ABB Installation Products K151SR-A2240 200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not…
UPC: 075114411011
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 200 Amp, 15/25 kV voltage rating for medium-voltage applications
- Accommodates cable insulation diameters from 0.575" to 0.740"
- Copper compression lug for secure termination of 1/0 AWG stranded or 2/0 AWG solid compact conductors (53.49 mm²)
- Includes straight receptacle housing, pin connector, lubricant, installation instructions, and crimp chart
- Deadbreak elbow, straight receptacle connection type
Specifications
Amperage Rating | 200 A |
Application | Designed to connect a cable to another cable or apparatus |
Color | Black |
Conductor Range | 1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG , 53.49 mm2 |
Connection | Compression |
Environmental Conditions | Fully Shielded, Fully Submersible |
Insulation | True |
Length | 9.54 in |
Length | 242.316 mm |
Material | Housing - EPDM-Rubber |
Special Features | Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for ground wire connection. Wide cable range with minimum number of sizes. No Test Point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Straight Receptacle |
Voltage Rating | 15 to 25 kV |
Width | 2.74 in |
Width | 69.596 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

168FLR1-B5220
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit
K151SP-C2240
15kv 200 Amp Straight Plug No Test Point, No Seal, Cable Insulation Diameter 0.805 inch to 1.060 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 or Solid Compact 2/0 or 53.49 mm2.
262LR-D5240-S
15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.890-1.220 inches (22.61-30.99mm), Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed or 2/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 9.03 inches tall, 2.097 inch diameter. Includes Cold Shrink-Fit Jacket Seal Kit
168FLR1-C5270
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Conductor size 4/0 Stranded/Compressed AWG or 250 Solid/Compact kcmil. Bi-Metal Connector.
K656I-M0360
15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size Compressed Stranded 650 kcmil or Compacted Solid 750 kcmil.
K151SP-A2240
200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 1/0 or Solid Compact 2/0 or 53.49 mm2.
262LRJS-E5250
25kV, 200 Amps, Loadbreak Elbow, Built in Jacket Seal, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size 2/0 Stranded/Compressed, 3/0 Solid/Compact. With Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installation Instruction Sheet and Crimp Chart.
K655DLR-N0410-S
15/25kV, 600 Amp, Direct Test Elbow with Cold-Shrinkable Jacket Seal, DeadBreak, Cable Insulation 1.515-1.780 inches, Aluminum Compression Lug, Conductor Size 1000 Stranded/CompressedFrequently Asked Questions
Are copper compression lugs compatible with all conductors?
No, copper compression lugs are suitable for all copper conductors only.
What is the K151SR receptacle's primary use?
It is a fully shielded, fully submersible, separable insulated connector designed to connect a cable to another cable or apparatus.
What voltage systems is the K151SR suitable for?
The K151SR is suitable for use on both 15kV and 25kV systems.
What is the continuous current rating?
The K151SR has a continuous current rating of 200 Amps for both 15kV and 25kV voltage classes.
What cable insulation diameters does the K151SR accommodate?
It accommodates cable insulation diameters ranging from .575 in through 1.220 in.
What conductor sizes are compatible with the K151SR?
The K151SR will accommodate conductor sizes from No. 4 solid through 4/0 stranded.
When can the disconnectible feature be used?
The disconnectible feature can be used only when the circuit is de-energized.
What standards does the K151SR meet?
The K151SR meets ANSI/IEEE Standard 386, Latest Revision.
What is the max phase-to-ground operating voltage for 15kV?
For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV.
What is the max phase-to-ground operating voltage for 25kV?
For the 25kV voltage class, the maximum phase-to-ground operating voltage is 15.2kV.
How to Install the 151SR/K151SR Straight Receptacle
This guide provides detailed instructions for installing the 151SR/K151SR Straight Receptacle, including cable preparation, crimping, lubrication, and connection to mating Elastimold products for 15kV or 25kV class systems.
Estimated time: 1h 30m
Tools needed:
Wire cutters, Wire strippers, Wire brush, Crimp tool, Rag, Approved solvent
Supplies needed:
151SR/K151SR Straight Receptacle, Conductor Contact (male), Nylon Venting Rod, Lubricant (supplied), Crimp chart, Solid dielectric type cable, Inhibitor (in crimp barrel), Silicone grease, Elastimold bail, #14 AWG or equivalent copper wire, Corrosion prevention sealant, Elastimold insulating plug (K150DP) (optional)
- Ensure Safety and Inspect Components
Before starting, ensure all apparatus are de-energized. This product must be installed only by competent personnel trained in high voltage safety practices. Inspect all package contents for completeness and damage, and verify proper fit with cable and mating products. Remove any protective shipping covers and replace with appropriate HV insulated caps or connectors if the circuit will be submerged or energized before final connection. Note that a bailing arrangement is required when this product is used with any mating Elastimold deadbreak product.
- Prepare Cable Jacket
For jacketed concentric neutral cable, cut and remove the cable jacket 8 inches from the cable end, ensuring sufficient neutral wires for grounding. For copper tape shield cable, cut and remove the cable jacket 7 1/2 inches from the cable end, then remove the copper tape shield 6 1/2 inches from the cable end. Refer to ECS or MA grounding device instructions if applicable for outer jacket cut back.
- Prepare Conductor and Insulation
Remove 7/8 to 1 inch of cable insulation and conductive shield. For #1 stranded/compressed and #1/0 compressed/solid aluminum cable, remove 1 3/4 to 1 7/8 inches. Cut squarely, do not pencil. Wire brush bare aluminum conductors and immediately insert into the crimp barrel, which contains inhibitor.
- Crimp Socket Terminal
Crimp the socket terminal onto the bared conductor, ensuring the conductor remains fully seated in the connector. Refer to the crimp chart provided with the contact. Start crimps at the imprinted crimp line and rotate each successive crimp or indent 90 degrees. If using aluminum cable, carefully wipe any excess inhibitor from the contact and cable insulation.
- Prepare Semi-Conductive Shield and Clean Insulation
Remove the semi-conductive shield to a point 7 9/16 to 7 5/8 inches back from the end of the pin with a straight, smooth, squared cut. DO NOT CUT OR NICK THE INSULATION. Pencil the insulation 1/8 inch. Clean the outer jacket and thoroughly clean the insulation with an approved solvent, wiping from the cable end towards the outer jacket to remove all traces of semi-conducting residue. If using an ECS or MA grounding device, install it now following its specific instructions.
- Lubricate Receptacle and Cable
Remove the protective cap from the straight receptacle, keeping the cable insulation and receptacle clean. Sparingly apply the supplied lubricant to the cable (prepared insulation area) and to the inside of the receptacle housing. DO NOT SUBSTITUTE lubricants, as others may harm the product or its mating part.
- Insert Cable into Housing
Push the prepared cable into the receptacle housing until the base of the pin chamfer is flush with the inside face of the receptacle. If the receptacle is not to be immediately connected, replace the protective cover (note: shipping cover offers dirt protection only, not insulation; use an Elastimold insulating plug K150DP if insulation is required).
- Connect to Mating Plug
To connect to a mating plug, first lubricate the nose of the plug with silicone grease. Place the nylon rod into the receptacle face until it bottoms (approximately 1 3/4 inches), taking care not to cut the rod. Insert the plug assembly into the receptacle as far as possible. Pull out the nylon rod. Finally, secure the electrical connection with an Elastimold bail.
- Ground the Cable
If an ELASTIMOLD grounding device is not being used, connect a customer-supplied length of #14 AWG (or equivalent) copper wire through the grounding tab and twist tightly. Connect this grounding assembly of the connector to the system ground by merging it with the cable shield of each cable. Seal the grounding wires and connections to prevent corrosion.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.