ABB Installation Products 15PCJ1F2270 15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…
UPC: 783786364855
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Cable Insulation Diameter Range: 0.640" to 0.820"
- Conductor Compatibility: Stranded 4/0 AWG or Solid 250 AWG copper
- Fully Shielded & Submersible Design for Direct Burial or Vault Installation
- Pin-and-Socket Interlock with 500 lbs. pull resistance for secure connections
- Manufacturer: ABB - Installation Products
Specifications
Application | For Direct Burial, Vault, Submersible and Other Severe Service Applications |
Color | Black |
Conductor Range | 4/0 STR AWG , 250 kcmil |
Connection | Compression |
Insulation | Yes |
Material | Copper |
Material | EPDM Rubber |
Number Of Conductors | 2 |
Series | 15PCJ1F |
Size | 14-3/8 inch long |
Size | 0.640 inch to 0.820 inch |
Special Features | Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable |
Standard | IEEE Standard 404 |
Type | Power Cable Joint |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

15PCJ1H2270
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
15PCJ1F2220
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded #2/Solid #1.
15PCJ1F2210
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded #3/Solid #2.
15PCJ1F1250-1230
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
15PCJ1F1240
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
15PCJ1F1210
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #3/Solid #2.
15PCJ1F1230
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
15PCJ1F2200
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded #4/Solid #3.Frequently Asked Questions
Can copper connectors be used with aluminum conductors?
No, copper compression connectors are suitable for splicing copper conductors to copper conductors only and should NOT be used on aluminum conductors.
What are Elastimold PCJ power cable joints used for?
They are used for straight splicing of two similar cables or transition splicing of different cable sizes, up to 1250 kcmil, in new or existing installations.
What voltage classes are available for PCJ joints?
Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.
What conductor materials are compatible with PCJ joints?
PCJ joints can be used with copper or aluminum conductors. Specific connectors are required for aluminum-to-aluminum, aluminum-to-copper, or copper-to-copper connections.
What is the maximum conductor size supported?
Elastimold PCJ power cable joints support a wide range of conductor sizes up to 1250 kcmil.
Can PCJ joints be used for different cable sizes?
Yes, Style 2 PCJ joints include separate cable adapters that allow for transition splicing between two different cable sizes.
What environments are suitable for PCJ joint installation?
PCJ power cable joints provide a permanent, fully shielded, fully submersible splice suitable for direct-burial, underground vault, and overhead applications.
What is the continuous current rating of PCJ joints?
The continuous current rating of PCJ power cable joints is equal to that of the cable rating.
What is the short-time current rating of PCJ joints?
The short-time current rating of PCJ power cable joints is equal to that of the cable rating, up to 35 kA.
What safety features do PCJ power cable joints have?
They feature a molded conductive shield for true dead-front construction and a grounding eye to connect a ground wire, placing the shield at ground potential.
How to Install a Single Core Cable Joint (15PCJ1F2270)
This guide provides step-by-step instructions for installing the 15PCJ1F2270 Single Core Joint, a permanent, fully screened, submersible joint for extruded solid dielectric cables. It covers cable preparation, connector installation, and final joint assembly.
Estimated time: 2h
Tools needed:
Cable strippers/knife, Measuring tape/ruler, Wire brush, Crimp tool (for conductor splice), Heat gun, Sandpaper, Soldering iron (optional, if not using constant force spring)
Supplies needed:
PVC tape (multiple colors), Cleaning solvent, Clean cloth, Lubricant (supplied with joint), Conductor splice (supplied with joint), Flat copper braid (supplied with joint), Constant force spring (optional), Mastic tape, Heat shrink tubing, HV insulated cap(s) or connector(s) (if applicable)
- De-energize and Inspect Components
DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products in the work area. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Ensure all apparatus is de-energized before beginning installation. Inspect all joint components for damage, correct rating, and compatibility with your cables. Have all required tools and supplies at hand, and maintain cleanliness throughout the procedure.
- Prepare Cable Jackets and Metallic Shields
Train both cables into their final position, leaving approximately 5mm between them. Store the heat shrink tubing on one of the cables. Remove the outer jackets of both cables to the specified dimensions (refer to Table A in the full documentation). Carefully remove the cable metallic tape screen for the specified distance, securing the ends with PVC tape. Ensure the PVC tape is only on the copper tape and does not overlap onto the non-metallic screen.
- Prepare Non-Metallic Screens and Insulation
Carefully remove the cable non-metallic screen from both cables to the specified point. WARNING: Do not nick, cut, or damage the insulation surface or conductor strands. Bevel the edge of Cable 1's insulation. Cut the insulation to the conductor to dimension 'E' from the end of both cables, but DO NOT remove the insulation. Install a PVC tape marker on Cable 2 to dimension 'B' to locate the splice later.
- Temporarily Store Joint Housing
Apply one layer of PVC tape (half-lapped) over the metallic screen of Cable 1, starting at the jacket and extending 10mm beyond the metallic screen end. Install a different color PVC tape marker on Cable 1 to dimension 'B'. Lubricate both cable entrances of the splice housing. Clean and lubricate the insulation, non-metallic screen, and PVC-taped portion of the metallic tape screen on Cable 1. Store the joint housing onto Cable 1, sliding it up to the jacket. WARNING: Cover any sharp edges of the metallic screen with PVC tape to prevent damage to the joint housing. Do not store the splice housing on the exposed metallic tape shield.
- Remove Cable Insulation
Remove the cable insulation from both cables to dimension 'E' (refer to Table D in the full documentation). WARNING: Do not cut or nick the cable insulation or conductor during this process.
- Install and Crimp Conductor Splice
Wire brush the exposed conductors of both cables. Immediately insert the conductors into the conductor splice, ensuring both are fully seated. Before crimping, check the distance between the insulations; if it exceeds the 'Before' dimension (Table E), review and redo the assembly. Crimp the conductor splice according to the provided crimp chart. Remove any sharp protrusions or burrs and ensure all metal chips or filings are removed from the splice joint assembly area. Wipe off any excess inhibitor. After crimping, re-check the distance between cable insulations; if it exceeds the 'After' dimension (Table E), review and redo the assembly.
- Clean and Lubricate Cable Core
WARNING: Remove all contaminants from the surface of the insulation. Clean the conductor, connector, and Cable 2 insulation surfaces using cleaning solvent and a clean cloth, always wiping towards the screen end. Lubricate the cable insulation surfaces with the supplied lubricant, wiping towards the screen end to create a build-up or ramp of lubricant at the edge of the non-metallic screen.
- Position Joint Housing
Slide the joint housing over the crimp connector into its final position. Measure the distance 'X' between the joint housing and the PVC tape markers on both sides; ensure this distance is equal. Remove the PVC tape applied in Step C to expose 25mm of the copper tape shield.
- Restore Metallic Screen
Wrap the flat copper braid around each joint housing, continuing the ends over the metallic tape screen for 20mm on each side. Attach each end of the copper braid to the metallic tape screen by either soldering or using a constant force spring.
- Restore Outer Jacket with Heat Shrink
Lightly sand the outer surface of the jacket of both cables for a distance of 130mm. Heat both sanded areas for approximately 15 seconds, being careful NOT to burn the cables. Wrap two layers of mastic tape at the edge of the jacket on both cables. Position the heat shrink tubing (stored in Step 2) over the center of the assembly and shrink it, starting at the center and working towards the ends.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.