ABB - Installation Products K151SP-A0200 - 15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #4/Solid #3/mmSquared 21.14.

ABB Installation Products K151SP-A0200 15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order…

UPC: 783786505074


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K151SP-A0200 is a 15/25kV, 200 Amp deadbreak straight plug engineered for secure medium-voltage cable terminations in power distribution systems, substations, and industrial facilities. This component provides a reliable connection point for medium-voltage power systems where dependable and safe electrical terminations are critical. The deadbreak design ensures safe operation under load, allowing for connection and disconnection without de-energizing the system. Designed for compatibility with cable insulation diameters ranging from 0.575 inches to 0.740 inches, the K151SP-A0200 accommodates compressed stranded #4 AWG, solid #3 AWG, or 21.14 mm² conductors. The aluminum compression lug ensures robust conductor termination, maintaining electrical integrity under load. Note that bails are required for operation and must be ordered separately, as they are not included with the plug. This deadbreak straight plug is part of the K151SP series, optimized for medium-voltage applications requiring a 200 Amp current rating at 15/25kV. Its design facilitates direct and secure connections in power distribution infrastructure, supporting efficient and safe electrical system operation. The plug is constructed for durability and long-term performance in demanding environments, ensuring reliable operation in critical power distribution applications.
  • Voltage Rating: 15/25 kV
  • Current Rating: 200 A
  • Cable Insulation Diameter: 0.575" to 0.740"
  • Conductor Size: Compressed Stranded #4 AWG, Solid #3 AWG, or 21.14 mm²
  • Material: Aluminum Compression Lug

Specifications

Amperage Rating
200 A
Application
Designed to Terminate UD Cable having Concentric Neutral and Extruded installation shielding
Color
Black
Conductor Range
#4 STR/COMPR AWG , #3 SOL/COMPT AWG
Current Rating
200 A
Environmental Conditions
Fully Shielded, Fully Submersible
Insulation
True
Length
8.81 in
Length
223.774 mm
Material
Aluminum
Material
Housing - EPDM-Rubber
Series
K151SP
Size
Cable Insulation Diameter 0.575 inch to 0.740 inch
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for ground wire connection. Wide cable range with minimum number of sizes. No Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Plug
Voltage Rating
15 to 25 kV
Voltage Rating
15/25 kV
Width
2.55 in
Width
64.77 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle with Test Point, Bails are required but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #4/Solid #3/mmSquared 21.14.

K152SR-B0200

200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle with Test Point, Bails are required but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #4/Solid #3/mmSquared 21.14.
Single cable clamp 150-300mm2 for power terminal type 5

45000034

Single cable clamp 150-300mm2 for power terminal type 5
25kV 200 Amp, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

274ELR-K-5270

25kV 200 Amp, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Includes a copper compression lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41

K151SP-B2230

200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Includes a copper compression lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41
200 Amp, 25kV, Loadbreak Replacement Elbow Connector without Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

273RLR-G-5230

200 Amp, 25kV, Loadbreak Replacement Elbow Connector without Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.890 inch to 1.220 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

K151SP-D0270

200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.890 inch to 1.220 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.

376LR-J-2260

200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.890 inch to 1.220 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or kcmil Solid 250 or mmSquared 126.67.

K151SR-D0270

200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.890 inch to 1.220 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or kcmil Solid 250 or mmSquared 126.67.

Frequently Asked Questions

What is the impulse withstand rating for 25kV class?

For the 25kV voltage class, the impulse withstand (BIL) is 125kV.

What type of product is the K151SP?

The K151SP is a 15/25kV, 200 Amp Deadbreak Straight Plug.

What types of cables can the K151SP terminate?

It terminates UD cable with concentric neutral and extruded insulation shielding, and other cables with a proper Elastimold® cable shield adapter.

What conductor sizes does the K151SP accommodate?

The K151SP accommodates conductor sizes from No. 4 solid through 4/0 stranded.

What cable insulation diameters are supported?

It supports cable insulation diameters ranging from .575 inches to 1.220 inches.

What products is the K151SP compatible with?

The K151SP is designed to mate with Elastimold® K151T tee splices and K151SR straight receptacles.

What standards does the K151SP meet?

The K151SP meets ANSI/IEEE Standard 386, Latest Revision.

What is the maximum operating voltage for 15kV class?

For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV.

What is the continuous current rating?

The continuous current rating for both 15kV and 25kV voltage classes is 200 Amp.

What is the maximum operating voltage for 25kV class?

For the 25kV voltage class, the maximum phase-to-ground operating voltage is 15.2kV.

How to Install the K151SP Straight Plug

This guide provides step-by-step instructions for installing the K151SP Straight Plug on solid dielectric type cables for 15kV and 25kV class systems, including cable preparation, crimping, and connection to a mating receptacle.

Estimated time: 1h 30m

Tools needed:

Cable cutter, Wire strippers, Crimp tool, Wire brush, Rag, Approved solvent

Supplies needed:

K151SP Straight Plug kit (includes Conductor Contact, Nylon Venting Rod, Lubricant), Mating ELASTIMOLD receptacle (e.g., K151SR, K150T, K150DR, 156LR), ELASTIMOLD bail, #14 AWG copper wire (optional, for grounding), Silicone grease

  1. Ensure Safety and Prepare Cable Jacket

    DANGER: All apparatus must be de-energized during installation or removal of parts. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Inspect all parts for damage, rating, and compatibility with mating parts. For jacketed concentric neutral cables, cut and remove the cable jacket 8 inches from the cable end, ensuring sufficient concentric neutral wires for grounding. For copper tape shield cables, cut and remove the cable jacket 7-1/2 inches from the cable end, then remove the copper tape shield 6-1/2 inches from the end of the cable. If using an ECS or MA grounding device, follow its specific instructions for outer jacket cut back.

  2. Prepare Cable Insulation and Conductors

    Remove 7/8 to 1 inch (or 1-3/4 to 1-7/8 inches for #1 stranded/compressed and #1/0 compressed/solid aluminum cable) of cable insulation and conductive shield. Cut squarely; do not pencil the cut. Wire brush bare aluminum conductors immediately and insert them into the crimp barrel, which contains inhibitor.

  3. Crimp the Socket Terminal

    Crimp the socket terminal onto the bared conductor, holding the crimp barrel against the cable insulation. Refer to the crimp chart packed with the contact for specific instructions. Start the crimps at the crimp line imprinted on the crimp barrel and rotate each successive crimp or indent 90 degrees. Carefully wipe any excess inhibitor from the contact and cable insulation.

  4. Remove Semi-Conductive Shield and Clean Insulation

    Temporarily remove the plastic pin. Remove the semi-conductive shield to a point 7-3/4 to 7-13/16 inches back from the end of the socket with a straight, smooth, squared cut. DO NOT cut or nick the insulation. Replace the plastic pin. Pencil the insulation 1/8 inch. Clean the outer jacket and thoroughly clean the insulation to remove all traces of semi-conducting residue by wiping with a rag wet with an approved solvent. Always wipe from the end of the cable toward the outer jacket. If using an ECS or MA grounding device, install it following its appropriate instructions.

  5. Lubricate Cable and Plug Housing

    Slide the collar, smaller end first, onto each cable. Refer to the bailing instruction sheet. Keep the cable insulation and plug clean. Apply the supplied lubricant sparingly to the cable as shown and to the inside of the housing. DO NOT SUBSTITUTE other lubricants, as they may be harmful to this product or its mating product.

  6. Install Cable into Plug Housing

    Push the cable into the housing until the leading edge of the socket contact is flush with the front edge of the plug. Remove the plastic pin from the socket and discard it.

  7. Connect Plug to Mating Receptacle

    Lubricate the nose of the plug with silicone grease. Place the nylon rod into the receptacle face until it bottoms (approximately 1-3/4 inches), taking care not to cut the rod. Insert the plug assembly into the receptacle as far as possible. Pull out the nylon rod. Secure the electrical connection with an ELASTIMOLD bail; refer to Bailing Instruction Sheet (150TB-4).

  8. Complete Grounding Connection

    If an ELASTIMOLD grounding device is not being used, connect a length of #14 AWG (or equivalent) customer-supplied copper wire through the grounding tab and twist tightly. Connect the grounding assembly of the connector to the system ground by merging it with the cable shield of each cable. Seal the grounding wires and connections to prevent corrosion.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.