ABB - Installation Products R2T35M4N2280 - Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 350/ Compact or Solid 300 .

ABB Installation Products R2T35M4N2280 Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38…

UPC: 075114256100


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 R2T35M4N2280 is a robust termination designed for 35KV outdoor applications. This termination is engineered to accommodate a wide range of cable insulation diameters, specifically from 0.84 to 1.38 inches. It offers versatile compatibility with three primary cable types: tape shield, wire shield, and unshielded cables. The R2T35M4N2280 features a copper 2-hole spade connector, suitable for cable sizes ranging from #2 AWG up to 1250 kcmil. This ensures a secure and reliable connection for various conductor configurations, including stranded or compressed conductors from 350 kcmil to 300 kcmil, as well as solid conductors. Manufactured by ABB - Installation Products, this termination provides a critical connection point for high-voltage power distribution systems operating in outdoor environments. Its design prioritizes secure cable termination and electrical integrity for reliable performance. The SKU for this product is R2T35M4N2280. This termination is essential for ensuring the safe and efficient operation of 35KV power infrastructure, offering a dependable solution for connecting power cables to equipment or other distribution lines in exposed conditions. Its construction and material specifications are geared towards long-term serviceability and safety in demanding outdoor settings. The UNSPSC code for this product is 26121648.
  • 35KV outdoor application termination
  • Accommodates cable insulation diameters from 0.84 to 1.38 inches
  • Compatible with tape shield, wire shield, and unshielded cables
  • Copper 2-hole spade connector for #2-1250 kcmil conductors
  • Supports stranded/compressed 350/300 kcmil and solid 300 kcmil conductors

Specifications

Application
Cable Termination, Outdoor Application, 35kV
Cable Type
Copper Tape Shielded Wire
Color
Gray
Conductor Size
250 to 300 kcmil
Earthing
Products Includes Their Own Grounding System
Mounting
Product Need to have Cable Holder (not included)
Number Of Terminals
(1) Single Phase
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 280 -Stranded or Compressed 250 Compact or Solid 300.

R2T28J2-N0280

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 280 -Stranded or Compressed 250 Compact or Solid 300.
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 300 /Compact or Solid 350.

R2T15J2-N2290

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 300 /Compact or Solid 350.
Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 4/0 / Compact or Solid 250.

R2IT15M1N2270

Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 4/0 / Compact or Solid 250.
Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 1-Hole Spade #2-500kcmil, Stranded or Compressed 400, / Compact or Solid 500.

R2IT15J1-H0310

Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 1-Hole Spade #2-500kcmil, Stranded or Compressed 400, / Compact or Solid 500.
Ranger2 Termination, Outdoor, 15kv, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch (21mm-35mm), Connector Type - N2 - Copper 2-Hole Spade #2-1250kcmil, 500 Stranded/Compressed or 600 Compact/Solid, B3 - Cable Mounting Bracket - Stainless Steel - 1.45 inch - 1.95 inch (37-50mm)

R2T15J2-N2330-B3

Ranger2 Termination, Outdoor, 15kv, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch (21mm-35mm), Connector Type - N2 - Copper 2-Hole Spade #2-1250kcmil, 500 Stranded/Compressed or 600 Compact/Solid, B3 - Cable Mounting Bracket - Stainless Steel - 1.45 inch - 1.95 inch (37-50mm)
Ranger2 Termination, Indoor, 15kv, Cable Type - Tape Shield/WireShield/UniShield, Insulation Range - .64 ich - 1.12 inch (16mm-28mm), Connector Type - N2 - Copper 2-Hole Spade #2-1250kcmil, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid, No Cable Mounting Bracket

R2IT15M1N2220

Ranger2 Termination, Indoor, 15kv, Cable Type - Tape Shield/WireShield/UniShield, Insulation Range - .64 ich - 1.12 inch (16mm-28mm), Connector Type - N2 - Copper 2-Hole Spade #2-1250kcmil, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid, No Cable Mounting Bracket
Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable. Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil. Conductor Code 270 - Stranded 4/0, Solid 250. Cable Mounting Bracket - B2 -Stainless Steel, 1.10-1.50 inches (28-38mm)

R2IT15J1-N0270-B2

Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable. Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil. Conductor Code 270 - Stranded 4/0, Solid 250. Cable Mounting Bracket - B2 -Stainless Steel, 1.10-1.50 inches (28-38mm)
Outdoor Ranger2 Cable Termination. 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range - .84 inch - 1.38 inch. Universal Aluminum Barrel for AL or CU Conductor with Copper Wire Lead #2-4/0, Conductor 3/0 Stranded/Compressed or 4/0 Compact/Solid

R2T15J2-T0260

Outdoor Ranger2 Cable Termination. 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range - .84 inch - 1.38 inch. Universal Aluminum Barrel for AL or CU Conductor with Copper Wire Lead #2-4/0, Conductor 3/0 Stranded/Compressed or 4/0 Compact/Solid

Frequently Asked Questions

What cable insulation diameters does this termination support?

This ABB Ranger2 termination supports cable insulation diameters ranging from 0.84 to 1.38 inches.

What types of cables are compatible with this termination?

This termination is compatible with tape shield, wire shield, and unshielded cable types.

What is the conductor size range for the spade connector?

The copper 2-hole spade connector is designed for cable sizes from #2 AWG up to 1250 kcmil.

What are the conductor types supported by this termination?

It supports stranded or compressed conductors from 350 kcmil to 300 kcmil, and solid conductors of 300 kcmil.

What is the voltage rating for this ABB Ranger2 termination?

This termination is rated for 35KV outdoor applications.

How to Install the 35kV Ranger 2 Shrink-fit Silicone Rubber Termination (R2T35M)

This guide provides step-by-step instructions for the safe and proper installation of the 35kV Ranger 2 Shrink-fit Silicone Rubber Termination on high voltage electrical cables, including cable preparation, ground braid installation, and termination application.

Estimated time: 1h 30m

Tools needed:

Crimping tool, Solvent saturated pads, Aluminum oxide abrasive (120 grit or finer, optional), Vinyl tape, Measuring tape, Gloves, Wire strippers

Supplies needed:

35kV Ranger 2 Shrink-fit Silicone Rubber Termination kit (R2T35M), Silicone lubricant, Gray silicone rubber electrical tape, Constant force spring, Preformed ground braid, Sealing mastic, Copper foil tape (for tape shield cables), Terminal lug or connector, Approved solvent

  1. Prepare for Installation and Ensure Safety

    DANGER: De-energize all apparatus in the work area before beginning installation. Do not touch or move energized products. Ensure installation is performed by competent personnel trained in high voltage electrical equipment safety practices. Verify the kit contents are complete and undamaged. Check all components for proper fit with the cable and mating products. Gather all required tools and maintain cleanliness throughout the procedure.

  2. Prepare the Cable

    Confirm the cable size fits within the insulation range specified in the Termination Selection Chart. Train the cable into its final position and cut it to the required length, allowing for the depth of the terminal lug and any growth allowance for aluminum lugs. Remove the cable jacket to the specified length (e.g., 13-1/2 inches (340mm) for tape shield). If using tape shield cable, prevent the tape shield from unrolling by holding down its edge with a single wrap of the supplied copper foil tape. For aluminum lugs, provide additional exposed conductor distance: 1/4 inch (6mm) for 2/0-350 Kcmil, 1/2 inch (13mm) for 400-650 Kcmil, and 3/4 inch (19mm) for 750-1000 Kcmil.

  3. Install the Ground Braid

    Carefully wrap one band of mastic around the cable jacket 1/4 inch (6mm) from the jacket end, using 50% stretch. Cut the mastic flush without overlap. This band also serves as a termination positioning marker. Position the preformed ground braid with the short tail over the tape shield and the solder block centered over the mastic strip. Secure the ground braid to the cable jacket with vinyl tape and press the solder block into the mastic. Apply a second mastic band over the solder block and the first mastic band, maintaining the 1/4 inch (6mm) dimension and using 50% stretch. Cut flush, do not overlap. Wrap two half-lapped layers of vinyl tape around the mastic seal, carefully maintaining the 1/4 inch (6mm) dimension. Wrap the ground braid around the cable tape shield for one complete wrap, trim any excess to prevent overlap, and secure it in place with the constant force spring. Wrap the spring in the same direction as the ground braid, cinch (tighten) it after the final winding, and secure it with two wraps of vinyl tape. SPECIAL NOTE: For cloth or paper semi-con insulation shields, overwrap the shield with one half-lapped layer of highly stretched semi-conductive rubber tape (e.g., Scotch® No. 13).

  4. Install the Terminal Lug or Connector

    Verify that the termination assembly can fit over the selected lug. If not, clean the insulation and slide the termination onto the cable before installing the lug. Do not remove the core at this time. Position the connector or lug and crimp it according to the manufacturer's instructions. Do not crimp the last 3/8 inch to 1/2 inch of the connector. Remove any excess oxide inhibitor and all sharp crimp flashings and edges after crimping.

  5. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation with an approved solvent, ensuring the solvent does not touch the semi-conductive insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation only. Do not use abrasive on the semi-conductive insulation shield. Be careful not to reduce the cable insulation diameter below the kit's allowed range.

  6. Install the Termination Halves

    Create a track-resistant moisture seal between the termination insulator and the lug/connector by wrapping a band of gray silicone rubber electrical tape around the base of the terminal lug. If the barrel diameter is smaller than the cable primary insulation, use the tape strip to build up the band to the insulation diameter. Cover the edge of the semi-conductive insulation shield with a liberal coating of silicone grease to fill the step at the semi-con cut-off. For the lower termination with a fold-down skirt, pull the loose end of the removable core through the top of the termination until the core is flush with the bottom. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully begin to remove the core by unwinding it counter-clockwise, starting with the loose end. Ensure the termination body, not the core, is butted up to the leading edge of the mastic seal. Continue removing the core without pushing or pulling the termination assembly. Using the second housing, carefully pull its core down to within 1 coil of the bottom. Slide this termination over the cable and carefully pull the core counter-clockwise. Overlap the first termination by 1-1/2 inches (40mm). Apply a thin film of silicone lubricant to the skirt and mastic seal area, avoiding the skirt tabs. Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining gray silicone rubber electrical tape. Overlap the termination insulator by approximately 1 inch and extend the tape wrapping over a non-crimped region of the lug/connector barrel with a half-lap configuration.

  7. Connect Ground and Verify

    Connect the ground braid to the system ground. Confirm that the High-K step does not exceed 1.5 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.