ABB - Installation Products R2IT15J1-H0230 - Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 230 -Stranded or Compressed #1, Compact or Solid 1/0.

ABB Installation Products R2IT15J1-H0230 Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed…

UPC: 075114264730


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Termination, identified by SKU R2IT15J1-H0230, is an indoor-rated termination solution engineered for 15kV electrical systems. This termination is specifically designed to accommodate Concentric Neutral and Jacketed Concentric Neutral cable types. The insulation range supported by this product extends from 0.64 inches to 1.12 inches in outer diameter, ensuring compatibility with a variety of cable sizes. The termination is equipped with an aluminum 1-hole spade connector, suitable for conductor sizes ranging from #2 AWG up to 500 kcmil. For conductor code 230, the Ranger2 Termination is compatible with stranded or compressed #1 AWG conductors, as well as compact or solid 1/0 AWG conductors. This product is a component of ABB's comprehensive Installation Products offering, designed to deliver robust and reliable connections within electrical distribution infrastructure. Its design prioritizes secure termination and effective insulation for medium-voltage cables, fulfilling the stringent demands of indoor installation environments where cable integrity and operational safety are critical. The Ranger2 series is recognized for its user-friendly installation procedures and consistent performance in its designated applications.
  • Indoor 15kV termination for medium-voltage applications
  • Compatible with Concentric Neutral and Jacketed Concentric Neutral cable types
  • Insulation range: 0.64 inch - 1.12 inch
  • Aluminum 1-hole spade connector for #2 - 500 kcmil conductors
  • Supports conductor code 230: #1 AWG stranded/compressed, 1/0 AWG compact/solid

Specifications

Application
Cable Termination, Indoor Application, 15kV
Cable Type
Concentric Neutral Wire
Color
Gray
Conductor Size
#1 STR AWG , #1 COMPR AWG , 1/0 SOL AWG , 1/0 COMPT AWG
Earthing
Products Includes Their Own Grounding System
Mounting
Product Need to have Cable Holder (not included)
Number Of Terminals
(1) Single Phase
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Indoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 230 -Stranded or Compressed #1 Compact or Solid 1/0.

R2T15M1-N0230

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 230 -Stranded or Compressed #1 Compact or Solid 1/0.
Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 350/ Compact or Solid 300 .

R2T35M4N2280

Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 350/ Compact or Solid 300 .
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 300 /Compact or Solid 350.

R2T15J2-N2290

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 300 /Compact or Solid 350.
Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 4/0 / Compact or Solid 250.

R2IT15M1N2270

Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 4/0 / Compact or Solid 250.
Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 1-Hole Spade #2-500kcmil, Stranded or Compressed 400, / Compact or Solid 500.

R2IT15J1-H0310

Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 1-Hole Spade #2-500kcmil, Stranded or Compressed 400, / Compact or Solid 500.
Ranger2 Termination, Outdoor, 15kv, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch (21mm-35mm), Connector Type - N2 - Copper 2-Hole Spade #2-1250kcmil, 500 Stranded/Compressed or 600 Compact/Solid, B3 - Cable Mounting Bracket - Stainless Steel - 1.45 inch - 1.95 inch (37-50mm)

R2T15J2-N2330-B3

Ranger2 Termination, Outdoor, 15kv, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch (21mm-35mm), Connector Type - N2 - Copper 2-Hole Spade #2-1250kcmil, 500 Stranded/Compressed or 600 Compact/Solid, B3 - Cable Mounting Bracket - Stainless Steel - 1.45 inch - 1.95 inch (37-50mm)
Ranger2 Termination, Indoor, 15kv, Cable Type - Tape Shield/WireShield/UniShield, Insulation Range - .64 ich - 1.12 inch (16mm-28mm), Connector Type - N2 - Copper 2-Hole Spade #2-1250kcmil, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid, No Cable Mounting Bracket

R2IT15M1N2220

Ranger2 Termination, Indoor, 15kv, Cable Type - Tape Shield/WireShield/UniShield, Insulation Range - .64 ich - 1.12 inch (16mm-28mm), Connector Type - N2 - Copper 2-Hole Spade #2-1250kcmil, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid, No Cable Mounting Bracket
Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable. Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil. Conductor Code 270 - Stranded 4/0, Solid 250. Cable Mounting Bracket - B2 -Stainless Steel, 1.10-1.50 inches (28-38mm)

R2IT15J1-N0270-B2

Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable. Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil. Conductor Code 270 - Stranded 4/0, Solid 250. Cable Mounting Bracket - B2 -Stainless Steel, 1.10-1.50 inches (28-38mm)

Frequently Asked Questions

What is the voltage rating of the R2IT15 termination?

The R2IT15 cable termination has a voltage rating of 15 kV.

What cable sizes are compatible with R2IT15 terminations?

The R2IT15 terminations accommodate cables from #2 AWG through 1250 kcmil, covering insulation diameters from 0.64 in to 2.10 in.

What is the operating temperature range for the R2IT15?

The R2IT15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What is the maximum altitude for R2IT15 termination installation?

The R2IT15 termination can be installed at a maximum altitude of 3300 feet (1005 m).

What is the IEEE classification for the R2IT15 indoor termination?

The R2IT15 indoor termination has an IEEE Classification of Indoor = Class 2.

What is the power system frequency range for R2IT15?

The R2IT15 termination is designed for power system frequencies ranging from 48 to 62 Hz.

What is the maximum design voltage to ground for R2IT15?

The maximum design voltage to ground for the R2IT15 termination is 9.5 kV.

What is the Lightning Impulse Withstand (BIL Dry) for R2IT15?

The Lightning Impulse Withstand (BIL Dry) for the R2IT15 termination is 110 kV Crest.

What types of cables can the R2IT15 termination accommodate?

The R2IT15 units accommodate popular XLP and EPR cable types and various shield constructions.

What are the mounting options for the R2IT15 termination?

The R2IT15 termination can be free hanging or mounted using an optional support bracket.

How to Install the R2IT15J 15kV Indoor Cable Terminator

This guide provides step-by-step instructions for preparing the cable, installing the lug, and mounting the 15kV Ranger 2 Cable Terminator for indoor applications. Ensure all apparatus is de-energized before starting.

Estimated time: 1h

Tools needed:

Cable stripping tools, Crimping tool, Approved solvent, Aluminum oxide abrasive (optional)

Supplies needed:

Silicone Rubber Termination kit, Silicone lubricant (grease), Gloves, Compatible connector or lug, Grounding wire/connection

  1. De-energize Apparatus and Prepare Work Area

    Before beginning installation, ensure all apparatus is completely de-energized. This product must be installed only by competent personnel trained in high voltage electrical equipment safety practices. Read all instructions and have required tools ready, maintaining cleanliness throughout the procedure.

  2. Prepare Cable Length and Neutral Wires

    Train the cable into its final position and cut it to the required length for installation. Allow sufficient neutral wire length for proper grounding connection. For concentric neutral cables, bend neutral wires back and secure them as instructed.

  3. Strip Cable Insulation and Semi-Conductor Shield

    Prepare the cable according to the dimensions provided in the termination selection chart and diagrams, allowing for the depth of the terminal lug. Carefully remove the cable jacket, neutral wires, and semi-conductor shield. Ensure additional exposed conductor distance is provided for aluminum lugs or connectors to account for growth during crimping.

  4. Install and Crimp Lug or Connector

    If using a lug that will not fit through the termination core, slide the termination body onto the cable before installing the lug (do not remove the core yet). Position the connector or lug onto the prepared conductor and crimp it according to the manufacturer's directions. Do not crimp the last 1/4” to 3/8” of the connector. After crimping, remove any excess oxide inhibitor and sharp crimp flashings.

  5. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation and lug barrel with an approved solvent. Ensure the solvent does not touch the semi-conductor insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (120 grit or finer) on the insulation, avoiding the semi-conductor shield and ensuring the cable insulation diameter is not reduced below kit specifications.

  6. Apply Silicone Grease to Semi-Con Edge

    Liberally coat the edge of the semi-conductor insulation shield with the provided silicone grease. This grease is crucial for filling the step at the semi-conductor cut-off, not as a lubricant for the termination body.

  7. Install Termination Body and Remove Core

    Slide the terminator body onto the cable. Align the terminator skirt with the edge of the cable jacket. Carefully begin to remove the internal core by rotating the lead counter-clockwise while pulling. Recheck the terminator position and continue removing the core. Do not push or pull on the terminator assembly during core removal.

  8. Connect Neutral Wires to System Ground

    Twist the concentric neutral wires together securely and connect them to the system ground according to local and national electrical codes.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.