ABB - Installation Products R2IT15M1N2220 - Ranger2 Termination, Indoor, 15kv, Cable Type - Tape Shield/WireShield/UniShield, Insulation Range - .64 ich - 1.12 inch (16mm-28mm), Connector Type - N2 - Copper 2-Hole Spade #2-1250kcmil, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid, No Cable Mounting Bracket

ABB Installation Products R2IT15M1N2220 Ranger2 Termination, Indoor, 15kv, Cable Type - Tape Shield/WireShield/UniShield…

UPC: 075114280372


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Termination (SKU: R2IT15M1N2220) is a field-proven, indoor-rated termination designed for 15kV cable systems with tape shield, WireShield, or UniShield constructions. It accommodates cable insulation diameters from 0.64 inch to 1.12 inch (16mm to 28mm) and supports conductor sizes from #2 stranded/compressed to #1 compact/solid, terminating to a copper N2 2-hole spade connector rated for 2-1250kcmil applications. This termination kit eliminates the need for a separate cable mounting bracket, simplifying installation while maintaining mechanical integrity. The N2 connector design ensures secure, low-resistance electrical contact for high-current applications, reducing heat buildup and improving system reliability. Compatible with common shielded medium-voltage cable types, the Ranger2 termination is optimized for indoor substations, switchgear, and industrial power distribution systems where space constraints and performance consistency are critical. Key benefits include reduced installation time due to integrated components, consistent performance across specified conductor ranges, and compatibility with industry-standard shielded cable designs. The termination’s design aligns with ABB’s Ranger2 system, ensuring compatibility with other Ranger2 accessories for modular, scalable solutions in medium-voltage networks.
  • Rated for 15kV indoor applications with tape shield, WireShield, or UniShield cable constructions
  • Accommodates 16mm to 28mm insulation diameter and #2 stranded or #1 compact/solid conductors
  • N2 copper 2-hole spade connector for 2-1250kcmil terminations
  • No separate cable mounting bracket required, simplifying installation
  • Compatible with ABB Ranger2 system for modular medium-voltage solutions

Specifications

Application
Cable Termination, Indoor Application, 15kV
Cable Type
Copper Tape Shielded Wire
Color
Gray
Conductor Size
#2 STR AWG , #2 COMPR AWG , #1 SOL AWG , #1 COMPT AWG
Earthing
Products Includes Their Own Grounding System
Mounting
Product Need to have Cable Holder (not included)
Number Of Terminals
(1) Single Phase
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Indoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV, Single Piece Terminator (Class 1), One-Hole Spade Lug. Power Cable Termination, Conductor Size - #2 Stranded/Compressed or #1 Compact/Solid, Use for Insulation Diameter Range from .640 to 1.070 inches.

PCT10220-5

15kV, Single Piece Terminator (Class 1), One-Hole Spade Lug. Power Cable Termination, Conductor Size - #2 Stranded/Compressed or #1 Compact/Solid, Use for Insulation Diameter Range from .640 to 1.070 inches.
Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable. Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil. Conductor Code 270 - Stranded 4/0, Solid 250. Cable Mounting Bracket - B2 -Stainless Steel, 1.10-1.50 inches (28-38mm)

R2IT15J1-N0270-B2

Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable. Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil. Conductor Code 270 - Stranded 4/0, Solid 250. Cable Mounting Bracket - B2 -Stainless Steel, 1.10-1.50 inches (28-38mm)
Outdoor Ranger2 Cable Termination. 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range - .84 inch - 1.38 inch. Universal Aluminum Barrel for AL or CU Conductor with Copper Wire Lead #2-4/0, Conductor 3/0 Stranded/Compressed or 4/0 Compact/Solid

R2T15J2-T0260

Outdoor Ranger2 Cable Termination. 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range - .84 inch - 1.38 inch. Universal Aluminum Barrel for AL or CU Conductor with Copper Wire Lead #2-4/0, Conductor 3/0 Stranded/Compressed or 4/0 Compact/Solid
Outdoor Ranger2 Cable Termination. 35kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - .84 inch - 1.38 inch. Aluminum 1-Hole Spade #2-500 kcmil, Conductor #2 Stranded/Compressed or #1 Compact/Solid

R2T35M2H0220

Outdoor Ranger2 Cable Termination. 35kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - .84 inch - 1.38 inch. Aluminum 1-Hole Spade #2-500 kcmil, Conductor #2 Stranded/Compressed or #1 Compact/Solid
Indoor Ranger2 Cable Termination. 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range - .64 inch - 1.12 inch. Aluminum 2-Hole Spade #2-1250 kcmil, Conductor 350 Stranded/Compressed or 400 Compact/Solid

R2IT15J1-N0300

Indoor Ranger2 Cable Termination. 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range - .64 inch - 1.12 inch. Aluminum 2-Hole Spade #2-1250 kcmil, Conductor 350 Stranded/Compressed or 400 Compact/Solid
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 300 -Stranded or Compressed 350 Compact or Solid 400.

R2IT15M1-N0300

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 300 -Stranded or Compressed 350 Compact or Solid 400.
Outdoor, Ranger2 Termination, 35kV, Tape Shield/Wire Shield/UniShield Cable Type, Insulation Range - .84-1.38 inch (21-35mm). Connector Type Copper 2-Hole Spade #2-1250 kcmil. Conductor - 2/0 Stranded/Compressed or 3/0 Compact/Solid. Cable Mounting Bracket Material - Stainless Steel, Size 1.10-1.50 inch (28-38mm).

R2T35M2N2250-B2

Outdoor, Ranger2 Termination, 35kV, Tape Shield/Wire Shield/UniShield Cable Type, Insulation Range - .84-1.38 inch (21-35mm). Connector Type Copper 2-Hole Spade #2-1250 kcmil. Conductor - 2/0 Stranded/Compressed or 3/0 Compact/Solid. Cable Mounting Bracket Material - Stainless Steel, Size 1.10-1.50 inch (28-38mm).
Outdoor Ranger2 Cable Termination. 35kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - .84 inch - 1.38 inch. Universal Aluminum Barrel for AL or CU Conductor with Copper Wire Lead #2-4/0, Conductor 1/0 Stranded/Compressed or 2/0 Compact/Solid

R2T35M2T0240

Outdoor Ranger2 Cable Termination. 35kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - .84 inch - 1.38 inch. Universal Aluminum Barrel for AL or CU Conductor with Copper Wire Lead #2-4/0, Conductor 1/0 Stranded/Compressed or 2/0 Compact/Solid

Frequently Asked Questions

What is the creepage distance of the R2IT15?

The creepage distance for the R2IT15 termination is 8.4 in (213 mm).

Where can I find installation instructions for R2IT15?

Installation instructions are available as IS-1134 for R2IT15J, IS-1135 for R2IT15M, and IS-1136 for R2IT15L.

What is included in an R2IT15 termination kit?

Each kit may contain a Ranger2 Housing, silicone lubricant, a plastic glove, and optionally a connector, crimp chart, and support bracket if ordered.

What power system frequencies does the R2IT15 support?

The R2IT15 termination is designed to operate with power system frequencies ranging from 48 to 62 Hz.

What is the maximum altitude for R2IT15 installation?

The R2IT15 termination can be installed at an altitude range of up to 3300 feet (1005 m) maximum.

What is the operating temperature range for R2IT15?

The R2IT15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What cable types are supported by the R2IT15?

The R2IT15 units accommodate popular XLP and EPR cable types, along with various shield constructions.

What cable sizes are compatible with R2IT15 terminations?

The R2IT15 terminations accommodate cables from #2 AWG through 1250 kcmil, covering insulation diameters from 0.64 in (16 mm) to 2.10 in (53 mm).

What is the voltage rating of the R2IT15 termination?

The R2IT15 cable termination has a voltage rating of 15 kV. It also has a maximum design voltage to ground of 9.5 kV.

What is the creepage distance of the R2IT15?

The creepage distance for the R2IT15 termination is 8.4 in (213 mm).

How to Install the 15kV Ranger 2 Indoor Silicone Rubber Termination

This guide provides detailed instructions for installing the 15kV Ranger 2 Shrink Fit Silicone Rubber Termination for indoor applications, covering cable preparation, ground braid installation, and final termination placement.

Estimated time: 1h 30m

Tools needed:

Cable knife, Wire strippers, Measuring tape, Crimping tool, Solvent applicator, Abrasive applicator (if needed)

Supplies needed:

15kV Ranger 2 Shrink Fit Silicone Rubber Termination Kit, Vinyl tape, Copper foil tape (for tape shield cables), Cable connector/lug, Oxide inhibitor, Cleaning solvent, Cleaning pads, Aluminum oxide abrasive (grit 120 or finer, if needed), Semi-conductive rubber tape (if cloth or paper semi-con insulation shield)

  1. Review Safety and Prepare for Installation

    DANGER: Ensure all apparatus is de-energized before beginning installation or removal of any parts. Do not touch or move energized products. This product must be installed by competent personnel trained in high voltage electrical equipment safety. Read the entire installation instructions before starting. Inspect all kit components for damage, proper rating, and compatibility with mating parts. Gather all required tools and supplies, and maintain cleanliness throughout the procedure.

  2. Prepare the Cable

    Verify the cable size fits within the insulation range specified in the Termination Selection Chart. Train the cable into its final position and cut it to the required length, allowing for the terminal lug depth and any growth allowance for aluminum lugs. Remove the cable jacket for 9-1/4 inches (235mm). For tape shield cables, prevent the tape shield from unrolling by holding down its edge with a single wrap of the supplied copper foil tape. For wire shield cables, bend the exposed shield wires back upon themselves to the jacket edge, leaving 1 inch (25mm) exposed. For UniShield® cables, follow specific instructions for shield wire and semi-conductive jacket removal.

  3. Install the Ground Braid

    Wrap one band of vinyl tape around the cable jacket 1/4 inch (6mm) from the jacket end; this serves as a marker. Position the preformed ground braid with its short tail over the cable shield (tape shield, wire shield, or UniShield® wires) and center the solder block over the vinyl tape marker. Secure the ground braid to the cable jacket using vinyl tape. Apply a second vinyl tape band directly over the original marker and ground braid solder block, carefully maintaining the 1/4 inch (6mm) dimension. Wrap the ground braid around the cable shield for one complete wrap, trim any excess to prevent overlap, and secure it in place with the constant force spring, wrapping the spring in the same direction as the ground braid. Cinch the spring after the final winding and secure it with two wraps of vinyl tape. If working with cloth or paper semi-conductive insulation shields, overwrap the shield with one half-lapped layer of highly stretched semi-conductive rubber tape.

  4. Install the Lug or Connector

    Before proceeding, check that the termination assembly will fit over the selected lug. If the lug will not fit through the termination core, clean the insulation and slide the termination onto the cable *before* installing the lug (do not remove the core at this time). Position the connector or lug and crimp it according to the manufacturer's directions. Do not crimp the last 3/8 inch to 1/2 inch of the connector. After crimping, remove any excess oxide inhibitor and all sharp crimp flashings or edges.

  5. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation thoroughly with solvent-saturated pads. Exercise caution to prevent the solvent from touching the semi-conductive insulation shield. If abrasive cleaning is necessary, use it only on the insulation and not on the semi-conductive insulation shield. Use only aluminum oxide abrasive, grit 120 or finer, and be careful not to reduce the cable insulation diameter below the kit's specified allowance.

  6. Install the Termination Body

    Apply a liberal coating of silicone grease to the edge of the semi-conductive insulation shield; this silicone will fill the step at the semi-con cut-off. Slide the termination body onto the cable, aligning its edge (or skirt for wire shield/Unishield) with the forward edge of the vinyl tape marker. Carefully begin to remove the core by pulling counter-clockwise. Continuously recheck the termination's position as you remove the core. Do not push or pull on the termination assembly while removing the core.

  7. Connect Ground Braid

    Connect the installed ground braid securely to the system ground.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.