
ABB Installation Products R2T15J2-N2290 Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84 - 1.38…
UPC: 075114261456
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15KV outdoor application rating
- Accommodates cable insulation diameters from 0.84 to 1.38 inches
- Designed for Concentric Neutral and Jacketed Concentric Neutral cables
- Copper 2-hole spade for #2 AWG to 1250 kcmil conductors
- Compatible with stranded/compressed (300kcmil+) and compact/solid (350kcmil+) conductors
Specifications
Application | Cable Termination, Outdoor Application, 15kV |
Cable Type | Concentric Neutral Wire |
Color | Gray |
Conductor Size | 300 to 350 kcmil |
Earthing | Products Includes Their Own Grounding System |
Mounting | Product Need to have Cable Holder (not included) |
Number Of Terminals | (1) Single Phase |
Special Features | Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction |
Standard | IEEE 48 |
Type | Cable Termination - Outdoor - Ranger2 |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

R2IT15M2-N0290
Ranger2 Termination for 15KV indoor application, cable insulation diameter .84 - 1.38 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2 to 1250 kcmil. 300 kcmil stranded or 350 kcmil Solid
R2IT15M1N2270
Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 4/0 / Compact or Solid 250.
R2IT15J1-H0310
Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 1-Hole Spade #2-500kcmil, Stranded or Compressed 400, / Compact or Solid 500.
R2T15J2-N2330-B3
Ranger2 Termination, Outdoor, 15kv, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch (21mm-35mm), Connector Type - N2 - Copper 2-Hole Spade #2-1250kcmil, 500 Stranded/Compressed or 600 Compact/Solid, B3 - Cable Mounting Bracket - Stainless Steel - 1.45 inch - 1.95 inch (37-50mm)
R2IT15M1N2220
Ranger2 Termination, Indoor, 15kv, Cable Type - Tape Shield/WireShield/UniShield, Insulation Range - .64 ich - 1.12 inch (16mm-28mm), Connector Type - N2 - Copper 2-Hole Spade #2-1250kcmil, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid, No Cable Mounting Bracket
R2IT15J1-N0270-B2
Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable. Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil. Conductor Code 270 - Stranded 4/0, Solid 250. Cable Mounting Bracket - B2 -Stainless Steel, 1.10-1.50 inches (28-38mm)
R2T15J2-T0260
Outdoor Ranger2 Cable Termination. 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range - .84 inch - 1.38 inch. Universal Aluminum Barrel for AL or CU Conductor with Copper Wire Lead #2-4/0, Conductor 3/0 Stranded/Compressed or 4/0 Compact/Solid
R2T35M2H0220
Outdoor Ranger2 Cable Termination. 35kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - .84 inch - 1.38 inch. Aluminum 1-Hole Spade #2-500 kcmil, Conductor #2 Stranded/Compressed or #1 Compact/SolidFrequently Asked Questions
What is the IEEE classification for the R2T15?
The R2T15 termination has an IEEE Classification of Outdoor = Class 1A.
Where can I find installation instructions for R2T15?
Installation instructions are IS-1134 for R2T15J, IS-1135 for R2T15M, and IS-1136 for R2T15L.
What is the power system frequency range for R2T15?
The R2T15 termination is designed for power system frequencies ranging from 48 to 62 Hz.
What is the minimum strike distance for the R2T15?
The R2T15 termination has a minimum strike distance of 11.4 inches (381 mm).
What is the creepage distance for the R2T15?
The R2T15 termination has a creepage distance of 15.0 inches (381 mm).
What is the maximum altitude for R2T15 installation?
The R2T15 termination can be installed at a maximum altitude of 3300 feet (1005 meters).
What is the operating temperature range for the R2T15?
The R2T15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).
What is the voltage rating of the R2T15 termination?
The R2T15 termination has a voltage rating of 15 kV. Its maximum design voltage to ground is 9.5 kV.
What cable sizes does the R2T15 termination support?
The R2T15 termination supports insulation diameters from 0.64 inches to 2.10 inches, covering #2 AWG through 1250 kcmil cables.
What is the IEEE classification for the R2T15?
The R2T15 termination has an IEEE Classification of Outdoor = Class 1A.
How to Install the 15kV Ranger 2 Cable Termination (R2T15J2)
This guide provides step-by-step instructions for preparing the cable, installing the lug or connector, cleaning the cable insulation, and installing the silicone rubber termination for 15kV Ranger 2 cable terminations for indoor/outdoor applications.
Estimated time: 1h 30m
Tools needed:
Wire strippers, Crimping tool, Approved solvent applicator, Aluminum oxide abrasive (grit 120 or finer, if needed), Knife or cable stripping tools
Supplies needed:
Silicone Rubber Termination, Lubricant, Grey Silicone Rubber Tape, Sealing Mastic, Gloves, Connector (optional), Vinyl tape or binding wire, Approved solvent, Silicone grease
- Prepare the Cable
DANGER: All apparatus must be de-energized during installation. Verify the cable size fits within the kit range using the Termination Selection Chart. Train the cable into position and cut to the required length, ensuring sufficient neutral wire length for grounding. Prepare the cable using the specified dimensions, allowing for terminal lug depth and additional exposed conductor distance for aluminum lug crimping. Carefully wrap one band of sealing mastic around the cable jacket 1/4 inch (6mm) from the jacket end, using a 50% stretch. Cut mastic flush without overlapping. Bend the neutral wires back over the mastic, press them into the seal, and secure them to the cable jacket 4-6 inches (100-150mm) from the cut edge using vinyl tape or binding wire. Apply a second mastic band over the neutral wires and the previously applied mastic, using a 50% stretch, and cut flush. Finally, wrap two half-lapped layers of vinyl tape around the mastic seal, maintaining the 1/4 inch (6mm) dimension.
- Install the Lug or Connector
If using lugs that will not fit through the termination core, clean the insulation and slide the termination onto the cable before installing the lug (do not remove the core at this time). Position the connector/lug and crimp it according to its specific directions. Do not crimp the last 1/4 inch to 3/8 inch of the connector. After crimping, remove any excess oxide inhibitor and sharp crimp flashings.
- Clean Cable Insulation and Lug Barrel
Wipe the cable insulation with an approved solvent, ensuring the solvent does not touch the semi-con insulation shield. If an abrasive is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation only; do not use it on the semi-con insulation shield. Exercise caution to avoid reducing the cable insulation diameter below the kit's allowed range.
- Install the Termination Body
Create a track-resistant moisture seal by wrapping a band of gray silicone rubber tape around the base of the terminal lug. Adjust the number of tape layers based on whether the barrel diameter is equal to or greater than the cable primary insulation, or smaller. Cover the edge of the semi-con insulation shield with a liberal coating of silicone grease to fill the step at the semi-con cut-off. For lower terminations with a fold-down skirt, pull the loose end of the removable core through the top of the termination until it is flush with the bottom. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully remove the core by unwinding it counter-clockwise, starting with the loose end. Ensure the termination body, not the core, is butted up to the leading edge of the mastic seal. Do not push or pull on the termination assembly while removing the core material.
- Complete Termination Sealing and Grounding
Apply a thin film of silicone lubricant to the skirt and mastic seal area, but do not lubricate the skirt tabs. Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining gray silicone rubber tape, overlapping the termination insulator by approximately 1 inch and extending the tape wrapping over a non-crimped region of the lug/connector barrel with a half-lap configuration. Twist the concentric neutral wires together and connect them securely to the system ground. Finally, confirm that the High-K step does not exceed 1.5 inches.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.