ABB - Installation Products K655LR-N-AC04 - 15/25kV, 600 Amp, Elbow Connector without Test Point - with Shear Bolt Connector. Includes Elbow Housing, Insulated Plug with Cap, Stud, Shearbolt Lug, Cable Adapter and Lubricant. Cable Insulation Diameter N - 1.550 to 1.780 inch. Tin-Plated Aluminum ShearBolt Lug, Conductor Size AC04 - 750 to 1250 kcmil Stranded/Compressed/Solid/Compact.

ABB Installation Products K655LR-N-AC04 15/25kV, 600 Amp, Elbow Connector without Test Point - with Shear Bolt Connector.…

UPC: 075114354554


Documents & Media
BrochureInstallation InstructionsManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K655LR-N-AC04 is a 15/25 kV, 600 Amp elbow connector engineered for reliable underground distribution applications. This model features a shear bolt connector for secure termination and omits a test point for simplified installation where not required. The connector includes a durable poly elbow housing, an insulated plug with cap, a stud, a tin-plated aluminum shear bolt lug, a cable adapter, and lubricant for complete assembly. Designed for medium-voltage power systems, the K655LR-N-AC04 accommodates cable insulation diameters ranging from 1.550 to 1.780 inches (N). The tin-plated aluminum shear bolt lug supports conductor sizes AC04, handling 750 to 1250 kcmil stranded, compressed, solid, or compact conductors. This configuration ensures a robust electrical connection for medium-voltage power distribution infrastructure. The K655LR series from ABB Installation Products provides essential components for safe and efficient power distribution, meeting ANSI/IEEE Standard 386 requirements. The connector is fully shielded and submersible, designed for dead-front cable connections to high-voltage apparatus. It can be easily connected or disconnected using standard hand tools in a de-energized state, with optional accessories available for visible external separation, bypass, isolation, dead-ending, grounding, and testing. Applications include underground distribution systems, submersible cable connections, and high-voltage apparatus interfaces. The K655LR-N-AC04 is suitable for use with metallic tape shield or drain wire cables, with an ECS cable seal grounding device recommended for optimal performance. Manufacturer: ABB - Installation Products. SKU: K655LR-N-AC04.
  • 15/25 kV voltage class, 600 Amp continuous rating
  • Shear bolt connector for secure termination; no test point for simplified installation
  • Accommodates cable insulation diameters 1.550 to 1.780 inches (N)
  • Tin-plated aluminum shear bolt lug supports 750 to 1250 kcmil stranded/compressed/solid/compact conductors
  • Includes elbow housing, insulated plug with cap, stud, cable adapter, and lubricant

Specifications

Amperage Rating
600 A
Application
Designed to provide Fully Shielded, Dead-Front Submersible Cable Connections to High-Voltage Apparatus
Color
Black
Conductor Range
750 to 1250 kcmil
Connection
Shear Bolt
Connection Type
Shear Bolt
Current Rating
600 A
Environmental Conditions
Fully Submersible
Insulation
True
Length
13 in
Length
330.2 mm
Material
Tin-Plated Aluminum, Poly
Material
Housing - EPDM-Rubber
Series
K655LR
Size
Cable Insulation Diameter N - 1.550 to 1.780 inch, Conductor Size AC04 - 750 to 1250 kcmil
Special Features
Fully shielded, fully submersible molded rubber housing. 100 Percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps, surge arrestors, and fault current indicators
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector
Voltage Rating
15 to 25 kV
Voltage Rating
15/25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV, 600 Amp, Elbow Tap Plug, Test and Ground Connector Kit with Test Point. Includes Insulated Cap, Test and Ground Reducing Tap Plug, 600 Series Elbow Housing, Cable Adapter and Tin-Plated Aluminum ShearBolt Lug. Cable Insulation Diameter N - 1.515 to 1.780 inch. Conductor Size AC04 - 750 to 1250 kcmil Stranded/Compressed/Solid/Compact.

656ETP-N-AC04-DRG

15kV, 600 Amp, Elbow Tap Plug, Test and Ground Connector Kit with Test Point. Includes Insulated Cap, Test and Ground Reducing Tap Plug, 600 Series Elbow Housing, Cable Adapter and Tin-Plated Aluminum ShearBolt Lug. Cable Insulation Diameter N - 1.515 to 1.780 inch. Conductor Size AC04 - 750 to 1250 kcmil Stranded/Compressed/Solid/Compact.
15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95.

K656CY-H0260

15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95.
600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95.

K655YSR-H0260

600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95.
15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

K151SR-C2270

15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
15/25kV, 600 Amp, Deadbreak Elbow Connector with Test Point - with Shear Bolt Connector. Includes Elbow Housing, Insulated Plug with Cap, Stud, Shearbolt Lug, Cable Adapter and Lubricant. Cable Insulation Diameter K - 1.090 to 1.310 inch. Tin-Plated Aluminum ShearBolt Lug, Conductor Size AC03 - 500 to 750 kcmil Stranded/Compressed/Solid/Compact.

K656LR-K-AC03

15/25kV, 600 Amp, Deadbreak Elbow Connector with Test Point - with Shear Bolt Connector. Includes Elbow Housing, Insulated Plug with Cap, Stud, Shearbolt Lug, Cable Adapter and Lubricant. Cable Insulation Diameter K - 1.090 to 1.310 inch. Tin-Plated Aluminum ShearBolt Lug, Conductor Size AC03 - 500 to 750 kcmil Stranded/Compressed/Solid/Compact.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle with Test Point, Bails are required but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

K152SR-B0220

200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle with Test Point, Bails are required but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
15/25kV, 600 Amp, Deadbreak Elbow Connector without Test Point - with Shear Bolt Connector. Includes Elbow Housing, Insulated Plug with Cap, Stud, Shearbolt Lug, Cable Adapter and Lubricant. Cable Insulation Diameter M - 1.370 to 1.630 inch. Tin-Plated Aluminum ShearBolt Lug, Conductor Size AC03 - 500 to 750 kcmil Stranded/Compressed/Solid/Compact.

K655LR-M-AC03

15/25kV, 600 Amp, Deadbreak Elbow Connector without Test Point - with Shear Bolt Connector. Includes Elbow Housing, Insulated Plug with Cap, Stud, Shearbolt Lug, Cable Adapter and Lubricant. Cable Insulation Diameter M - 1.370 to 1.630 inch. Tin-Plated Aluminum ShearBolt Lug, Conductor Size AC03 - 500 to 750 kcmil Stranded/Compressed/Solid/Compact.
15/25kV, 600 Amp, Elbow Connector with Test Point - with Shear Bolt Connector. Includes Elbow Housing, Insulated Plug with Cap, Stud, Shearbolt Lug, Cable Adapter and Lubricant. Cable Insulation Diameter N - 1.550 to 1.780 inch. Tin-Plated Aluminum ShearBolt Lug, Conductor Size AC04 - 750 to 1250 kcmil Stranded/Compressed/Solid/Compact.

K656LR-N-AC04

15/25kV, 600 Amp, Elbow Connector with Test Point - with Shear Bolt Connector. Includes Elbow Housing, Insulated Plug with Cap, Stud, Shearbolt Lug, Cable Adapter and Lubricant. Cable Insulation Diameter N - 1.550 to 1.780 inch. Tin-Plated Aluminum ShearBolt Lug, Conductor Size AC04 - 750 to 1250 kcmil Stranded/Compressed/Solid/Compact.

Frequently Asked Questions

What wire sizes are compatible with these connectors?

The connectors accommodate multiple wire sizes from #2 AWG to 1500 kcmil. Note that 1500 kcmil is only for 35 kV applications.

What current ratings are these shear bolt connectors applicable for?

These shear bolt connectors are applicable for 600 amp and 900 amp current ratings.

Are these connectors compatible with aluminum and copper conductors?

Yes, the shear bolt connection system is compatible with both aluminum and copper conductors.

What voltage range do these connectors support?

The shear bolt connectors are applicable for 600/900 amp elbow connectors, vault stretchers and straight receptacles from 15 kV up to 35 kV.

What industry standard do these connectors meet?

The Elastimold advanced shear bolt connection system meets IEEE 386 latest revision.

What is a critical safety step before installation?

The circuit must be de-energized before beginning the installation process to ensure safety.

What tools are needed for installation?

Only a standard wrench is needed for installation; no dies or pneumatic tools are required.

What voltage range do these connectors support?

The shear bolt connectors are applicable for 600/900 amp elbow connectors, vault stretchers and straight receptacles from 15 kV up to 35 kV.

What wire sizes are compatible with these connectors?

The connectors accommodate multiple wire sizes from #2 AWG to 1500 kcmil. Note that 1500 kcmil is only for 35 kV applications.

What current ratings are these shear bolt connectors applicable for?

These shear bolt connectors are applicable for 600 amp and 900 amp current ratings.

How to Install the K655LR-N-AC04 Shear Bolt Connector

Instructions for installing the K655LR-N-AC04 shear bolt connector on copper or aluminum conductors.

Estimated time: 30m

Tools needed:

Hexagon socket (AF 3/4” or SW19), Wire brush, Pliers (for manual rework, if needed)

Supplies needed:

K655LR-N-AC04 Shear Bolt Connector, Cable accessory (for preparation), Insulated cap or connector (if submerging/energizing)

  1. Inspect and Prepare Components

    Verify that the package contents are complete and undamaged. Check all components for proper fit with the cable and mating products. Read all installation instructions before starting. Have all required tools at hand and maintain cleanliness throughout the procedure.

  2. Insert Center Ring

    Insert the appropriate center ring into the barrel of the K655LR-N-AC04 connector. Refer to the table in the documentation for the correct center ring based on conductor type and size (750 kcmil).

  3. Prepare Cable

    Prepare the cable as specified in the instructions accompanying the applicable cable accessory. Clean the conductor surface using a wire brush, especially for aluminum conductors, immediately before inserting it into the barrel.

  4. Initial Bolt Tightening

    Insert the conductor into the barrel. Loosely install bolts #1, #2, and #3. Apply slow, steady turns to bolt #1 until it makes contact with the conductor. Repeat this process for bolts #2 and #3.

  5. Shear Bolt Heads

    Using the specified hexagon socket (AF 3/4” or SW19), begin with bolt #1 and apply torque alternately to each bolt. Continue applying torque until the head of each bolt shears off flush with the connector barrel. It is recommended to hold the connector barrel securely during this process. Do not use impact guns.

  6. Verify Shearing and Rework if Necessary

    Inspect the connector to ensure all bolt heads have sheared off flush with the connector barrel. If any bolt heads do not shear off flush, manual rework is required. Contact Elastimold® technical services for guidance.

  7. Finalize Installation

    If the product was supplied with protective shipping covers, remove them and replace them with the appropriate HV insulated caps or connectors before submerging or energizing the circuit.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.