ABB Installation Products 15PCJ1F2250 15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…
UPC: 075114213233
Contact for Pricing
Minimum Qty: 30
Multiplier: 30
*Contact for lower quantities*
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15kV voltage rating
- Single-piece housing for simplified installation
- Accommodates cable insulation diameter: 0.640" to 0.820"
- Suitable for copper conductors
- Supports AWG stranded 2/0 and solid 3/0 conductor sizes
Specifications
Application | For Direct Burial, Vault, Submersible and Other Severe Service Applications |
Color | Black |
Conductor Range | 2/0 STR AWG , 3/0 SOL AWG |
Connection | Compression |
Insulation | Yes |
Material | Copper |
Material | EPDM Rubber |
Number Of Conductors | 2 |
Series | 15PCJ1F |
Size | 10-1/4 inch long |
Size | 0.640 inch to 0.820 inch |
Special Features | Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable |
Standard | IEEE Standard 404 |
Type | Power Cable Joint |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 0.8500 L |
Package Weight (Metric) | 0.3860 kg |

15PCJ1H2250
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.
15PCJ1F2230
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
15PCJ1F2240
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
15PCJ1F2270
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
15PCJ1F2220
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded #2/Solid #1.
15PCJ1F2210
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded #3/Solid #2.
15PCJ1F1250-1230
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
15PCJ1F1240
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.Frequently Asked Questions
What is the difference between PCJ Style 1 and Style 2?
Style 1 is for straight splicing of two similar cables. Style 2 has separate cable adapters for transition splicing between different cable sizes.
What are the installation environments for PCJ cable joints?
PCJ power cable joints can be installed in direct-burial, underground vault, and even overhead applications.
What types of conductors are compatible with PCJ joints?
These joints can be used with copper or aluminum conductors, accommodating a wide range of sizes up to 1250 kcmil.
What voltage classes are available for PCJ joints?
Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.
What is the continuous current rating of PCJ joints?
The continuous current rating of PCJ power cable joints is equal to that of the cable rating.
What are Elastimold PCJ power cable joints used for?
They are used for straight splicing of two similar cables or transition splicing of different cable sizes, up to 1250 kcmil, in new or existing installations.
What type of connector is included for aluminum conductors?
The kit includes an aluminum compression connector suitable for splicing aluminum-to-aluminum or aluminum-to-copper conductors.
Can copper connectors be used with aluminum conductors?
No, copper compression connectors are suitable for copper-to-copper connections only and should not be used on aluminum conductors.
What is the short-time current rating of PCJ joints?
The short-time current rating is equal to that of the cable rating, up to 35 kA.
What is the difference between PCJ Style 1 and Style 2?
Style 1 is for straight splicing of two similar cables. Style 2 has separate cable adapters for transition splicing between different cable sizes.
How to Install the 15PCJ1F2250 Single Core Joint
This guide provides step-by-step instructions for the permanent installation of the 15PCJ1F2250 single core joint. It covers cable preparation, conductor connection, and restoration for extruded solid dielectric cables.
Estimated time: 2h
Tools needed:
Wire strippers, Utility knife, Measuring tape or ruler, Wire brush, Crimp tool (specific to conductor splice), Soldering iron (if not using constant force springs), Heat gun, Sandpaper, Clean cloth
Supplies needed:
Joint Housing (15PCJ1F2250), PVC tape (different colors recommended), Conductor splice (copper or aluminum compression type), Lubricant (supplied with joint), Cleaning solvent, Mastic tape, Heat shrink (supplied with joint), Flat copper braid, Constant force springs (optional, alternative to solder)
- De-energize and Prepare Work Area
DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products in the work area. Inspect all parts for damage, rating, and compatibility with mating parts. Ensure the package contents are complete and undamaged. Have all required tools at hand and maintain cleanliness throughout the procedure.
- Prepare Cables - Remove Jacket and Metallic Shield
Train the cables into their final position and square cut them, leaving approximately 5mm between cables. Store the heat shrink on either cable. Remove the jackets of both cables to the dimensions specified in the provided table (A, B, C). Carefully remove the cable metallic tape screen for the distance shown and secure the ends with PVC tape. Keep the PVC tape on the copper tape, ensuring it does not overlap onto the non-metallic screen.
- Prepare Cables - Remove Non-Metallic Screen
WARNING: DO NOT NICK, CUT, OR DAMAGE THE INSULATION SURFACE OR CONDUCTOR STRANDS. Carefully remove the cable non-metallic screen from both cables to the point specified (dimension D from the table). Bevel the edge of Cable 1. Cut the insulation to the conductor to dimension 'E' (indicated in the table) from the end of both cables, but DO NOT remove the insulation. Install a PVC tape marker on Cable 2 to dimension 'B' to locate the splice later.
- Temporarily Store Joint Housing
Beginning at the jacket and proceeding 10mm beyond the end of the metallic screen, apply one layer (half lapped) of PVC tape over the metallic screen. Install a different color PVC tape marker on Cable 1 to dimension 'B' to locate the splice later. Lubricate both cable entrances of the splice housing. Clean and lubricate the insulation, cable non-metallic screen, and PVC taped portion of the cable metallic tape screen on Cable 1. Store the housing onto Cable 1 up to the jacket. DO NOT STORE SPLICE HOUSING ON EXPOSED METALLIC TAPE SHIELD. WARNING: The forward edge and any other sharp edges of the metallic screen must be covered with PVC tape to prevent damage to the joint housing when storing it on the PVC taped portion of the cable.
- Remove Cable Insulation
Remove cable insulation from both cables to dimension 'E' (from the table). DO NOT CUT OR NICK THE CABLE INSULATION OR CONDUCTOR during this process.
- Install Conductor Splice
Wire brush the exposed conductors of both cables. Immediately insert the conductors into the conductor splice, ensuring both conductors are fully seated. DO NOT CRIMP yet. Check the distance between insulations; if it exceeds the “Before” dimension (from the table), DO NOT PROCEED. Review instructions and redo assembly. Crimp the conductor splice according to the crimp chart provided. Remove any sharp protrusions or burrs. Metal chips or filings must be removed from the splice joint assembly area prior to sliding the joint. Wipe off all excess inhibitor. Check the distance between cable insulations again; if it exceeds the “After” dimension (from the table), DO NOT PROCEED. Review instructions and redo assembly.
- Clean and Lubricate Core
WARNING: REMOVE ALL CONTAMINANTS FROM THE SURFACE OF THE INSULATION. Clean the conductor, connector, and Cable 2 insulation surfaces with cleaning solvent and a clean cloth, always wiping towards the screen end. Lubricate cable insulation surfaces using the lubricant supplied, always wiping toward the screen end to provide a build-up or ramp of lubricant at the edge of the non-metallic screen.
- Install Joint Housing
Slide the joint housing over the crimp connector into its final position. Measure the distance between the joint housing and the PVC tape marker; the distance “X” should be equal on each side of the joint housing. Remove the PVC tape applied in Step C to expose 25mm of copper tape.
- Restore Screen
Wrap flat copper braid around each joint housing, continuing the ends over the metallic tape screen for 20mm on each side. Attach each end of the copper braid to the metallic tape screen by soldering or by using a constant force spring.
- Restore Outer Jacket
Lightly sand the outer surface of the jacket of both cables for a distance of 130mm. Heat both sanded areas for approximately 15 seconds; DO NOT BURN CABLES. Wrap two layers of mastic tape at the edge of the jacket on both cables. Position the heat shrink from Cable 1 over the center of the assembly and shrink it, starting at the center and working toward the ends.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.