Authorized ABB Distributor (Installation Products)
ABB - Installation Products 69TCJN1RA46PVEJNB - 69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930. Connector Type - Aluminum/No connector Requiered, Connector Code 46P - Conductor Diameter Range - 1.328-1.377 inch (33.73-34.98mm), Heatsink Size/Bore - V - 2.046 inch Diameter. Type Shield - E - Lead, Metallic Screen Continuity Kit - J - 4/0 Bonding Cable 4 foot quantity 3 without split bolts, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - HeatShrink

ABB Installation Products 69TCJN1RA46PVEJNB 69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1…

UPC: 783786199655


Documents & Media
Specification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Installation Products 69TCJN1RA46PVEJNB is a factory-molded, 69 kV transmission cable joint engineered for high-voltage solid dielectric cable systems. Designed for 46 kV through 138 kV class applications, this joint features a non-shieldbreak housing (Style 1) with optimized pre-molded stress control and heat transfer capabilities, ensuring maximum insulation and shielding integrity. The joint accommodates conductor diameters between 1.328–1.377 inches (33.73–34.98 mm), with a housing size R bore diameter of 1.930 inches at the jacket/insulation transition and a 2.046-inch diameter heatsink bore (Size V). No external connector is required, as specified by Connector Code 46P, simplifying installation and reducing labor time. The Type E lead shield ensures metallic screen continuity, while the metallic screen continuity kit includes three 4/0 bonding cables (4-foot length) without split bolts (Code J), providing secure grounding. The outer jacket restoration uses a HeatShrink kit (Code B) for environmental protection and long-term reliability. This joint is optimized for transmission cable systems where armor continuity is not required (Armor Kit Code N), making it ideal for utilities and industrial power distribution. Factory-molded and 100% electrically tested, the 69TCJN1RA46PVEJNB eliminates the need for field molds, tape-wrapping machinery, or pre-stretch equipment, reducing on-site time and training requirements. The extended shelf life enables instant availability of spares, ensuring operational readiness.
  • Factory-molded for maximum insulation and shielding integrity
  • Accommodates conductor diameters 1.328–1.377 inches (33.73–34.98 mm)
  • Non-shieldbreak housing (Style 1) with optimized stress control and heat transfer
  • No external connector required (Connector Code 46P)
  • Includes Type E lead shield and three 4/0 bonding cables (4-foot length) for metallic screen continuity

Specifications

Application
For use on Solid Dielectric Cables - providing permanent, fully-shielded, fully submersible cable joints for direct burial or vault applications
Color
Black
Conductor Range
1.328 to 1.377 in
Connection
Compression
Connection Type
No Connector Required
Insulation
Yes
Material
EPDM Rubber
Material
Aluminum, Lead, HeatShrink
Number Of Conductors
2
Series
69TCJN1RA46PVEJNB
Size
Housing Size R, Heatsink Size V
Special Features
Each Cable Joint is produced exactly to design, producing a quality not possible with field molding equipment or tape. Electrically tested in the factory to ensure consistent quality. Molding is done in the factory, reducing on-site time - no penciling of cable installation required. Easy to learn installation procedure. Field molds, wrapping machines or pre-stretch not required, and a low-cost assembly tool is available. Extended shelf life enables instant availability of spares. Designed with optimized pre-molded stress control and heat transfer capabilities
Standard
ANSI C119.4, Shield Test IEEE 592
Temperature Rating, Maximum
194 F
Temperature Rating, Maximum
90 C
Temperature Rating, Minimum
194 F
Temperature Rating, Minimum
90 C
Type
Transmission Cable Joint - Non-Shieldbreak
Voltage Rating
69 kV
Package Weight (Imperial)
25.2500 L
Package Weight (Metric)
11.4530 kg
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930. Connector Type - Aluminum/no connector required, Connector Code 46P - Conductor Diameter Range - 1.328-1.377 inch (33.73-34.98mm), Heatsink Size - N - not required, Heatsink Bore - N - not required. Type Shield - N - not required, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - N - not required

69TCJS1RA46PNNNNNN

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930. Connector Type - Aluminum/no connector required, Connector Code 46P - Conductor Diameter Range - 1.328-1.377 inch (33.73-34.98mm), Heatsink Size - N - not required, Heatsink Bore - N - not required. Type Shield - N - not required, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - N - not required
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.

15PCJ1F2250

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded #1/Solid 1/0.

15PCJ1F2230

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

15PCJ1F2240

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

15PCJ1F2270

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded #2/Solid #1.

15PCJ1F2220

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded #2/Solid #1.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded #3/Solid #2.

15PCJ1F2210

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded #3/Solid #2.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.

15PCJ1F1250-1230

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.

Frequently Asked Questions

What is the maximum system voltage for 138 kV class joints?

The maximum system voltage for 138 kV class TCJ joints is 145 kV.

What is the BIL rating for 69 kV class joints?

The Basic Impulse Level (BIL) rating for 69 kV class joints is 350 kV (1.2 x 50μs; 10 positive, 10 negative impulses).

What is the BIL rating for 138 kV class joints?

The Basic Impulse Level (BIL) rating for 138 kV class joints is 650 kV (1.2 x 50μs; 10 positive, 10 negative impulses).

Are field molds or tape wrapping required for installation?

No, field molds, wrapping machines, or pre-stretch are not required for installation. The easy-to-learn procedure eliminates these needs.

Do TCJ joints offer a shield break option?

Yes, a shield break option is provided for cross bonding purposes on Style 4 joints. Joints may also be installed as a standard shield break.

What material is the pre-molded housing made from?

The void-free joint housing consists of peroxide-cured EPDM insulation bonded under pressure to peroxide-cured molded semi-conductive elements.

Are TCJ transmission cable joints factory tested?

Yes, all TCJ transmission cable joints are factory molded and factory tested to ensure consistent quality and maximum reliability.

What voltage systems are TCJ joints designed for?

TCJ transmission cable joints are designed for 46 kV through 138 kV class systems.

What cable types are compatible with TCJ joints?

TCJ transmission cable joints are designed for use on solid dielectric cables.

What cable insulation diameters do TCJ joints support?

For Style 1 (through 69 kV), insulation diameters range from 1.43 inches to 2.58 inches. For Style 4 (through 138 kV), they range from 2.25 inches to 3.62 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.