Authorized ABB Distributor (Installation Products)
ABB - Installation Products K151SP-A2230 - 200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

ABB Installation Products K151SP-A2230 200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included…

UPC: 783786549023


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K151SP-A2230 is a 200 Amp, 15/25kV deadbreak elbow connector designed for reliable, high-voltage cable terminations in medium-voltage distribution systems. This straight plug connector accommodates cable insulation diameters from 0.575 inch to 0.740 inch, making it compatible with a range of AWG compressed stranded #1/solid 1/0 conductors (42.41 mm²). The copper compression lug ensures low-resistance electrical connections, critical for maintaining system efficiency and minimizing heat generation in high-current applications. This deadbreak elbow is part of ABB's K151SP series, a trusted line of deadbreak connectors engineered for safe, load-break operations in underground and overhead distribution networks. The deadbreak design allows for connection and disconnection under load without interrupting service, reducing downtime during maintenance or reconfiguration. Note that bails are required for proper installation but are not included; order separately to complete the assembly. Ideal for utility, industrial, and commercial applications, the K151SP-A2230 is commonly deployed in pad-mounted transformers, switchgear, and junction enclosures where space and reliability are paramount. Its compact straight plug design simplifies installation in tight spaces while ensuring compliance with ANSI/IEEE C119.4 and other industry standards for medium-voltage connectors. The connector’s robust construction and copper material provide long-term durability in harsh environmental conditions, including exposure to moisture, UV radiation, and temperature extremes. For specifiers and contractors, the K151SP-A2230 offers a cost-effective solution without sacrificing performance. Its compatibility with standard compression tools and fittings streamlines installation, while the deadbreak feature enhances operational flexibility. Always verify conductor size and insulation diameter compatibility before installation to ensure a secure, leak-tight connection.
  • 200 Amp current rating for medium-voltage applications
  • 15/25kV voltage rating for underground/overhead distribution
  • Deadbreak design allows load-break connections without service interruption
  • Copper compression lug for low-resistance, high-reliability terminations
  • Compatible with AWG #1/solid 1/0 (42.41 mm²) conductors
  • Straight plug design fits tight installation spaces
  • Requires separate bails for full assembly

Specifications

Amperage Rating
200 A
Application
Designed to Terminate UD Cable having Concentric Neutral and Extruded installation shielding
Color
Black
Conductor Range
#1 STR/COMPR AWG , 1/0 SOL/COMPT AWG
Connection
Compression
Environmental Conditions
Fully Shielded, Fully Submersible
Insulation
True
Length
8.81 in
Length
223.774 mm
Material
Housing - EPDM-Rubber
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for ground wire connection. Wide cable range with minimum number of sizes. No Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Plug
Voltage Rating
15 to 25 kV
Width
2.55 in
Width
64.77 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 1 AWG Stranded/Compressed, 1/0 AWG Solid/Compact. SG4 Option.

168FLR1-B0230-SG4

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 1 AWG Stranded/Compressed, 1/0 AWG Solid/Compact. SG4 Option.
15/25kV 200 Amp, Deadbreak Straight Receptacle (All Copper Lug), Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Conductor Size AWG Compressed Stranded #4/Solid #3/mmSquared 21.14.

K151SR-B2200

15/25kV 200 Amp, Deadbreak Straight Receptacle (All Copper Lug), Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Conductor Size AWG Compressed Stranded #4/Solid #3/mmSquared 21.14.
15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

K151SR-B0230

15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
200 Amp, 15kV, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. Includes 02800X Bi-Metal Contact.

167LRT-F5240

200 Amp, 15kV, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. Includes 02800X Bi-Metal Contact.
15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

K151SP-B0230

15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

167RLR-F-5230

200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

167RLR-H-5230

15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

167RLR-J-5270

200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

Frequently Asked Questions

What is the continuous current rating for the K151SP?

The K151SP has a continuous current rating of 200 Amps for both 15kV and 25kV voltage classes.

What is the maximum operating voltage for 25kV class?

For the 25kV voltage class, the maximum phase-to-ground operating voltage is 15.2kV.

What is the maximum operating voltage for 15kV class?

For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV.

Which industry standard does the K151SP meet?

The K151SP meets ANSI/IEEE Standard 386, Latest Revision.

What type of product is the K151SP?

The K151SP is a 15/25kV, 200 Amp Deadbreak Straight Plug without a test point.

What cable insulation diameters does the K151SP support?

It supports cable insulation diameters from 0.575 inches to 1.220 inches.

What conductor sizes does the K151SP accommodate?

The K151SP accommodates conductor sizes from No. 4 solid through 4/0 stranded.

What type of product is the K151SP?

The K151SP is a 15/25kV, 200 Amp Deadbreak Straight Plug without a test point.

What is the maximum operating voltage for 15kV class?

For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV.

What is the maximum operating voltage for 25kV class?

For the 25kV voltage class, the maximum phase-to-ground operating voltage is 15.2kV.

How to Install the K151SP Straight Plug

This guide provides step-by-step instructions for installing the K151SP Straight Plug onto solid dielectric type cable and connecting it to a mating receptacle or apparatus. Ensure all safety precautions are followed for high voltage electrical equipment.

Estimated time: 1h 30m

Tools needed:

Cable cutting tool, Wire strippers, Wire brush, Crimp tool, Rag, Measuring tape, Approved solvent, Elastimold bail

Supplies needed:

K151SP Straight Plug, Conductor contact (female), Nylon venting rod, Lubricant (supplied), Silicone grease, Solid dielectric type cable, Mating Elastimold receptacle, #14 AWG copper wire (optional), Sealing material (optional)

  1. Prepare the Cable Jacket

    DANGER: All apparatus must be de-energized during installation or removal of part(s). For Jacketed Concentric Neutral cable, cut and remove 8 inches of cable jacket, ensuring sufficient concentric neutral wires for grounding. For Copper Tape Shield cable, cut and remove 7-1/2 inches of cable jacket, then remove the copper tape shield 6-1/2 inches from the cable end.

  2. Remove Insulation and Conductive Shield

    Remove 7/8 inch to 1 inch (or 1-3/4 inches to 1-7/8 inches for #1 stranded/compressed and #1/0 compressed/solid aluminum cable) of cable insulation and conductive shield. Cut squarely, do not pencil. Wire brush bare aluminum conductors and immediately insert them into the crimp barrel which contains inhibitor.

  3. Crimp the Socket Terminal

    Crimp the socket terminal onto the bared conductor, holding the crimp barrel against the cable insulation. Refer to the crimp chart packed with the contact. Start the crimps at the crimp line imprinted on the crimp barrel and rotate each successive crimp or indent 90 degrees. Carefully wipe any excess inhibitor from the contact and cable insulation.

  4. Prepare the Insulation and Clean the Cable

    Temporarily remove the plastic pin. Remove the semi-conductive shield to a point 7-3/4 inches to 7-13/16 inches back from the end of the socket with a straight, smooth, 'squared' cut. DO NOT CUT OR NICK THE INSULATION. Replace the plastic pin. Pencil insulation 1/8 inch. Clean the outer jacket, and thoroughly clean the insulation with an approved solvent, wiping from the end of the cable toward the outer jacket, to remove all traces of semi-conducting residue. If using an ECS or MA grounding device, install it following its appropriate instructions.

  5. Lubricate the Cable and Plug Housing

    Slide the collar, smaller end first, onto each cable. Keep cable insulation and plug clean. Apply the supplied lubricant sparingly to the cable as shown and to the inside of the housing. DO NOT SUBSTITUTE; other lubricants may be harmful to this product or its mating product.

  6. Insert the Cable into the Plug Housing

    Push the cable into the housing. The leading edge of the socket contact should be flush with the front edge of the plug. Remove the plastic pin from the socket and discard it.

  7. Connect the Plug to a Mating Receptacle

    Lubricate the nose of the plug with silicone grease. Place the nylon rod into the receptacle face until it bottoms (approximately 1-3/4 inches). Exercise care to ensure the nylon rod is not cut while mating parts, which could leave material inside the interface. Insert the plug assembly into the receptacle as far as possible. Pull out the nylon rod. Secure the electrical connection with the aid of an ELASTIMOLD bail. CAUTION: A bailing arrangement is required when this product is used with any mating Elastimold deadbreak product.

  8. Connect the Grounding Assembly (Optional)

    If an ELASTIMOLD grounding device is not being used, connect a length of #14 AWG (or equivalent) copper wire (customer supplied) through the grounding tab and twist tightly. Then connect the grounding assembly of the connector to the system ground by merging with the cable shield of each cable. Seal the grounding wires and connections to prevent corrosion.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.