Overview
- 15/25kV Voltage Rating
- 600 Series Direct Test Elbow Design
- Accommodates 1.370" - 1.630" Cable Insulation Diameter
- Supports 700/750 kcmil Stranded or 900 kcmil Solid/Compacted Conductors
- Cold Shrinkable Jacket Seal for Environmental Protection
Specifications
Amperage Rating | 600 A |
Application | 15/25kV, 600 Amps |
Color | Black |
Conductor Range | 700/750 kcmil STR , 900 kcmil SOL |
Connection | Compression |
Environmental Conditions | All Weather Conditions, Fully Submersible |
Insulation | True |
Length | 13 in |
Length | 330.2 mm |
Material | Housing - EPDM-Rubber |
Special Features | Fully shielded, fully submersible molded rubber housing. 100 Percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps, surge arrestors, and fault current indicators. Direct conductor test point equipped elbow. Cold Shrinkable Jacket Seal |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Direct Test Elbow Connector |
Voltage Rating | 15 to 25 kV |
Width | 10.36 in |
Width | 263.144 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

168FLR1-B5220
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit
162A4-B5220
15kV, 200 Amp, Loadbreak Elbow with Bushing Insert Kit with Test Point, Cable Insulation Diameter B - 0.635 to 0.905 inch (16.13-22.99mm). Bi-Metal Compression Lug, Conductor Size 220 - #2 Stranded/Compressed or #1 Solid/Compact.
756LR-K2270-SG3
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Copper Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size Compressed-Stranded 4/0 AWG Compacted-Solid 250 kcmil. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
376LR-H-2240-S
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point and Sealing Kit, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS Jacket Seal Included.
2701DLA
25kV, 200 Amp, DeadBreak to LoadBreak Bushing Adapter, Blue. Includes hex-broach for Torque installation, Peroxide-cured insulation and jacket, Provision for ground wire connection, All copper current path. Blue PBT interface shield reduces sticking and provides seating indicator.
252LR-B2035-S
12/20 24kV, 250 Amp, Deadbreak, Elbow Connector with Test Point, with Sealing Kit, Cable Insulation Diameter - 16.13 mm - 22.90 mm, Copper Compression Lug, Conductor Size 35mm. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide. IEC Standard.
262LR-E2250-S
25kV, 200 Amps, Loadbreak Elbow, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Copper Conductor, Conductor Size 2/0 Stranded/Compressed, 3/0 Solid/Compact. With Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installation Instruction Sheet and Crimp Chart. S - Cold Shrinkable Jacket Seal.
162A4-C5270
15kV, 200 Amp, Loadbreak Elbow with Bushing Insert Kit with Test Point, Cable Insulation Diameter C - 0.805 to 1.060 inch (20.45-26.92mm). Bi-Metal Compression Lug, Conductor Size 270 -4/0 Stranded/Compressed or 250 kcmil Solid/Compact.Frequently Asked Questions
What cable insulation diameters does the K655DLR support?
The K655DLR supports cable insulation diameters ranging from 0.640 in to 1.935 in (16.256 mm to 49.149 mm).
What is the continuous current rating?
The continuous current rating for both 15kV and 28kV voltage classes is 600 Amps.
What are the 15kV operating voltage limits?
For 15kV, the maximum phase-to-ground operating voltage is 8.3kV, and the maximum phase-to-phase voltage is 14.4kV.
What is the K655DLR Direct Test Elbow?
It is a fully rated 15/25kV, 600 Amp Class deadbreak elbow connector that incorporates the Elastimold Direct Test System (EDTS) for isolation, testing, and grounding.
What is the momentary current rating?
The momentary current rating for both 15kV and 28kV voltage classes is 25kA Sym for 10 cycles.
What are the 28kV operating voltage limits?
For 28kV, the maximum phase-to-ground operating voltage is 16.2kV, and the maximum phase-to-phase voltage is 28kV.
Can the K655DLR be connected while energized?
No, the K655DLR can only be connected or disconnected using standard hand tools and equipment when it is in a de-energized state.
What items are included in the K655DLR kit?
Each kit contains an elbow connector housing, a copper compression lug, a stud, an insulated plug with cap, lubricant, a cable adapter, and installation instructions.
What cable insulation diameters does the K655DLR support?
The K655DLR supports cable insulation diameters ranging from 0.640 in to 1.935 in (16.256 mm to 49.149 mm).
What is the K655DLR Direct Test Elbow?
It is a fully rated 15/25kV, 600 Amp Class deadbreak elbow connector that incorporates the Elastimold Direct Test System (EDTS) for isolation, testing, and grounding.
How to Install the K655DLR-M0380-S Direct Test Elbow Connector
Instructions for installing and connecting the K655DLR-M0380-S Direct Test Elbow Connector to a high voltage apparatus.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Hotstick tool, Crimping tool
Supplies needed:
Mounting screws, Terminal connectors, Lubricant, Vinyl plastic tape, Tape retainer, Tape marker, Grounding wire, Suitable connector for ground
- Prepare the Cable
Position the cable in its final location with enough slack. For concentric neutral cable, unwind the wires. Cut the cable 1-3/4” (45mm) from the center line of the mating product. Clean the outer surface of the cable for 24” (610mm). Follow specific instructions for removing outer jacket, shield wires, flat metallic tape shield, fabric tape shield, longitudinally corrugated shield, UNISHIELD cable, lead sheath cable, or semi-con shield as applicable to your cable type. Ensure all dimensions are followed precisely. For UNISHIELD or lead sheath cable, a 10TL cable shield adapter is required; refer to its specific instructions.
- Install the Cable Adapter
Bevel the end of the cable insulation at a 45° angle, approximately 1/4” (6mm) back. Thoroughly clean and lubricate the cable insulation, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.
- Prepare the Conductor
Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Ensure the conductor is not nicked. The exposed conductor length should be between 4-3/8” (111mm) and 4-11/16” (119mm). If not, redo the assembly.
- Install the Compression Lug
For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it into the compression lug. Measure the 'Check Dimension' before crimping; it must be less than 6-1/2” (165mm). Crimp the lug according to its instructions. Wipe excess inhibitor. The distance from the end of the compression lug to the cable adapter after crimping should be between 6-1/2” to 7-1/4” (165mm – 184mm).
- Install the Elbow
Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.
- Connect to Mating Product
WARNING: DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. Remove protective caps from the elbow and the mating part. If the mating part is not equipped with a stud, hand-tighten the supplied threaded stud into it. Clean and lubricate both the elbow and the mating part. Push the elbow onto the mating part, aligning the compression lug hole with the stud. Clean and lubricate the mating part for the opposite end of the elbow, insert it, engage threads, and hand-tighten. Torque the mating part according to its specific instructions.
- Install Insulating Plug (If Applicable)
If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap. Place the cap on the elbow and push down firmly until it snaps into place. Follow voltage test directions.
- Ground the Cable Shield
Insert one end of a wire (ampacity at least No. 14 AWG copper) through the grounding eye and twist to form a small loop. Connect this wire to ground using a suitable connector. The cable shield must be grounded according to the instructions of the grounding device used, or an alternate method if no device is used. It is recommended to waterproof the cable jacket at this point to prevent moisture ingress.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.