Authorized ABB Distributor (Installation Products)
ABB - Installation Products 376LR-K-5250 - 35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

ABB Installation Products 376LR-K-5250 35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090…

UPC: 783786659333


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Minimum Qty: 10

Multiplier: 10

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 376LR-K-5250 Loadbreak Elbow Connector is a 35kV, 200 Amp rated device engineered for underground residential distribution (URD) systems and medium-voltage applications. This elbow connector features a bi-metal compression lug compatible with AWG compressed stranded 2/0, solid 3/0, or 67.43 mm² conductors, ensuring reliable electrical connections in utility and industrial power distribution networks. The integrated test point enables safe voltage verification without disconnecting the cable, reducing downtime during maintenance or troubleshooting. This connector accommodates cable insulation diameters from 1.090 inch to 1.310 inch, covering a range of common cable sizes used in 35kV Class, 200 Amp distribution systems. The fully shielded, fully submersible molded rubber housing is constructed with 100% peroxide-cured insulation and conductive EPDM materials, providing resistance to moisture ingress and corrosion in harsh environments. Key features include provisions for hot stick operation, enabling safe loadmaking and loadbreak operations on energized circuits up to 35kV. The connector also includes a provision for ground wire connection and a long bi-metal compression lug for secure, gas-tight connections. The 376LR-K-5250 meets ANSI/IEEE Standard 386, with ratings including: 21.1kV maximum phase-to-ground operating voltage, 36.6kV maximum phase-to-phase voltage, 150kV BIL impulse withstand, 50kV AC one-minute withstand, 103kV DC 15-minute withstand, 26kV AC corona extinction at 3p.C. sensitivity, 200 Amp continuous and loadbreak rating, and 10kA symmetrical 10-cycle momentary and fault close rating. Ideal for utility crews and field technicians, this connector provides a convenient method to connect or disconnect systems in medium-voltage distribution networks, ensuring reliable performance and extended service life in demanding applications.
  • 35kV, 200 Amp rated loadbreak elbow connector
  • Bi-metal compression lug for AWG 2/0, solid 3/0, or 67.43 mm² conductors
  • Integrated test point for safe voltage verification without disconnection
  • Fully shielded, submersible molded rubber housing with peroxide-cured EPDM
  • Hot stick operation provision for safe loadmaking/loadbreak on energized circuits

Specifications

Amperage Rating
200 A
Application
35 kv, 200 Amp
Color
Black
Conductor Range
2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG
Conductor Size
AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43
Connection
Push-In
Connection Type
Loadbreak Elbow Connector with Test Point
Connection Type
Compression Lug
Current Rating
200 A
Environmental Conditions
Fully Submersible
Insulation
True
Ip Rating
Fully Submersible
Material
Rubber, EPDM, Bi-Metal, Peroxide-cured Insulation
Material
Bi-Metal Compression Lug
Material
Housing - EPDM-Rubber
Series
376LR
Size
Cable Insulation Diameter 1.090 inch to 1.310 inch
Special Features
35kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Non-Corrosive Capacitive Voltage Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector with Test Point
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
3.0800 L
Package Weight (Metric)
1.3970 kg
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

375LR-J-5250

200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

376LR-H-5250

35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

376LR-J-5250

200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
200 Amp, 15kV, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. Includes 02800X Bi-Metal Contact.

167LRT-F5210

200 Amp, 15kV, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. Includes 02800X Bi-Metal Contact.
15kV 200 Amp, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

167LRT-G5240

15kV 200 Amp, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
200 Amp, 25kV, Loadbreak Replacement Elbow Connector without Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

273RLR-J-5240

200 Amp, 25kV, Loadbreak Replacement Elbow Connector without Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.640 inch to 0.820 inch. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

167RLR-F-5220

15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.640 inch to 0.820 inch. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

167RLR-H-5270

15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

Frequently Asked Questions

What conductor sizes does this connector support?

The bi-metal compression lug supports AWG compressed stranded 2/0, solid 3/0, or 67.43 mm² conductors.

Does this connector include a test point?

Yes, the connector features an integrated test point for safe voltage verification.

What is the cable insulation diameter range?

The connector accommodates cable insulation diameters from 1.090 inch to 1.310 inch.

What is the maximum operating voltage for this connector?

The connector is rated for a maximum operating voltage of 35kV.

Is this connector suitable for loadbreak operations?

Yes, the 376LR-K-5250 is designed for loadbreak operations, allowing safe switching of energized circuits.

How to Install 375LR/376LR Loadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of Elastimold 375LR and 376LR Loadbreak Elbow Connectors on UD cable. Ensure all apparatus are de-energized before beginning installation.

Estimated time: 1h 30m

Tools needed:

Probe wrench, Crimp tool, Wire brush, Cable knife or Wire strippers, Hotstick

Supplies needed:

Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied with kit), No. 14 AWG / 2.5mm copper wire, Appropriate grounding connector

  1. Perform Pre-Installation Checks

    Before starting, verify the package contents are complete and undamaged. Check all components for proper fit with the cable and mating products. Thread the probe into the compression lug to ensure it turns freely without resistance; replace any damaged components. Read all instructions thoroughly and gather all required tools, maintaining cleanliness throughout the procedure. Ensure all apparatus are de-energized before proceeding with installation.

  2. Prepare the Cable

    Train the cable to ease operation, ensuring a minimum of 20 inches extends beyond the end of the cable pad mount transformer. Cut the excess cable squarely at the center line of the bushing. Unwrap and bind the concentric neutral wires 8-1/2 inches back from the cable end. Carefully remove the shield and insulation from the cable end, cutting squarely without nicking the conductor. Wire brush bare aluminum conductors and immediately install the compression lug, rotating to spread the inhibitor. Align the lug's threaded hole with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Wipe off any excessive inhibitor. Remove the insulation shield and bevel the insulation end a maximum of 1/8 inch. Thoroughly clean the insulation to remove all traces of conductive residue.

  3. Assemble the Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off any excess grease. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the probe wrench until the wrench bends, indicating proper torque.

  4. Connect the Concentric Neutral

    Insert one end of a separate No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the elbow. Twist it tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Ensure adequate slack in the wires to allow for elbow operation.

  5. Connect Elbow to Bushing Plug

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant ONLY if the transformer and elbow are known to be de-energized. Do not operate by hand; use a full insulated 'hotstick' type live-line tool as per the operating instructions for loadmake operation. Ensure the area is clear of obstructions and contaminants before operation.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.