ABB Installation Products 262LR-E2250-S 25kV, 200 Amps, Loadbreak Elbow, Cable Insulation Diameter 1.090-1.310 inches…
UPC: 075114428354
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 25kV rated, 200 Amp continuous current capacity
- Accommodates cable insulation diameters 1.090-1.310 inches (27.69-33.27 mm)
- Cold shrinkable jacket seal for heat-free installation
- Integrated test point for safe circuit testing
- Kit includes elbow housing, compression lug, probe, wrench, lubricant, and installation guide
Specifications
Amperage Rating | 28 kV |
Application | Designed for connecting to and operating 28kV class, 200 Amp Distribution Apparatus |
Color | Black |
Conductor Range | 2/0 ASTR/COMPR AWG , 3/0 SOL/COMPT AWG |
Connection Type | Loadbreak Elbow |
Current Rating | 200 A |
Environmental Conditions | Fully Submersible |
Insulation | True |
Material | Copper |
Material | Housing - EPDM-Rubber |
NEMA Rating | 200 A |
Size | 1.090-1.310 inches (27.69-33.27 mm) |
Size | Cable Insulation Diameter 1.090-1.310 inches, |
Special Features | Fully Shielded, Fully Submersible Molded Rubber Housing. 100 percent Peroxide-Cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector with Test Point |
Voltage Rating | 25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

168FLR1-B5220
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit
162A4-C5270
15kV, 200 Amp, Loadbreak Elbow with Bushing Insert Kit with Test Point, Cable Insulation Diameter C - 0.805 to 1.060 inch (20.45-26.92mm). Bi-Metal Compression Lug, Conductor Size 270 -4/0 Stranded/Compressed or 250 kcmil Solid/Compact.
252LR-B2050
12/20 24kV, 250 Amp, Deadbreak, Elbow Connector with Test Point, No Sealing Kit, Cable Insulation Diameter - 16.13 mm - 22.90 mm, Copper Compression Lug, Conductor Size 50mm. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide. IEC Standard.
M465LR-P2330
35kV, 630 Amp, Deadbreak Elbow, No Test Point, IEC-IEEE, No Sealing Kit. Cable Insulation Diameter 1.725 to 1.935 inch, Copper Lug, Wire Range 500 kcmil Stranded/Compressed or 600 kcmil Solid Compact or 250/300 mm2. 10.36 inch (264.1mm) x 13 inch (330.2mm) from Bottom to Center of Bushing. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Lubricant, Cable Adapter, Installation Instructions and Crimp Chart.
M465LR-N-2290
35kV, 630 Amp, Deadbreak Elbow, No Test Point, IEC-IEEE, No Sealing Kit. Cable Insulation Diameter 1.515 to 1.780 inch, Copper Lug, Wire Range 300 kcmil Stranded/Compressed or 350 kcmil Solid Compact or 150 mm2. 10.36 inch (264.1mm) x 13 inch (330.2mm) from Bottom to Center of Bushing. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Lubricant, Cable Adapter, Installation Instructions and Crimp Chart.
M465LR-L-2230
35kV, 630 Amp, Deadbreak Elbow, No Test Point, IEC-IEEE, No Sealing Kit. Cable Insulation Diameter 1.180 to 1.465 inch, Copper Lug, Wire Range 1 Stranded/Compressed or 1/0 Solid Compact or 50 mm2. 10.36 inch (264.1mm) x 13 inch (330.2mm) from Bottom to Center of Bushing. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Lubricant, Cable Adapter, Installation Instructions and Crimp Chart.
M465LR-G2250
35kV, 630 Amp, Deadbreak Elbow, with Test Point, IEC-IEEE, No Sealing Kit. Cable Insulation Diameter 0.760 to 0.95 inch, Copper Lug, Wire Range 2/0 Stranded/Compressed or 3/0 Solid Compact or 70 mm2. 10.36 inch (264.1mm) x 13 inch (330.2mm) from Bottom to Center of Bushing. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Lubricant, Cable Adapter, Installation Instructions and Crimp Chart.
K676ELR-L5330-S
25 kV, 900 Amp, Extended Elbow, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. Cold-Shrinkable Jacket Seal Included.Frequently Asked Questions
Is the elbow accepted by Rural Utilities Service?
Yes, the enhanced Elastimold 200 amp loadbreak elbow has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA). This authorizes its use in rural infrastructure construction.
Does the 15 kV elbow have improved insulation?
Yes, the enhanced 15 kV Elastimold 200 amp loadbreak elbow features improved insulation.
What ensures proper switching for the elbow?
The enhanced Elastimold 200 amp loadbreak elbow incorporates rigid probe support to ensure proper switching.
Does the elbow have a no-stick interface?
Yes, the enhanced Elastimold 200 amp loadbreak elbow has a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.
What type of pulling eye does the elbow have?
The enhanced Elastimold 200 amp loadbreak elbow features a robust stainless-steel pulling eye.
Does the elbow offer multiple grounding options?
Yes, the enhanced Elastimold 200 amp loadbreak elbow includes dual grounding eye positions.
Is an integral jacket seal available for the elbow?
Yes, the enhanced Elastimold 200 amp loadbreak elbow offers an optional integral jacket seal.
Does the elbow offer lifetime ease of operation?
Yes, the enhanced Elastimold 200 amp loadbreak elbow provides lifetime ease of operation and is non-stick when used with Elastimold bushings.
Does the elbow have an improved seal system?
Yes, the enhanced Elastimold 200 amp loadbreak elbow features an improved seal system for both traditional and jacket seal options.
Is the loadbreak elbow IEEE 386 compliant?
Yes, the enhanced Elastimold 200 amp loadbreak elbow is compliant with IEEE 386 standards.
How to Install 262LR Loadbreak Elbow Connectors
A comprehensive guide for the safe installation and initial connection of 262LR Loadbreak Elbow Connectors, including cable preparation, assembly, and grounding procedures.
Estimated time: 1h 30m
Tools needed:
Probe Wrench, Hotstick tool, Wire brush, Crimp tool (specific to compression lug), Wire strippers, Vinyl tape (optional, depending on cable type)
Supplies needed:
262LR Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied with kit), Copper ground wire (No. 14 AWG / 2.5mm or equivalent), Grounding connector (for neutral wires), Cold shrink tube (if using sealing kit), Conductive copper tape (if using 200ECS-G2 kit)
- Safety First: De-energize and Inspect
DANGER: Before starting, ensure all apparatus is de-energized. Inspect all parts for damage, proper rating, and compatibility with mating components. Read all instructions thoroughly and have all required tools and supplies ready. Maintain cleanliness throughout the procedure. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment.
- Prepare the Cable
Train the cable to ensure adequate slack for operation. Refer to the specific cable type section (Non-Jacketed Concentric Neutral, Jacketed Concentric Neutral, Jacketed Cable with Drain Wires, or Jacketed Copper Tape Shield) in the documentation for precise jacket and shield removal dimensions. Cut the cable squarely at the bushing centerline. Manage neutral or ground wires as specified for your cable type, ensuring extra length for connection to tank ground or using a jumper/braid. If using a sealing kit, slide the cold shrink tube onto the cable now.
- Prepare Cable End and Install Compression Lug
Remove 2-1/8 inches (55mm) of shield and insulation from the cable end, cutting squarely without nicking the conductor. Wire brush bare aluminum conductors immediately. Install the compression lug, rotating it to spread inhibitor. Position the lug so its contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart provided, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe off any excess inhibitor from the lug and cable.
- Remove Insulation Shield and Clean
Remove the insulation shield 6-7/8 inches (175mm) from the cable end, ensuring a straight, smooth, and squared cut. Bevel the insulation end a maximum of 1/8 inch (5mm). Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.
- Assemble the Elbow Connector
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant. DO NOT SUBSTITUTE other lubricants, as they may be harmful to the product. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends, indicating proper torque.
- Ground the Elbow and Neutral Wires
Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow and twist it tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack for elbow operation. If using a cold shrink grounding kit, refer to its specific instructions for completion.
- Connect Elbow to Bushing (De-energized)
CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Remove the insulated cap from the bushing using a hotstick tool. Securely fasten the hotstick to the loadbreak connector pulling eye. With positive control, insert the probe tip approximately 2 inches (50mm) into the bushing. Immediately push the elbow home with a fast, firm, straight motion, applying sufficient force to engage the internal lock on the elbow connector and bushing interface. DO NOT OPERATE BY HAND.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.