ABB - Installation Products K151SR-C2270 - 15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

ABB Installation Products K151SR-C2270 15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included…

UPC: 075114343510


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K151SR-C2270 is a 15/25kV 200 Amp deadbreak straight receptacle designed for medium-voltage cable terminations. This product features a copper compression lug compatible with compressed stranded conductors ranging from 4/0 AWG to 250 mm² (126.67 mm² equivalent) and accommodates cable insulation diameters between 0.805 inch and 1.060 inch. The deadbreak design ensures safe, load-break operations without visible arcs, making it suitable for underground distribution systems, switchgear, and pad-mounted transformers. This receptacle is rated for 200 Amperes continuous current and is constructed for reliable performance in utility and industrial applications. The straight configuration simplifies installation in tight spaces while maintaining dielectric integrity. Note that bail assemblies are required for proper operation but must be ordered separately to match system requirements. Common applications include: - Underground residential and commercial distribution - Industrial power systems - Utility substations - Wind and solar farm interconnections The ABB K151SR-C2270 is manufactured to ABB’s Installation Products standards, ensuring compatibility with industry-standard medium-voltage accessories. For optimal performance, verify conductor size and insulation diameter against system specifications before installation.
  • Rated 15/25kV, 200 Amperes continuous current
  • Deadbreak design for safe load-break operations
  • Copper compression lug for 4/0 AWG to 250 mm² conductors
  • Accepts cable insulation diameters 0.805" to 1.060"
  • Straight configuration for compact installations

Specifications

Amperage Rating
200 A
Application
Designed to connect a cable to another cable or apparatus
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Connection Type
Deadbreak Straight Receptacle
Current Rating
200 A
Environmental Conditions
Fully Shielded, Fully Submersible
Insulation
True
Length
9.54 in
Length
242.316 mm
Material
Housing - EPDM-Rubber
Material
Copper
Series
K151SR
Size
0.805 inch to 1.060 inch
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for ground wire connection. Wide cable range with minimum number of sizes. No Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Receptacle
Voltage Rating
15 to 25 kV
Voltage Rating
15/25 kV
Width
2.74 in
Width
69.596 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.

755LR-K2270

600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.
Copper-coated conductor 1,90m 63A x2

173G0412

Copper-coated conductor 1,90m 63A x2
Solenoid Valve Connectors, Accessory, Thumb screw, Cabled Form A, B, ISB, and FW ISC

V-25TB

Solenoid Valve Connectors, Accessory, Thumb screw, Cabled Form A, B, ISB, and FW ISC
15/25kV, 600 Amp, Deadbreak Elbow Connector with Test Point - with Shear Bolt Connector. Includes Elbow Housing, Insulated Plug with Cap, Stud, Shearbolt Lug, Cable Adapter and Lubricant. Cable Insulation Diameter K - 1.090 to 1.310 inch. Tin-Plated Aluminum ShearBolt Lug, Conductor Size AC03 - 500 to 750 kcmil Stranded/Compressed/Solid/Compact.

K656LR-K-AC03

15/25kV, 600 Amp, Deadbreak Elbow Connector with Test Point - with Shear Bolt Connector. Includes Elbow Housing, Insulated Plug with Cap, Stud, Shearbolt Lug, Cable Adapter and Lubricant. Cable Insulation Diameter K - 1.090 to 1.310 inch. Tin-Plated Aluminum ShearBolt Lug, Conductor Size AC03 - 500 to 750 kcmil Stranded/Compressed/Solid/Compact.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle with Test Point, Bails are required but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

K152SR-B0220

200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle with Test Point, Bails are required but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
15/25kV, 600 Amp, Deadbreak Elbow Connector without Test Point - with Shear Bolt Connector. Includes Elbow Housing, Insulated Plug with Cap, Stud, Shearbolt Lug, Cable Adapter and Lubricant. Cable Insulation Diameter M - 1.370 to 1.630 inch. Tin-Plated Aluminum ShearBolt Lug, Conductor Size AC03 - 500 to 750 kcmil Stranded/Compressed/Solid/Compact.

K655LR-M-AC03

15/25kV, 600 Amp, Deadbreak Elbow Connector without Test Point - with Shear Bolt Connector. Includes Elbow Housing, Insulated Plug with Cap, Stud, Shearbolt Lug, Cable Adapter and Lubricant. Cable Insulation Diameter M - 1.370 to 1.630 inch. Tin-Plated Aluminum ShearBolt Lug, Conductor Size AC03 - 500 to 750 kcmil Stranded/Compressed/Solid/Compact.
15/25kV, 600 Amp, Elbow Connector with Test Point - with Shear Bolt Connector. Includes Elbow Housing, Insulated Plug with Cap, Stud, Shearbolt Lug, Cable Adapter and Lubricant. Cable Insulation Diameter N - 1.550 to 1.780 inch. Tin-Plated Aluminum ShearBolt Lug, Conductor Size AC04 - 750 to 1250 kcmil Stranded/Compressed/Solid/Compact.

K656LR-N-AC04

15/25kV, 600 Amp, Elbow Connector with Test Point - with Shear Bolt Connector. Includes Elbow Housing, Insulated Plug with Cap, Stud, Shearbolt Lug, Cable Adapter and Lubricant. Cable Insulation Diameter N - 1.550 to 1.780 inch. Tin-Plated Aluminum ShearBolt Lug, Conductor Size AC04 - 750 to 1250 kcmil Stranded/Compressed/Solid/Compact.
600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compacted Solid #2.

K655YSR-F0210

600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compacted Solid #2.

Frequently Asked Questions

Does the K151SR have a provision for a ground wire?

Yes, the K151SR includes a provision for a ground wire connection.

What is the K151SR Straight Receptacle used for?

The K151SR Straight Receptacle is a fully shielded, fully submersible connector designed to connect a cable to another cable or apparatus. It requires an appropriate Elastimold® mating product.

What voltage systems is the K151SR suitable for?

The K151SR is suitable for use on both 15kV and 25kV systems.

What are the operating voltage limits for 15kV systems?

For 15kV systems, the maximum phase-to-ground operating voltage is 8.3kV and the maximum phase-to-phase is 14.4kV.

What are the operating voltage limits for 25kV systems?

For 25kV systems, the maximum phase-to-ground operating voltage is 15.2kV and the maximum phase-to-phase is 26.3kV.

What is the continuous current rating of the K151SR?

The K151SR has a continuous current rating of 200 Amp for both 15kV and 25kV voltage classes.

What conductor sizes does the K151SR accommodate?

The K151SR accommodates conductor sizes from No. 4 solid through 4/0 stranded.

What cable insulation diameters are compatible with K151SR?

The K151SR accommodates cable insulation diameters from 0.575 inches through 1.220 inches.

When can the disconnectible feature be used?

The disconnectible feature of the K151SR can be used only when the circuit is de-energized.

What standard does the K151SR meet?

The K151SR meets ANSI/IEEE Standard 386, Latest Revision.

How to Install the 151SR/K151SR Straight Receptacle

This guide provides step-by-step instructions for installing the 151SR/K151SR Straight Receptacle, designed to connect solid dielectric type cables to other Elastimold products or electrical apparatus. Ensure all apparatus are de-energized before beginning installation.

Estimated time: 1h

Tools needed:

Wire brush, Crimping tool, Wire strippers, Rag

Supplies needed:

151SR/K151SR Straight Receptacle, Conductor Contact (male), Nylon Venting Rod, Lubricant (supplied), Approved solvent, Copper wire (#14 AWG or equivalent), Elastimold bail

  1. Prepare for Installation and Safety Check

    Before starting, de-energize all apparatus. Inspect all parts for damage, proper rating, and compatibility. Gather all required tools and maintain cleanliness. This product should only be installed by competent personnel trained in high voltage electrical equipment safety practices. Failure to follow instructions can result in serious injury.

  2. Prepare Cable Jacket (Concentric Neutral or Tape Shield)

    For jacketed concentric neutral cable, cut and remove the cable jacket 8 inches from the end, ensuring sufficient neutral wires for grounding. For copper tape shield cable, cut and remove the cable jacket 7 1/2 inches from the end, then remove the copper tape shield 6 1/2 inches from the cable end.

  3. Remove Insulation and Conductive Shield

    Remove 7/8 inch to 1 inch (or 1 3/4 inches to 1 7/8 inches for #1 stranded/compr. and #1/0 comp./solid aluminum cable) of cable insulation and conductive shield. Cut squarely, do not pencil. Wire brush bare aluminum conductors and immediately insert them into the crimp barrel which contains inhibitor.

  4. Crimp the Conductor Contact

    Crimp the socket terminal onto the bared conductor, ensuring the conductor remains fully seated. Refer to the crimp chart provided with the contact. Start crimps at the imprinted crimp line and rotate each successive crimp or indent 90 degrees. If using aluminum cable, carefully wipe excess inhibitor from the contact and cable insulation.

  5. Prepare and Clean Insulation

    Remove the semi-conductive shield 7 9/16 inches to 7 5/8 inches back from the end of the pin with a straight, smooth, 'squared' cut, avoiding nicks to the insulation. Pencil insulation 1/8 inch. Clean the outer jacket and insulation thoroughly with an approved solvent, wiping from the end of the cable toward the outer jacket to remove all traces of semi-conducting residue.

  6. Lubricate the Cable and Receptacle

    Remove the protective cap from the straight receptacle, keeping the cable insulation and receptacle clean. Apply the supplied lubricant sparingly to the cable as shown and to the inside of the housing. Do not substitute other lubricants, as they may be harmful to the product or its mating product.

  7. Insert Cable into Receptacle Housing

    Push the cable into the housing until the base of the pin chamfer is flush with the inside face of the receptacle. If the receptacle is not to be immediately connected, replace the protective cover (note: shipping cover offers dirt protection only, it is not an insulating device).

  8. Connect to a Mating Plug

    To connect to a mating plug, first lubricate the nose of the plug with silicone grease. Place the nylon rod into the receptacle face until it bottoms (approximately 1 3/4 inches), ensuring the rod is not cut. Insert the plug assembly into the receptacle as far as possible, then pull out the nylon rod. Secure the electrical connection with an Elastimold bail.

  9. Ground the Cable

    If an ELASTIMOLD grounding device is not being used, connect a length of #14 AWG (or equivalent) copper wire (customer supplied) through the grounding tab and twist tightly. Connect the grounding assembly of the connector to the system ground by merging with the cable shield of each cable. Seal the grounding wires and connections to prevent corrosion.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.