ABB Installation Products 273RLR-G-5230 200 Amp, 25kV, Loadbreak Replacement Elbow Connector without Test Point, Repair Elbow…
UPC: 783786517749
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 200 Amp, 25kV loadbreak replacement elbow connector
- Extended length contact and housing (8-7/8" net gain)
- Compatible with 0.760" to 0.950" insulation diameter cables
- Accepts AWG #1/Solid to #1/0 Stranded or 42.41 mm² conductors
- Includes 00400X long Bi-Metal Contact for material compatibility
Specifications
Amperage Rating | 200 A |
Application | Designed for connecting to and operating 25kV Class, 125kV BIL apparatus |
Color | Black |
Conductor Range | #1 STR/COMPR AWG , 1/0 SOL/COMPT AWG |
Connection Type | Loadbreak Replacement Elbow Connector |
Current Rating | 200 A |
Environmental Conditions | Fully Submersible |
Insulation | True |
Material | Bi-Metal |
Material | Housing - EPDM-Rubber |
Series | 273RLR |
Size | Cable Insulation Diameter 0.760 inch to 0.950 inch |
Special Features | Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured insulation, insert and jacket. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes. Extended Length Housing and Compression Lug - plus 10-1/2 inch (266.7mm) |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Replacement Elbow Connector |
Voltage Rating | 15 kV |
Voltage Rating | 25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 2.4500 L |
Package Weight (Metric) | 1.1110 kg |

274AFLR3-B5230
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid/Compact.
K151SP-D0270
200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.890 inch to 1.220 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
376LR-J-2260
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
K151SR-D0270
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.890 inch to 1.220 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or kcmil Solid 250 or mmSquared 126.67.
168RLR-K-5270
200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
168ELR88110-5240
200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
168ELR-6689-5240
200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.665 inch to 0.895 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.Frequently Asked Questions
What material is the elbow constructed from?
The elbow is constructed from specially formulated, non-rigid ethylene propylene diene monomer (EPDM) rubber.
What type of contact is included with the 273RLR?
The 273RLR replacement elbow includes a long bi-metal contact, catalog number 00400X.
What is the purpose of the capacitive test point?
The capacitive test point allows for testing the circuit to determine the presence of voltage.
Where is the Elastimold 200 A elbow manufactured?
Elastimold 200 A repair and replacement elbows are designed, molded, and tested in Albuquerque, New Mexico, USA.
What standards does this product comply with?
The Elastimold 200 A loadbreak repair and replacement elbows are IEEE 386 compliant, ANSI certified, and Rural Utilities Service (RUS) accepted.
What is the cable insulation diameter range for 273RLR-G?
For the 273RLR-G, the cable insulation diameter ranges from 0.760 inches minimum to 0.950 inches maximum.
How much extra length does the 273RLR replacement elbow provide?
The 273RLR replacement elbow provides a net gain of 8 7/8 inches in length compared to a standard elbow.
What is the current rating of this elbow connector?
The Elastimold repair and replacement elbow connectors are rated for 200 A.
What is the voltage class of the 273RLR elbow?
The 273RLR replacement elbow connector is designed for a 25 kV voltage class.
What material is the elbow constructed from?
The elbow is constructed from specially formulated, non-rigid ethylene propylene diene monomer (EPDM) rubber.
How to Install and Connect the 273RLR/274RLR Loadbreak Replacement Elbow Connector
This guide provides step-by-step instructions for safely installing and wiring the 273RLR or 274RLR Loadbreak Replacement Elbow Connector, converting a livefront termination to deadfront for UD cable.
Tools needed:
Probe Wrench, Wire brush, Hotstick, Suitable sensing device (for 274RLR voltage test)
Supplies needed:
Replacement Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied), Hose Clamp, Copper wire (No. 14 AWG / 2.5mm), Silicone grease
- Prepare for Installation and Safety Checks
DANGER: Ensure all apparatus is de-energized before starting installation. Inspect all package contents for completeness and damage. Verify all components fit correctly with the cable and mating products. Check the probe threads by hand-threading into the compression lug; replace if resistance is encountered. Have all required tools ready and maintain cleanliness throughout the procedure.
- Remove Existing Livefront Terminator
DANGER: Confirm apparatus is de-energized. Remove the rubber cap from the existing terminator. Cut off the connector at the top of the terminator. Disconnect the ground lead from the base of the terminator. Carefully remove the terminator housing from the cable.
- Prepare the Cable
Train the cables to be straight and in-line with the bushing centerline. Measure and cut the cable to 10-1/2 inches from the bushing centerline. If the insulation shield measures less than 6-1/2 inches, proceed. If greater, consult an ELASTIMOLD representative. Remove 1-3/8 inches of cable insulation from the end, cutting squarely. DO NOT NICK THE CONDUCTOR.
- Install the Compression Lug
Wire brush the bare aluminum conductor thoroughly. Immediately install the compression lug, rotating it to spread the inhibitor. Position the lug so its contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe off any excessive inhibitor from the outside of the lug and cable.
- Assemble the Elbow Housing
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Keep the insulation clean. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess grease. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for about four turns before becoming snug. Tighten with the probe wrench until the wrench bends.
- Connect the Concentric Neutral
Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow and twist it tight, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Ensure adequate slack in the wires for elbow operation. Add the supplied hose clamp as shown and tighten it snugly, but do not overtighten.
- Connect the Elbow to the Bushing Plug
Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. This lubrication step MUST ONLY be performed if both the transformer and elbow are known to be de-energized. Once lubricated, the elbow can be operated per operating instructions, but DO NOT OPERATE BY HAND.
- Perform Voltage Test (274RLR Only)
For 274RLR models, remove the test point cap with a hotstick, peeling it off at an angle. WARNING: This is a capacitance device; do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points. Treat the elbow as energized until a "no voltage" indication is confirmed by other means. After testing, clean and lubricate the inside of the cap with silicone grease and replace it on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.