ABB Installation Products K151SR-C0220 200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not…
UPC: 783786504893
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 200 A current rating for medium-voltage applications
- 15/25 kV voltage rating with deadbreak design
- Aluminum compression lug for #2 AWG compressed stranded or #1 AWG solid conductors
- Supports cable insulation diameters from 0.805" to 1.060"
- Straight receptacle configuration for deadfront switchgear compatibility
Specifications
Amperage Rating | 200 A |
Application | Designed to connect a cable to another cable or apparatus |
Color | Black |
Conductor Range | #2 STR/COMPR AWG , #1 SOL/COMPT AWG |
Environmental Conditions | Fully Shielded, Fully Submersible |
Insulation | True |
Length | 9.54 in |
Length | 242.316 mm |
Material | Housing - EPDM-Rubber |
Special Features | Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for ground wire connection. Wide cable range with minimum number of sizes. No Test Point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Straight Receptacle |
Voltage Rating | 15 to 25 kV |
Width | 2.74 in |
Width | 69.596 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

168FLR1-B5220
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit
K151SP-B2200
200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Includes a copper compression lug. Conductor Size AWG Compressed Stranded #4/Solid #3/mmSquared 21.14.
K151SR-B0210
Straight Receptacle, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #3 or Solid #2 or mmSquared 26.67.
K151SP-A0200
15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #4/Solid #3/mmSquared 21.14.
274ELR-K-5270
25kV 200 Amp, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
K151SP-B2230
200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Includes a copper compression lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41
273RLR-G-5230
200 Amp, 25kV, Loadbreak Replacement Elbow Connector without Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
K151SP-D0270
200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.890 inch to 1.220 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.Frequently Asked Questions
What industry standard does the K151SR meet?
The K151SR meets ANSI/IEEE Standard 386, Latest Revision.
Does the K151SR have a ground wire connection?
Yes, the K151SR Deadbreak Straight Receptacle includes a provision for a ground wire connection.
When can the K151SR's disconnect feature be used?
The disconnectible feature of the K151SR can only be used when the circuit is de-energized.
What is the continuous current rating for the K151SR?
The K151SR has a continuous current rating of 200 Amps for both 15kV and 25kV voltage classes.
What is the momentary current rating for the K151SR?
The K151SR has a momentary current rating of 10kA Symmetrical for 10 cycles for both 15kV and 25kV voltage classes.
What are the 25kV operating voltage limits?
For the 25kV class, the maximum phase-to-ground operating voltage is 15.2kV, and the maximum phase-to-phase is 26.3kV.
What conductor sizes does the K151SR accommodate?
The K151SR accommodates conductor sizes from No. 4 solid through 4/0 stranded.
What are the 15kV operating voltage limits?
For the 15kV class, the maximum phase-to-ground operating voltage is 8.3kV, and the maximum phase-to-phase is 14.4kV.
What cable insulation diameters does the K151SR support?
The K151SR supports cable insulation diameters ranging from 0.575 inches through 1.220 inches.
What is the K151SR's primary application?
The K151SR is a separable insulated connector designed to connect a cable to another cable or apparatus. It is fully shielded and submersible.
How to Install the K151SR/151SR Straight Receptacle
This guide provides step-by-step instructions for preparing the cable, crimping the conductor, and installing the K151SR/151SR Straight Receptacle for high-voltage electrical connections.
Estimated time: 1h 30m
Tools needed:
Wire strippers, Crimp tool, Wire brush, Rag, Approved solvent, Multimeter
Supplies needed:
K151SR/151SR Straight Receptacle, Conductor Contact (male), Nylon Venting Rod, Lubricant (supplied), Crimp Chart, #14 AWG copper wire (or equivalent), Elastimold bail, Silicone grease
- De-energize and Prepare for Safety
Before beginning, ensure all apparatus is de-energized. Verify the absence of voltage using appropriate testing equipment. Read the entire installation instructions and gather all required tools and supplies. Inspect all parts for damage, proper rating, and compatibility with mating products. Failure to follow these safety instructions will result in serious or fatal injury.
- Prepare the Cable Jacket and Shield
For jacketed concentric neutral cable, cut and remove the cable jacket 8 inches from the cable end, ensuring sufficient neutral wires for grounding. For copper tape shield cable, cut and remove the cable jacket 7 1/2 inches from the cable end, then remove the copper tape shield 6 1/2 inches from the end of the cable. If using an ECS or MA grounding device, follow its specific instructions for outer jacket cut back.
- Remove Insulation and Crimp Conductor Contact
Remove 7/8 inch to 1 inch (or 1 3/4 inches to 1 7/8 inches for #1 stranded/compr. and #1/0 comp./solid aluminum cable) of cable insulation and conductive shield. Cut the insulation squarely; do not pencil. Wire brush bare aluminum conductors and immediately insert them into the crimp barrel, which contains inhibitor. Crimp the socket terminal onto the bared conductor, ensuring it remains fully seated. Start crimps at the crimp line and rotate each successive crimp 90 degrees. Refer to the supplied crimp chart. If using aluminum cable, carefully wipe excess inhibitor from the contact and cable insulation.
- Prepare Insulation and Clean Cable
Remove the semi-conductive shield 7 9/16 inches to 7 5/8 inches back from the end of the pin with a straight, smooth, 'squared' cut. DO NOT CUT OR NICK THE INSULATION. Pencil the insulation 1/8 inch. Clean the outer jacket and thoroughly clean the insulation to remove all traces of semi-conducting residue by wiping with a rag wet with an approved solvent, always wiping from the end of the cable toward the outer jacket. If using an ECS or MA grounding device, install it now following its instructions.
- Lubricate and Insert Cable into Receptacle
Remove the protective cap from the straight receptacle, keeping the cable insulation and receptacle clean. Apply the supplied lubricant sparingly to the cable and to the inside of the housing. DO NOT SUBSTITUTE other lubricants, as they may be harmful. Push the cable into the housing until the base of the pin chamfer is flush with the inside face of the receptacle. If the receptacle is not to be immediately connected, replace the protective cover (note: this cover is for dirt protection only and is not an insulating device; use an Elastimold insulating plug K150DP if insulation is required).
- Connect to Mating Plug (if applicable)
To connect to a mating plug, first lubricate the nose of the plug with silicone grease. Place the nylon rod into the receptacle face until it bottoms (approximately 1 3/4 inches), taking care not to cut the rod. Insert the plug assembly into the receptacle as far as possible, then pull out the nylon rod. Secure the electrical connection with an Elastimold bail.
- Ground the Cable
If an ELASTIMOLD grounding device is not being used, connect a length of #14 AWG or equivalent copper wire (customer supplied) through the grounding tab and twist tightly. Connect this grounding assembly to the system ground by merging it with the cable shield of each cable. Seal the grounding wires and connections to prevent corrosion.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.