ABB - Installation Products 69TCJN1P - 69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Only, Housing Size P Bore Diameter at Jacket/Insulation Transition 1.570.
ABB - Installation Products

69TCJN1P

UPC: 783786951024


Documents & Media
Specification SheetManufacturer Product Website

Contact for Pricing

Overview

The ABB 69TCJN1P is a transmission cable joint housing designed for 69 kV applications, specifically for non-shieldbreak installations. This housing is part of ABB’s Installation Products catalog and is designated as Housing Style 1, Size P, with a bore diameter of 1.570 inches at the jacket/insulation transition. The non-shieldbreak design ensures continuity of the cable’s shielding system, reducing the risk of electrical interference and improving system reliability. This housing is intended for use in high-voltage transmission systems where cable joints require robust, non-conductive protection. It is compatible with standard 69 kV cable configurations and is engineered to maintain structural integrity under typical operating conditions. The housing’s size and bore dimensions are optimized for seamless integration with existing cable joint assemblies, ensuring a secure and stable connection. The ABB 69TCJN1P is a critical component in transmission infrastructure, supporting the safe and efficient transfer of electrical power. It is manufactured by ABB, a global leader in power and automation technologies, ensuring compatibility with ABB’s broader portfolio of transmission and distribution products. This housing is part of a standardized system, making it suitable for utility, industrial, and commercial applications where 69 kV cable joints are deployed.
  • 69 kV rated transmission cable joint housing
  • Non-shieldbreak design for continuous shielding
  • Housing Style 1, Size P with 1.570" bore diameter
  • Compatible with standard 69 kV cable configurations
  • Manufactured by ABB Installation Products

Specifications

Application
For use on Solid Dielectric Cables - providing permanent, fully-shielded, fully submersible cable joints for direct burial or vault applications
Color
Black
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Series
69TCJN
Size
Size P Bore Diameter at Jacket/Insulation Transition 1.570
Special Features
Each Cable Joint is produced exactly to design, producing a quality not possible with field molding equipment or tape. Electrically tested in the factory to ensure consistent quality. Molding is done in the factory, reducing on-site time - no penciling of cable installation required. Easy to learn installation procedure. Field molds, wrapping machines or pre-stretch not required, and a low-cost assembly tool is available. Extended shelf life enables instant availability of spares. Designed with optimized pre-molded stress control and heat transfer capabilities
Standard
ANSI C119.4, Shield Test IEEE 592
Temperature Rating, Maximum
194 F
Temperature Rating, Maximum
90 C
Temperature Rating, Minimum
194 F
Temperature Rating, Minimum
90 C
Type
Transmission Cable Joint - Non-Shieldbreak
Voltage Rating
69 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Size N Bore Diameter at Jacket/Insulation Transition 1.390. Connector Type - Copper, Connector Code 30P - Conductor Diameter Range - .636-.686 inch (16.15-17.42mm), Heatsink Size/Bore - E - .921 inch Diameter. Type Shield - B - Copper 1/3 Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - A - Jacket Tape 5 Rolls

69TCJN1N230PEBNNA

69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Size N Bore Diameter at Jacket/Insulation Transition 1.390. Connector Type - Copper, Connector Code 30P - Conductor Diameter Range - .636-.686 inch (16.15-17.42mm), Heatsink Size/Bore - E - .921 inch Diameter. Type Shield - B - Copper 1/3 Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - A - Jacket Tape 5 Rolls
69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930. Connector Type - Aluminum/No connector Requiered, Connector Code 46P - Conductor Diameter Range - 1.328-1.377 inch (33.73-34.98mm), Heatsink Size/Bore - V - 2.046 inch Diameter. Type Shield - E - Lead, Metallic Screen Continuity Kit - J - 4/0 Bonding Cable 4 foot quantity 3 without split bolts, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - HeatShrink

69TCJN1RA46PVEJNB

69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930. Connector Type - Aluminum/No connector Requiered, Connector Code 46P - Conductor Diameter Range - 1.328-1.377 inch (33.73-34.98mm), Heatsink Size/Bore - V - 2.046 inch Diameter. Type Shield - E - Lead, Metallic Screen Continuity Kit - J - 4/0 Bonding Cable 4 foot quantity 3 without split bolts, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - HeatShrink
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.

15PCJ1F2250

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded #1/Solid 1/0.

15PCJ1F2230

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

15PCJ1F2240

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

15PCJ1F2270

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded #2/Solid #1.

15PCJ1F2220

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded #2/Solid #1.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded #3/Solid #2.

15PCJ1F2210

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded #3/Solid #2.

Frequently Asked Questions

What cable insulation diameters are compatible with TCJ joints?

For Style 1 (through 69 kV), insulation diameters are 1.43 inches to 2.58 inches. For Style 4 (through 138 kV), diameters are 2.25 inches to 3.62 inches.

What voltage systems are TCJ cable joints designed for?

TCJ transmission cable joints are designed for 46 kV through 138 kV class systems.

What are the maximum system voltages for TCJ joints?

TCJ joints for 69 kV class systems have a maximum system voltage of 72.5 kV, while 138 kV class systems have a maximum of 145 kV.

What is the minimum corona extinction voltage for 138 kV joints?

The minimum corona extinction voltage for 138 kV class joints is 120 kV (at 3 pC sensitivity).

What is the maximum continuous conductor temperature?

The maximum continuous conductor temperature for these joints is 90 °C.

What is the BIL rating for 69 kV class joints?

The Basic Impulse Level (BIL) rating for 69 kV class joints is 350 kV.

What is the minimum corona extinction voltage for 138 kV joints?

The minimum corona extinction voltage for 138 kV class joints is 120 kV (at 3 pC sensitivity).

What is the maximum continuous conductor temperature?

The maximum continuous conductor temperature for these joints is 90 °C.

What voltage systems are TCJ cable joints designed for?

TCJ transmission cable joints are designed for 46 kV through 138 kV class systems.

What cable insulation diameters are compatible with TCJ joints?

For Style 1 (through 69 kV), insulation diameters are 1.43 inches to 2.58 inches. For Style 4 (through 138 kV), diameters are 2.25 inches to 3.62 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.