Authorized ABB Distributor (Installation Products)
ABB - Installation Products 15PCJ1F2210 - 15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded #3/Solid #2.

ABB Installation Products 15PCJ1F2210 15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 783786030125


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Minimum Qty: 30

Multiplier: 30

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 15kV Power Cable Joint Style 1 (SKU: 15PCJ1F2210) is engineered for reliable power cable termination in medium voltage applications. This single-piece housing joint is designed to accommodate cable insulation diameters ranging from 0.640 inches to 0.820 inches, ensuring a secure and insulated connection. It is compatible with copper conductors, supporting both stranded AWG #3 and solid AWG #2 conductor sizes. This product is a critical component for ensuring the integrity and safety of electrical distribution systems. Its robust construction and precise fit minimize the risk of electrical faults and enhance operational continuity. The single-piece housing simplifies installation, reducing labor time and potential for errors. This joint is suitable for various industrial and utility environments where dependable power transmission is paramount. The ABB Installation Products division is known for its commitment to quality and performance in electrical infrastructure. Ensure proper application and installation according to manufacturer guidelines for optimal performance and longevity. This joint is designed to meet the demanding requirements of medium voltage power distribution networks, providing a safe and efficient connection point for power cables.
  • 15kV voltage rating for medium voltage applications
  • Single-piece housing for simplified installation
  • Accommodates cable insulation diameters from 0.640" to 0.820"
  • Designed for copper conductors (AWG Stranded #3 / Solid #2)
  • ABB - Installation Products quality and reliability

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
#3 STR AWG , #2 SOL AWG
Connection
Compression
Insulation
Yes
Material
Copper
Material
EPDM Rubber
Number Of Conductors
2
Series
15PCJ1F2210
Series
Style 1
Size
14-3/8 inch long
Size
0.640-0.820 inch insulation diameter
Size
0.640 inch to 0.820 inch
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #3/Solid #2.

15PCJ1F1210

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #3/Solid #2.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.

15PCJ1F1250-1230

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

15PCJ1F1240

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.

15PCJ1F1230

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded #4/Solid #3.

15PCJ1F2200

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded #4/Solid #3.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1. luminum Conductor. Conductor Size AWG Stranded #3/Solid #2.

15PCJ1F1220-1210

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1. luminum Conductor. Conductor Size AWG Stranded #3/Solid #2.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.

15PCJ1F1220

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

15PCJ1F1270

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

Frequently Asked Questions

What cable insulation diameters does this joint accommodate?

This joint is designed to accommodate cable insulation diameters ranging from 0.640 inches to 0.820 inches.

What conductor types and sizes are compatible with this joint?

This joint is compatible with copper conductors, supporting both stranded AWG #3 and solid AWG #2 conductor sizes.

What is the voltage rating of this power cable joint?

The power cable joint has a voltage rating of 15kV.

What is the housing style of this ABB cable joint?

This ABB power cable joint features a single-piece housing.

How to Install the 15PCJ1F2210 Single Core Joint

This guide provides detailed instructions for the permanent installation of the 15PCJ1F2210 single core joint on extruded solid dielectric (XLPE or EPR) cables. It covers cable preparation, conductor splicing, and restoration of the screen and outer jacket.

Estimated time: 2h

Tools needed:

Wire strippers, Utility knife, Wire brush, Crimping tool, Cleaning cloths, Heat gun, Soldering iron (optional), Sanding paper or tool, Measuring tape

Supplies needed:

Joint Housing, PVC tape, Compression connector (copper or aluminum), Lubricant, Flat copper braid, Constant force springs (optional), Mastic tape, Heat shrink tubing, Cleaning solvent

  1. Initial Checks and Safety Precautions

    Ensure all apparatus is de-energized before beginning installation. Inspect all parts for damage, proper rating, and compatibility. Read the entire installation instructions and have all required tools at hand. Maintain cleanliness throughout the procedure.

  2. Prepare Cable Jackets and Metallic Shields

    Train cables into final position, leaving approximately 5mm between them. Store the heat shrink on either cable. Remove the jackets of both cables to the specified dimensions (e.g., 405mm for Size 1F-1G). Carefully remove the cable metallic tape screen for the specified distance (e.g., 125mm for Size 1F-1G) and secure the ends with PVC tape. Ensure PVC tape is on the copper tape and does not overlap onto the non-metallic screen.

  3. Remove Non-Metallic Screen and Prepare Insulation

    Carefully remove the cable non-metallic screen from both cables to the specified point (e.g., 45mm for Size 1F-1G). Bevel the edge of Cable 1. Cut the insulation to the conductor to dimension 'E' (e.g., 150mm for Size 1F-1G) from the end of both cables, but DO NOT remove the insulation. Install a PVC tape marker on Cable 2 to dimension 'B' (e.g., 155mm for Size 1F-1G) to locate the splice later. WARNING: DO NOT NICK, CUT OR DAMAGE THE INSULATION SURFACE OR CONDUCTOR STRANDS.

  4. Prepare Cable 1 and Store Joint Housing

    Apply one layer (half-lapped) of PVC tape over Cable 1's metallic screen, starting at the jacket and extending 10mm beyond the screen end. Install a different color PVC tape marker on Cable 1 to dimension 'B' (e.g., 155mm). Lubricate both cable entrances of the splice housing. Clean and lubricate Cable 1's insulation, non-metallic screen, and PVC taped metallic screen. Store the housing onto Cable 1 up to the jacket. WARNING: Cover all sharp metallic screen edges with PVC tape to prevent damage to the joint housing during storage. Do not store the splice housing on the exposed metallic tape shield.

  5. Remove Cable Insulation

    Remove cable insulation from both cables to dimension 'E' (e.g., 45mm for Size 1F-1G). DO NOT CUT OR NICK THE CABLE INSULATION OR CONDUCTOR.

  6. Install and Crimp Conductor Splice

    Wire brush the exposed conductors of both cables. Immediately insert both conductors fully into the conductor splice. Check the distance between insulations; if it exceeds the 'Before' dimension (e.g., 108mm for Size 1F-1G), do not proceed. Crimp the conductor splice according to the provided crimp chart. Remove any sharp protrusions or burrs and metal chips. Wipe off all excess inhibitor. Recheck the distance between cable insulations; if it exceeds the 'After' dimension (e.g., 102mm for Size 1F-1G), do not proceed.

  7. Clean and Lubricate Core Surfaces

    Clean the conductor, connector, and Cable 2 insulation surfaces with cleaning solvent and a clean cloth, always wiping towards the screen end. Lubricate cable insulation surfaces using the supplied lubricant, wiping towards the screen end to create a build-up or ramp of lubricant at the edge of the non-metallic screen. WARNING: REMOVE ALL CONTAMINANTS FROM THE SURFACE OF THE INSULATION.

  8. Position Joint Housing

    Slide the joint housing over the crimp connector into its final position. Measure the distance 'X' between the joint housing and the PVC tape marker on both sides; ensure these distances are equal. Remove the PVC tape applied in Step C to expose 25mm of copper tape.

  9. Restore Metallic Screen

    Wrap flat copper braid around each joint housing, extending the ends over the metallic tape screen for 20mm on each side. Attach each end of the copper braid to the metallic tape screen by soldering or using a constant force spring.

  10. Restore Outer Jacket

    Lightly sand the outer surface of the jacket of both cables for a distance of 130mm. Heat both sanded areas for approximately 15 seconds, being careful not to burn the cables. Wrap two layers of mastic tape at the edge of the jacket on both cables. Position the heat shrink from Cable 1 over the center of the assembly and shrink it, starting at the center and working towards the ends.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.