ABB Installation Products 273RLR-J-5240 200 Amp, 25kV, Loadbreak Replacement Elbow Connector without Test Point, Repair Elbow…
UPC: 783786660230
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 200 Amp, 25kV loadbreak replacement elbow connector
- Extended length contact and housing (8-7/8 inches net gain)
- Cable insulation diameter range: 0.980" to 1.180"
- Includes 00400X long Bi-Metal Contact for enhanced conductivity
Specifications
Amperage Rating | 200 A |
Application | Designed for connecting to and operating 25kV Class, 125kV BIL apparatus |
Color | Black |
Conductor Range | 1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG |
Environmental Conditions | Fully Submersible |
Insulation | True |
Material | Housing - EPDM-Rubber |
Size | Cable Insulation Diameter 0.980 inch to 1.180 inch |
Special Features | Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured insulation, insert and jacket. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes. Extended Length Housing and Compression Lug - plus 10-1/2 inch (266.7mm) |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Replacement Elbow Connector |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 0.0200 L |
Package Weight (Metric) | 0.0090 kg |

K655LR-H0240
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed Stranded 1/0 or Compacted Solid 2/0.
167RLR-F-5220
15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.640 inch to 0.820 inch. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
167RLR-H-5270
15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
K151SR-B2230
15/25kV 200 Amp, Deadbreak Straight Receptacle (All Copper Lug), Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
376LR-K-5270
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
K151SR-A0230
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1 or Solid 1/0 or mmSquared 42.41.
376LR-J-5240
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
376LR-J-5230
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.Frequently Asked Questions
What is the current rating of these connectors?
These are 200 A loadbreak repair and replacement elbow connectors.
What industry standards does this product meet?
The product is IEEE 386 compliant, ANSI certified, and Rural Utilities Service (RUS) accepted.
How much extra length does the replacement elbow provide?
The replacement elbow provides a net gain of 8 7/8 inches in length due to its extended-length contact and elbow housing.
What is the voltage rating of the 273RLR elbow?
The 273RLR replacement elbow connector is rated for a 25 kV voltage class.
What is the current rating of these connectors?
These are 200 A loadbreak repair and replacement elbow connectors.
What industry standards does this product meet?
The product is IEEE 386 compliant, ANSI certified, and Rural Utilities Service (RUS) accepted.
How much extra length does the replacement elbow provide?
The replacement elbow provides a net gain of 8 7/8 inches in length due to its extended-length contact and elbow housing.
What is the voltage rating of the 273RLR elbow?
The 273RLR replacement elbow connector is rated for a 25 kV voltage class.
What industry standards does this product meet?
The product is IEEE 386 compliant, ANSI certified, and Rural Utilities Service (RUS) accepted.
What is the voltage rating of the 273RLR elbow?
The 273RLR replacement elbow connector is rated for a 25 kV voltage class.
How to Install the Elastimold 273RLR/274RLR Loadbreak Replacement Elbow Connector
This guide provides step-by-step instructions for the safe installation and initial setup of the Elastimold 273RLR (without Test Point) and 274RLR (with Test Point) Loadbreak Replacement Elbow Connectors, converting livefront terminations to deadfront for UD cable.
Estimated time: 1h 30m
Tools needed:
Probe Wrench, Wire brush, Wrench, Hotstick, Suitable sensing device (for capacitive test points, 274RLR only)
Supplies needed:
Replacement Elbow Connector Housing, Compression Lug, Probe, Lubricant (Do Not Substitute), Hose Clamp, Separate copper wire (No. 14 AWG / 2.5mm or equivalent), Appropriate ground connector, Silicone grease
- Prepare for Installation and Ensure Safety
DANGER: All apparatus must be de-energized during installation or removal of part(s). Check the contents of the package to ensure they are complete and undamaged. Verify all components for proper fit with the cable and/or mating products. Check the probe threads by threading the probe into the compression lug; if resistance is encountered prior to full assembly, replace the damaged component. Have all required tools at hand and maintain cleanliness throughout the procedure.
- Remove Existing Livefront Termination
Remove the rubber cap from the terminator. Cut off the connector at the top of the terminator. Disconnect the ground lead from the base of the terminator. Finally, remove the terminator housing from the cable.
- Prepare the Cable
Train the cables to be straight and in-line with the bushing centerline. Cut the cable to measure 10-1/2 inches from the bushing centerline. Check the distance from the end of the cut cable to the insulation shield; if it measures less than 6-1/2 inches, continue. If greater, consult your nearest ELASTIMOLD representative. Remove cable insulation 1-3/8 inches from the end of the cable, cutting squarely. DO NOT NICK THE CONDUCTOR.
- Install the Compression Lug
Wire brush the bare aluminum conductor and immediately install the compression lug, rotating it to spread the inhibitor. Position the compression lug so the contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart packaged with the compression lug, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe excessive inhibitor from the outside of the lug and cable.
- Assemble the Elbow Connector
Lubricate the cable insulation and inside the elbow housing with the supplied lubricant. DO NOT SUBSTITUTE, as other lubricants may be harmful. Keep insulation clean of dirt and grime, and do not introduce excess grease into the gap between the lug and the insulation. Slide the elbow connector onto the cable with a back and forth twisting motion, then wipe off all excess grease. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, taking care not to cross-thread; the probe must turn freely for approximately four turns before becoming snug. Tighten the probe with a wrench until the wrench bends.
- Connect the Concentric Neutral
Using a separate copper wire (No. 14 AWG / 2.5mm or equivalent), insert one end through the grounding eye on the elbow and twist it tight, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation. Add the supplied hose clamp as shown and tighten it snugly, but do not overtighten.
- Connect Elbow to Bushing Plug
Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. LUBRICATE ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED. Remove the insulated cap from the bushing by attaching a hotstick tool to the insulated cap pulling eye. Securely fasten a hotstick to the loadbreak connector pulling eye. Withdraw the elbow from the apparatus parking stand with a fast, straight, firm motion. Place the elbow connector receptacle area over the bushing plug, inserting the elbow male contact (arc follower portion) into the bushing until the first slight resistance is felt. Immediately push the elbow home with a fast, firm, straight motion to engage the internal lock on the elbow and bushing interface. Apply sufficient force to ensure the internal lock engages.
- Perform Voltage Test (274RLR Only)
If using a 274RLR connector, perform a voltage test. Remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly in line with the test point assembly. WARNING: The voltage test point is a capacitance device; it is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device made for use with separable connectors manufactured with capacitive test points to determine if the cable is energized. Contamination, moisture, dirt, etc., around the test point or use of the wrong measuring equipment can provide a false 'no voltage' indication on an energized elbow. To prevent serious or fatal injury, treat the elbow as energized until the 'no voltage' test point indication is confirmed by other means. After voltage detection, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.