ABB Installation Products 162A4-B5220 15kV, 200 Amp, Loadbreak Elbow with Bushing Insert Kit with Test Point, Cable Insulation…
UPC: 075114353960
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15kV, 200 Amp rated loadbreak elbow for medium-voltage applications
- Integrated test point for safe circuit verification without disconnection
- Supports cable insulation diameter B: 0.635 to 0.905 inches (16.13-22.99mm)
- Bi-Metal compression lug compatible with 220 kcmil stranded/compressed or #1 AWG solid/compact conductors
- Includes probe (162LRF), probe wrench (271-94), bushing insert (1601A4), and lubricant tube (82-08)
Specifications
Amperage Rating | 200 A |
Application | 15kV 200 Amp |
Color | Black |
Conductor Range | #2 STR/COMPR AWG , #1 SOL/COMP AWG |
Connection | Compression |
Connection Type | Compression Lug |
Current Rating | 200 A |
Environmental Conditions | Fully Submersible |
Insulation | True |
Length | 2.9 in |
Length | 73.66 mm |
Material | Bi-Metal, Poly |
Material | Bi-Metal Compression Lug |
Material | Housing - EPDM-Rubber |
Series | 162A4 |
Size | 0.635 to 0.905 inch |
Size | Cable Insulation Diameter B - 0.635 to 0.905 inch (16.13-22.99mm) |
Special Features | Non-corrosive capacitive test point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow with Test Point and Bushing |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

655ETP-N0410-DRG
15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter and 0370 style compression lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.
756LR-K2270-SG3
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Copper Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size Compressed-Stranded 4/0 AWG Compacted-Solid 250 kcmil. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
376LR-H-2240-S
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point and Sealing Kit, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS Jacket Seal Included.
2701DLA
25kV, 200 Amp, DeadBreak to LoadBreak Bushing Adapter, Blue. Includes hex-broach for Torque installation, Peroxide-cured insulation and jacket, Provision for ground wire connection, All copper current path. Blue PBT interface shield reduces sticking and provides seating indicator.
252LR-B2035-S
12/20 24kV, 250 Amp, Deadbreak, Elbow Connector with Test Point, with Sealing Kit, Cable Insulation Diameter - 16.13 mm - 22.90 mm, Copper Compression Lug, Conductor Size 35mm. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide. IEC Standard.
262LR-E2250-S
25kV, 200 Amps, Loadbreak Elbow, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Copper Conductor, Conductor Size 2/0 Stranded/Compressed, 3/0 Solid/Compact. With Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installation Instruction Sheet and Crimp Chart. S - Cold Shrinkable Jacket Seal.
162A4-C5270
15kV, 200 Amp, Loadbreak Elbow with Bushing Insert Kit with Test Point, Cable Insulation Diameter C - 0.805 to 1.060 inch (20.45-26.92mm). Bi-Metal Compression Lug, Conductor Size 270 -4/0 Stranded/Compressed or 250 kcmil Solid/Compact.
252LR-B2050
12/20 24kV, 250 Amp, Deadbreak, Elbow Connector with Test Point, No Sealing Kit, Cable Insulation Diameter - 16.13 mm - 22.90 mm, Copper Compression Lug, Conductor Size 50mm. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide. IEC Standard.Frequently Asked Questions
What is the voltage rating of the 162A4 elbow connector?
The 162A4 elbow connector is rated for 15kV voltage class, with an 8.3kV maximum phase-to-ground operating voltage and 14.4kV maximum phase-to-phase.
What type of conductors are compatible with the compression lugs?
Copper compression lugs are for copper conductors only, while bi-metal compression lugs with universal aluminum barrels are suitable for both copper or aluminum conductors.
What sealing and grounding kit is used for copper tape shield cables?
For copper tape shield cables, the 200ECSG3 sealing and grounding kit is used, or add suffix "-SG3" to the part number for cables with nominal O.D. within 0.80-1.50 inches.
What sealing and grounding kit is used for jacketed concentric neutral cables?
For jacketed concentric neutral cables, the 200ECS sealing kit is used, or add suffix "-S" to the part number for cables with nominal O.D. within 0.80-1.50 inches.
Is a sealing and grounding kit required for the 162A4?
For safety purposes, a sealing and grounding kit with the loadbreak elbow is highly recommended.
Can the 162A4 be operated with hotstick tools?
Yes, the 162A4 includes provisions for energized operation using standard hotstick tools, allowing loadmake/loadbreak operation and a visible disconnect.
Does the 162A4 connector meet industry standards?
Yes, the 162A4 elbow connector meets ANSI/IEEE Standard 386, Latest Revision.
What cable insulation diameters are compatible with the 162A4?
The 162A4 allows connection of cables with insulation diameters from .575 inches (14.6mm) to 1.220 inches (31.0mm).
What is the continuous current rating for this connector?
The 162A4 elbow connector has a continuous and loadbreak current rating of 200 Amps.
What shield adapter is used for Unishield cables?
For Unishield cables, the 10TL-W shield adapter is used, where 'W' is determined by the cable's insulation diameter, or add suffix "-TL" to the part number.
How to Install 161LR/162LR Loadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe installation and assembly of 161LR (without test point) and 162LR (with test point) Loadbreak Elbow Connectors, designed to terminate various UD cables to 15kV class loadbreak bushings.
Estimated time: 1h 45m
Tools needed:
Wire strippers, Wire brush, Crimp tool, Probe wrench, Hotstick (for operation)
Supplies needed:
Lubricant (supplied), Compression lug (supplied), Probe (supplied), Copper wire (No. 14 AWG / 2.5mm) or equivalent, Vinyl tape (if applicable), Conductive copper tape (if applicable), Cold shrink tube (if applicable)
- Perform Initial Safety Checks and Prepare Workspace
DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products. Inspect all parts for damage, proper rating, and compatibility with mating components. Ensure the package contents are complete and undamaged. Check all components for proper fit with the cable and/or mating products. Read the entire installation instructions before starting and have all required tools at hand, maintaining cleanliness throughout the procedure.
- Train and Prepare the Cable Shield
Train the cable to ensure adequate slack for ease of operation. Based on your cable type (non-jacketed concentric neutral, jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield), follow the specific instructions in the document (Step 1 A, B, C, or D) to prepare the cable. This includes pulling extra cable, binding neutrals, removing outer jackets, unwrapping ground wires, and applying sealing kits if required. Cut the excess cable squarely at the centerline of the bushing.
- Prepare Conductor and Insulation
Remove the shield and insulation 2-1/8 inches (55mm) from the cable end, cutting squarely and taking care not to nick the conductor. Wire brush bare aluminum conductors and immediately install the compression lug, rotating it to spread the inhibitor. Position the lug so the contact threaded hole aligns with the bushing bore. Refer to the crimp chart with the lug for tool information, starting crimp at the mark and rotating 180 degrees for each successive crimp. Carefully wipe excess inhibitor. Remove the insulation shield as shown in the diagram, beveling the insulation end 1/8 inch (5mm) maximum. Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.
- Assemble the Elbow Connector
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; DO NOT SUBSTITUTE. Slide the elbow connector onto the cable with a back-and-forth twisting motion, then wipe off all excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends.
- Ground the Elbow Connector
Insert one end of a separate copper wire (No. 14 AWG / 2.5mm) or equivalent through the grounding eye on the elbow. Twist tightly, taking care not to damage the eye. If the elbow is preordered with a ground wire, proceed to the next step. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack in the wires for elbow operation. If using a cold shrink grounding kit, refer to its supplied instructions.
- Connect Elbow to Bushing Plug
CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Operate the connection using a full insulated 'hotstick' type tool; DO NOT OPERATE BY HAND. Securely fasten the hotstick to the loadbreak connector pulling eye. Insert the probe tip approximately 2 inches (50mm) into the bushing, then immediately push the elbow home with a fast, firm, straight motion to engage the internal lock.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.