) is engineered for reliable 15 kV indoor applications, specifically designed for Concentric Neutral and Jacketed Concentric Neutral cables. This termination accommodates a cable insulation diameter range of 0.64 to 1.12 inches, providing a secure and precise fit for a variety of cable constructions. The connection features a robust aluminum 1-hole spade terminal, compatible with conductor sizes from #2 AWG up to 500 kcmil. This includes support for stranded or compressed conductors in sizes 4/0 AWG, as well as compact or solid 250 kcmil conductors. The Ranger2 series from ABB Installation Products ensures a dependable connection point for critical power distribution systems within indoor environments. Its aluminum construction offers excellent conductivity and corrosion resistance, vital for long-term operational integrity. The 1-hole spade mounting type facilitates straightforward installation onto busbars or equipment terminals. This termination is rated for 15 kV, making it suitable for medium-voltage applications where safety and performance are paramount. The precise sizing for cable insulation diameter ensures proper sealing and electrical insulation, preventing premature failure and maintaining system reliability. For applications requiring a secure and compliant termination for 15 kV indoor power systems, the ABB Ranger2 offers a specification-driven solution.
  • 15 kV voltage rating for indoor medium-voltage applications
  • Accommodates cable insulation diameters from 0.64 to 1.12 inches
  • Aluminum 1-hole spade terminal for #2 AWG to 500 kcmil conductors
  • Compatible with stranded/compressed 4/0 AWG and compact/solid 250 kcmil conductors
  • Designed for Concentric Neutral and Jacketed Concentric Neutral cables

Specifications

Application
Cable Termination, Indoor Application, 15kV
Cable Type
Concentric Neutral Wire
Color
Gray
Conductor Size
4/0 AWG , 250 kcmil
Earthing
Products Includes Their Own Grounding System
Mounting
Product Need to have Cable Holder (not included)
Number Of Terminals
(1) Single Phase
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Indoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV, Single Piece Terminator (Class 1), Two Hole Spade Lug. Power Cable Termination, Conductor Size - 4/0 Stranded/Compressed, Use for Insulation Diameter Range from .640 to 1.070 inches.

PCT10270-3

15kV, Single Piece Terminator (Class 1), Two Hole Spade Lug. Power Cable Termination, Conductor Size - 4/0 Stranded/Compressed, Use for Insulation Diameter Range from .640 to 1.070 inches.
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 750 /Compact or Solid 900.

R2T15J4-N2380

Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 750 /Compact or Solid 900.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 230 -Stranded or Compressed #1, Compact or Solid 1/0.

R2IT15J1-H0230

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 230 -Stranded or Compressed #1, Compact or Solid 1/0.
Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 350/ Compact or Solid 300 .

R2T35M4N2280

Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 350/ Compact or Solid 300 .
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 300 /Compact or Solid 350.

R2T15J2-N2290

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 300 /Compact or Solid 350.
Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 4/0 / Compact or Solid 250.

R2IT15M1N2270

Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 4/0 / Compact or Solid 250.
Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 1-Hole Spade #2-500kcmil, Stranded or Compressed 400, / Compact or Solid 500.

R2IT15J1-H0310

Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 1-Hole Spade #2-500kcmil, Stranded or Compressed 400, / Compact or Solid 500.
Ranger2 Termination, Outdoor, 15kv, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch (21mm-35mm), Connector Type - N2 - Copper 2-Hole Spade #2-1250kcmil, 500 Stranded/Compressed or 600 Compact/Solid, B3 - Cable Mounting Bracket - Stainless Steel - 1.45 inch - 1.95 inch (37-50mm)

R2T15J2-N2330-B3

Ranger2 Termination, Outdoor, 15kv, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch (21mm-35mm), Connector Type - N2 - Copper 2-Hole Spade #2-1250kcmil, 500 Stranded/Compressed or 600 Compact/Solid, B3 - Cable Mounting Bracket - Stainless Steel - 1.45 inch - 1.95 inch (37-50mm)

Frequently Asked Questions

What is the voltage rating of the R2IT15 termination?

The R2IT15 indoor cable termination has a voltage rating of 15 kV. Its maximum design voltage to ground is 9.5 kV.

What is the minimum strike distance for the R2IT15?

The minimum strike distance for the R2IT15 indoor termination is 8.4 in (213 mm).

What is the creepage distance for the R2IT15?

The creepage distance for the R2IT15 indoor termination is 8.4 in (213 mm).

What is the power system frequency range for this product?

The R2IT15 termination operates within a power system frequency range of 48 to 62 Hz.

Does the R2IT15 termination meet any industry standards?

Yes, the R2IT15 indoor cable termination meets the IEEE-48 last revision standard.

What is the maximum altitude for R2IT15 installation?

The R2IT15 termination can be installed at an altitude range of 3300 feet max (1005 m).

What is the operating temperature range for the R2IT15?

The ambient temperature range for the R2IT15 is -22 to +149 °F (-30 to +65 °C).

What cable sizes are compatible with R2IT15 terminations?

The R2IT15 terminations cover insulation diameters from 0.64 in (16 mm) to 2.10 in (53 mm), accommodating #2 AWG through 1250 kcmil cables.

What is the minimum strike distance for the R2IT15?

The minimum strike distance for the R2IT15 indoor termination is 8.4 in (213 mm).

What is the creepage distance for the R2IT15?

The creepage distance for the R2IT15 indoor termination is 8.4 in (213 mm).

How to Install the 15kV Ranger 2 Cable Terminator (Indoor)

This guide provides step-by-step instructions for safely preparing the cable, installing the lug or connector, cleaning the cable insulation, and installing the silicone rubber termination for the 15kV Ranger 2 Cable Terminator for indoor applications.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Crimping tool, Clean cloth (for solvent application), Aluminum oxide abrasive (optional), Gloves

Supplies needed:

Silicone Rubber Termination kit, Lubricant (from kit), Connector (if not included in kit), Silicone grease, Approved solvent, Vinyl tape

  1. De-energize and Prepare Cable

    WARNING: All apparatus must be de-energized during installation. Train the cable into position and cut to the required length. Allow sufficient neutral wire length for grounding. Prepare the cable using the specified dimensions, allowing for terminal lug depth and additional exposed conductor distance for aluminum lugs. Bend neutral wires back and secure them, potentially using vinyl tape as shown in the diagram.

  2. Install and Crimp Lug or Connector

    If using a lug that will not fit through the termination core, clean the insulation and slide the termination onto the cable before installing the lug. Position the connector or lug and crimp it according to the manufacturer's directions, ensuring not to crimp the last 1/4 to 3/8 inch of the connector. After crimping, remove any excess oxide inhibitor and sharp crimp flashings.

  3. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation with an approved solvent, being careful not to let the solvent touch the semi-con insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation only, avoiding the semi-con shield. Ensure the cable insulation diameter is not reduced below the kit's allowed range.

  4. Install Termination Body

    Cover the edge of the semi-con insulation shield with a liberal coating of silicone grease to fill the step at the semi-con cut-off. Slide the terminator body onto the cable, aligning its skirt with the edge of the cable jacket. Carefully begin to remove the core by rotating the lead counter-clockwise while pulling. Recheck the terminator position and continue core removal. Do not push or pull on the terminator assembly during this process.

  5. Connect Neutral Wires to Ground

    Twist the concentric neutral wires together securely and connect them to the system ground to complete the installation.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.