ABB - Installation Products R2T15J2-N2360-B3 - Ranger2 Termination, Outdoor, 15kv, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch (21mm-35mm), Connector Type - N2 - Copper 2-Hole Spade #2-1250 kcmil, 650 Stranded/Compressed or 750 Compact/Solid, B3 - Cable Mounting Bracket - Stainless Steel - 1.45 inch - 1.95 inch (37-50mm)

ABB Installation Products R2T15J2-N2360-B3 Ranger2 Termination, Outdoor, 15kv, Cable Type - Concentric Neutral/Jacketed Concentric…

UPC: 075114424462


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Termination Kit, SKU R2T15J2-N2360-B3, provides reliable outdoor termination for 15kV medium-voltage cables with concentric neutral or jacketed concentric neutral construction. Designed for cable insulation diameters from 0.84 inches to 1.38 inches (21mm-35mm), this kit ensures compatibility with a broad range of medium-voltage applications, including popular XLP and EPR cable types. The kit features the N2 copper 2-hole spade connector, engineered to handle cable sizes from #2 AWG to 1250 kcmil. It supports stranded/compressed conductors up to 650 kcmil and compact/solid conductors up to 750 kcmil, delivering a robust electrical connection for high-performance installations. The B3 stainless steel cable mounting bracket (1.45"-1.95" diameter range) offers corrosion-resistant support, ideal for outdoor environments. The Ranger2 termination leverages shrink-fit technology and Elastimold’s pull-down jacket seal feature, enabling installation in restricted spaces and free-hanging applications. Its non-tracking silicone housing delivers superior weathering resistance and long-term service life, with four sheds for enhanced creepage and strike distances. Optional insulating silicone sleeves are available for applications requiring additional creepage or wildlife protection. Key electrical ratings include a maximum design voltage to ground of 9.5kV, a lightning impulse withstand of 110kV crest, and a 10-second wet withstand of 45kV. The termination is designed for ambient temperatures from -22°F to +149°F (-30°C to +65°C) and altitudes up to 3,300 feet (1,005 meters), making it suitable for diverse field conditions. With IEEE Class 1A outdoor classification and a power system frequency range of 48-62Hz, this kit meets the demands of modern medium-voltage systems.
  • 15kV outdoor termination for concentric neutral or jacketed concentric neutral cables
  • Compatible with cable insulation diameters from 0.84" to 1.38" (21mm-35mm)
  • N2 copper 2-hole spade connector supports #2 AWG to 1250 kcmil conductors
  • Non-tracking silicone housing with four sheds for superior weathering resistance
  • Stainless steel B3 bracket (1.45"-1.95" diameter) for corrosion-resistant outdoor mounting

Specifications

Application
Cable Termination, Outdoor Application, 15kV
Cable Type
Concentric Neutral Wire
Color
Gray
Conductor Size
650 STR/COMPR kcmil , 750 SOL/COMPT kcmil
Earthing
Products Includes Their Own Grounding System
Mounting
Product Need to have Cable Holder (not included)
Number Of Terminals
(1) Singe Phase
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for LC Shield Tape Shield/Wire Over Tape Shield. includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 1000.

R2T15L4-N0410

Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for LC Shield Tape Shield/Wire Over Tape Shield. includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 1000.
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Tinned Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 1250 kcmil.

R2T15J4-N2440

Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Tinned Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 1250 kcmil.
Outdoor Ranger2 Cable Termination. 35kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - .84 inch - 1.38 inch. Aluminum 1-Hole Spade #2-500 kcmil, Conductor 1/0 Stranded/Compressed AWG or 2/0 Compact/Solid AWG

R2T35M2H0240

Outdoor Ranger2 Cable Termination. 35kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - .84 inch - 1.38 inch. Aluminum 1-Hole Spade #2-500 kcmil, Conductor 1/0 Stranded/Compressed AWG or 2/0 Compact/Solid AWG
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Tinned Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 300 -Stranded or Compressed 350 kcmil, Compact or Solid 400 kcmil.

R2T28M2-H0300

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Tinned Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 300 -Stranded or Compressed 350 kcmil, Compact or Solid 400 kcmil.
69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 1 (Bore Diameter 1.55 inch, Insulation Range 1.65 to 1.9 inch), Connection Type - 2-Hole NEMA, Connector Type - Aluminum, Conductor Size Code 41P - 1.101 to 1.152 inch, Metallic Screen Kit - 1/0 Bonding Cable 6 foot with Two Split Bolts, Armor Kit - Heat Shrink, No Bracket Required

69TCT212141PBBN

69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 1 (Bore Diameter 1.55 inch, Insulation Range 1.65 to 1.9 inch), Connection Type - 2-Hole NEMA, Connector Type - Aluminum, Conductor Size Code 41P - 1.101 to 1.152 inch, Metallic Screen Kit - 1/0 Bonding Cable 6 foot with Two Split Bolts, Armor Kit - Heat Shrink, No Bracket Required
Ranger2 Termination for 35KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neutral and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 1250.

R2T35J4-N0440

Ranger2 Termination for 35KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neutral and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 1250.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0. Cable Mounting Bracket - Stainless Steel, 0.80 to 1.25 inch.

R2IT15M1-N2240-B1

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0. Cable Mounting Bracket - Stainless Steel, 0.80 to 1.25 inch.
69kV, Transmission Cable Terminator, Base and Two Top Module, Housing Size 0 with Bore Diameter 1.35 inch with Insulation Range of 1.45 to 1.7 inch, Connection Type 2 - 2 Hole NEMA, Connector Type - Copper, Conductor Size Code 33P: 0.781 - 0.815 inch, Metallic Screen Kit - Not Required, Armor Kit - Jacketing Tape and Mastic, No Bracket Required

69TCT302233PNAN

69kV, Transmission Cable Terminator, Base and Two Top Module, Housing Size 0 with Bore Diameter 1.35 inch with Insulation Range of 1.45 to 1.7 inch, Connection Type 2 - 2 Hole NEMA, Connector Type - Copper, Conductor Size Code 33P: 0.781 - 0.815 inch, Metallic Screen Kit - Not Required, Armor Kit - Jacketing Tape and Mastic, No Bracket Required

Frequently Asked Questions

Where can I find installation instructions for R2T15?

Installation instructions are IS-1134 for R2T15J, IS-1135 for R2T15M, and IS-1136 for R2T15L.

What is the voltage rating of the R2T15 termination?

The R2T15 cable termination has a voltage rating of 15 kV.

What cable insulation diameters does the R2T15 support?

It supports insulation diameters from 0.64 inches (16 mm) to 2.10 inches (53 mm).

What AWG cable sizes are compatible with R2T15?

The R2T15 termination accommodates cable sizes from #2 AWG through 1250 kcmil.

What cable types are compatible with the R2T15 termination?

The units accommodate popular XLP and EPR cable types and shield constructions.

What is the operating temperature range for the R2T15?

The ambient temperature range for operation is -22 to +149 °F (-30 to +65 °C).

What is the maximum altitude for R2T15 installation?

The R2T15 termination can be installed at a maximum altitude of 3300 feet (1005 m).

What is the power system frequency range for R2T15?

The power system frequency range for the R2T15 is 48 to 62 Hz.

How is the R2T15 cable termination mounted?

The R2T15 can be mounted free hanging or with an optional support bracket.

What is the maximum design voltage to ground for R2T15?

The maximum design voltage to ground for the R2T15 termination is 9.5 kV.

How to Install the R2T15J2 Cable Termination

This guide provides step-by-step instructions for installing the R2T15J2 15kV Ranger 2 Cable Termination on concentric and jacketed concentric neutral cables for indoor/outdoor applications. Ensure all apparatus are de-energized before beginning installation.

Estimated time: 1h

Tools needed:

Wire Strippers, Crimping Tool, Approved Solvent, Aluminum Oxide Abrasive (optional, grit 120 or finer), Vinyl Tape, Binding Wire (optional), Gloves

Supplies needed:

Silicone Rubber Termination, Silicone Lubricant, Grey Silicone Rubber Tape, Sealing Mastic, Terminal Lug or Connector, Silicone Grease, Cable Support Bracket (Optional, B3 style)

  1. Prepare the Cable

    Train the cable into position and cut it to the required length for installation, allowing sufficient neutral wire length for grounding. Strip the cable jacket, expose neutral wires, and remove the semi-conductive insulation shield and primary insulation to the specified dimensions. For R2T15J2, expose 7.5 inches (190mm) of primary insulation, plus additional conductor length to accommodate the terminal lug barrel depth and crimping growth. Carefully wrap one band of sealing mastic around the cable jacket 1/4 inch (6mm) from the jacket end, using 50% stretch, and cut flush without overlap. Bend the neutral wires back over the mastic and secure them to the cable jacket 4-6 inches (100-150mm) from the cut edge using vinyl tape or binding wire. Apply a second mastic band over the neutral wires and the first mastic, using 50% stretch, and cut flush. Wrap two half-lapped layers of vinyl tape around the mastic seal, maintaining the 1/4 inch (6mm) dimension.

  2. Install the Terminal Lug or Connector

    Position the terminal lug or connector onto the prepared conductor and crimp it according to the manufacturer's directions. Do not crimp the last 1/4 inch to 3/8 inch of the connector. After crimping, remove any excess oxide inhibitor and sharp crimp flashings.

  3. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation with an approved solvent, ensuring the solvent does not touch the semi-conductive insulation shield. If necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation, being careful not to reduce the cable insulation diameter below the kit's allowed range. Do not use abrasive on the semi-conductive insulation shield.

  4. Install the Termination Body

    Apply a band of grey silicone rubber tape around the base of the terminal lug to create a track-resistant moisture seal. If the lug barrel diameter is smaller than the cable primary insulation, build up the tape band to match the insulation diameter. Liberally coat the edge of the semi-conductive insulation shield with silicone grease to fill the step at the cut-off. For lower terminations with a fold-down skirt, pull the loose end of the removable core through the top of the termination until the core is flush with the bottom. Slide the termination body onto the cable, aligning its bottom edge with the leading edge of the mastic seal. Carefully remove the internal core by unwinding it counter-clockwise from the loose end, ensuring the termination body remains butted against the mastic seal without pushing or pulling the assembly. Apply a thin film of silicone lubricant to the skirt and mastic seal area (do not lubricate skirt tabs). Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining grey silicone rubber tape, overlapping the termination insulator by approximately 1 inch and extending the tape wrapping over a non-crimped region of the lug/connector barrel with a half-lap configuration. Twist the concentric neutral wires together and connect them to the system ground. Finally, confirm that the High-K step does not exceed 1.5 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.