ABB - Installation Products R2T15M1-N0230 - Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 230 -Stranded or Compressed #1 Compact or Solid 1/0.

ABB Installation Products R2T15M1-N0230 Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/…

UPC: 075114130516


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Termination (SKU: R2T15M1-N0230) is a 15kV outdoor cable termination designed for medium-voltage power distribution systems. This termination supports cable insulation diameters from 0.64 inch (16 mm) to 2.10 inch (53 mm), accommodating conductor sizes from #2 AWG through 1250 kcmil. It is compatible with tape shield, wire shield, or unshielded cable configurations, including XLP and EPR insulation types. Key features include a non-tracking silicone housing with superior weathering resistance and memory characteristics, ensuring long-term performance in outdoor environments. The shrink-fit housing design simplifies installation with common procedures and field-removable center core for easy access. The termination includes four sheds for enhanced creepage and strike distances, meeting 15kV outdoor service requirements. Electrical ratings include a maximum design voltage to ground of 9.5 kV, a coronal extinction voltage of ≤3 pC at 13 kV, and a lightning impulse withstand of 110 kV crest. It also withstands 45 kV for 10 seconds wet (60Hz), 50 kV for 1 minute dry (60Hz), and 35 kV for 5 hours dry (60Hz). The DC withstand rating is 15 minutes. The termination is designed for use in utility power lines, renewable energy projects, industrial facilities, and substations requiring reliable 15kV terminations. Optional connectors include copper stem, one-hole, and two-hole spade connectors (#2-1250 kcmil), with support brackets available in four sizes (0.80-2.40 inch O.D.). The pull-down jacket seal feature ensures secure installation in restricted spaces or free-hanging applications. Insulating silicone sleeves are available for additional creepage or wildlife protection needs.
  • 15kV outdoor termination for medium-voltage applications
  • Supports 0.64-2.10" insulation diameter and #2-1250 kcmil conductors
  • Compatible with tape shield, wire shield, or unshielded cables (XLP/EPR)
  • Non-tracking silicone housing with 4 sheds for enhanced creepage
  • Shrink-fit design with field-removable center core for easy installation

Specifications

Application
Cable Termination, Outdoor Application, 15kV
Cable Type
Copper Tape Shielded Wire
Color
Gray
Conductor Size
#1 STR AWG , #1 COMPR AWG , 1/0 SOL AWG , 1/0 COMPT AWG
Connection Type
2-Hole Spade Connector (#2-1250 kcmil)
Current Rating
1250 kcmil
Earthing
Products Includes Their Own Grounding System
Material
Aluminum
Mounting
Product Need to have Cable Holder (not included)
Number Of Terminals
(1) Single Phase
Series
Ranger2
Size
0.64-1.12 inches (insulation diameter)
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV, Single Piece Terminator (Class 1), includes Universal Aluminum Rod Contact as standard, Power Cable Termination, Conductor Size - #1 Stranded/Compressed or 1/0 Compact/Solid, Use for Insulation Diameter Range from .640 to 1.070 inches.

PCT10230-4

15kV, Single Piece Terminator (Class 1), includes Universal Aluminum Rod Contact as standard, Power Cable Termination, Conductor Size - #1 Stranded/Compressed or 1/0 Compact/Solid, Use for Insulation Diameter Range from .640 to 1.070 inches.
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 0.64 - 1.12 inches for Cable Type - Tape Shield/Wire Shield/ UniShield. includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 4/0/ Compact or Solid 250.

R2T15M1-N0270

Ranger2 Termination for 15KV outdoor application, cable insulation diameter 0.64 - 1.12 inches for Cable Type - Tape Shield/Wire Shield/ UniShield. includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 4/0/ Compact or Solid 250.
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 210 -Stranded or Compressed N/A Compact or Solid #2.

R2T15M1-N0210

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 210 -Stranded or Compressed N/A Compact or Solid #2.
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 220 -Stranded or Compressed #2 Compact or Solid #1.

R2T15M1-H0220

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 220 -Stranded or Compressed #2 Compact or Solid #1.
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for LC Shield Tape Shield/Wire Over Tape Shield. includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 1000.

R2T15L4-N0410

Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for LC Shield Tape Shield/Wire Over Tape Shield. includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 1000.
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 1000. Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch (37-50mm)

R2T15J4N0410-B3

Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 1000. Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch (37-50mm)
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0. Cable Mounting Bracket - B1 - Stainless Steel - Size .80 inch - 1.25 inch.

R2T15J1-N0240-B1

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0. Cable Mounting Bracket - B1 - Stainless Steel - Size .80 inch - 1.25 inch.
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 2 Hole Spade #2-1250kcmil, Stranded or Compressed #1 /Compact or Solid 1/0.

R2T15J1-N0230

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 2 Hole Spade #2-1250kcmil, Stranded or Compressed #1 /Compact or Solid 1/0.

Frequently Asked Questions

What cable insulation sizes does this termination support?

The Ranger2 Termination supports cable insulation diameters from 0.64 inch to 1.12 inch.

Is this termination compatible with shielded cables?

Yes, it supports tape shield, wire shield, and unshielded cable configurations.

What conductor sizes are compatible with this termination?

The termination is designed for stranded or compressed conductors ranging from #1 compact to solid 1/0.

What is the current rating of this termination?

The current rating is 1250 kcmil, suitable for high-current applications.

Is the Ranger2 Termination rated for outdoor use?

Yes, it is specifically designed as an outdoor termination for medium-voltage applications.

How to Install the R2T15M1-N0230 Ranger 2 Shrink Fit Silicone Rubber Termination on Tape Shielded Cables

This guide provides step-by-step instructions for the safe and proper installation of the R2T15M1-N0230 Ranger 2 Shrink Fit Silicone Rubber Termination on tape shielded cables, including cable preparation, ground braid installation, lug connection, and termination placement.

Estimated time: 1h

Tools needed:

Crimping tool, Cable preparation tools, Approved solvent, Aluminum oxide abrasive (120 grit or finer, if needed)

Supplies needed:

R2T15M1-N0230 Silicone Rubber Termination kit, Silicone lubricant, Gray silicone rubber electrical tape, Constant force spring, Preformed ground braid, Sealing mastic, Copper foil tape, Gloves, Terminal lug or connector (compatible with cable), Vinyl tape, Oxide inhibitor (for aluminum lugs)

  1. Prepare the Cable

    DANGER: De-energize all apparatus before starting. Verify the cable size fits the termination range. Train the cable into position and cut to the required length. Prepare the cable according to the provided dimensions, allowing for terminal lug depth and aluminum lug growth. Secure the tape shield edge with a single wrap of copper foil tape to prevent unrolling.

  2. Install the Ground Braid

    Wrap one band of mastic (50% stretch) around the cable jacket 1/4 inch (6mm) from the end, cutting flush. Position the preformed ground braid with the short tail over the tape shield and the solder block centered over the mastic. Secure the braid to the jacket with vinyl tape and press the solder block into the mastic. Apply a second mastic band (50% stretch) over the solder block and previous mastic, maintaining the 1/4 inch dimension, and cut flush. Wrap two half-lapped layers of vinyl tape around the mastic seal. Wrap the ground braid around the cable tape shield once, trim excess, and secure with the constant force spring, wrapping in the same direction. Cinch the spring and secure it with two wraps of vinyl tape.

  3. Install the Lug or Connector

    Check that the termination assembly fits over the selected lug. If not, clean the insulation and slide the termination onto the cable before installing the lug (do not remove the core yet). Position the connector or lug and crimp it according to the manufacturer's directions, avoiding crimping the last 3/8 to 1/2 inch. Remove any excess oxide inhibitor and all sharp crimp flashings or edges after crimping.

  4. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation with an approved solvent, ensuring the solvent does not touch the semi-conductive insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (120 grit or finer) on the insulation, not the semi-conductive shield, and be careful not to reduce the cable insulation diameter below the kit's allowed range.

  5. Install the Termination Body

    Create a track-resistant moisture seal by wrapping gray silicone rubber electrical tape around the base of the terminal lug. Apply a liberal coating of silicone grease to the edge of the semi-conductive insulation shield to fill the step. For lower terminations with a fold-down skirt, pull the loose end of the removable core through the top until it is flush with the bottom. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully remove the core by unwinding counter-clockwise, ensuring the termination body (not the core) is butted against the leading edge of the mastic seal. Do not push or pull the assembly during core removal.

  6. Complete Moisture Seal and Ground Connection

    Apply a thin film of silicone lubricant to the skirt and mastic seal area (do not lubricate skirt tabs). Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining gray silicone rubber electrical tape, overlapping the termination insulator by approximately 1 inch and extending over a non-crimped region of the lug/connector barrel with a half-lap configuration. Connect the ground braid to the system ground. Finally, confirm that the High-K step does not exceed 1.5 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.