ABB - Installation Products 167RLR-F-5220 - 15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.640 inch to 0.820 inch. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

ABB Installation Products 167RLR-F-5220 15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length…

UPC: 783786666188


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 167RLR-F-5220 Loadbreak Replacement Elbow Connector is a 15kV, 200 Amp rated elbow designed for medium-voltage cable repair and replacement in underground distribution systems. The bi-metal contact ensures reliable electrical continuity and corrosion resistance, while the extended housing accommodates cable insulation diameters from 0.640 inch to 0.820 inch. Designed for compressed stranded #2 or solid #1 conductors (33.62 mm²), this elbow is ideal for applications requiring loadbreak operations, such as utility substations, switchgear, and pad-mounted transformers. The 200 Amp rating supports high-current circuits, and the loadbreak design allows for safe connection and disconnection under load conditions. Compatible with industry-standard 15kV class equipment, this replacement elbow minimizes downtime during maintenance or fault repairs. Key features include dead-front construction for insulation and shielding, eliminating exposure to live components. The specially formulated, non-rigid ethylene propylene diene monomer (EPDM) rubber construction allows for expansion and controlled gas release. An optional built-in capacitive test point enables voltage testing without disconnecting the circuit. The robust stainless steel pulling eye ensures safer, more durable hot-stick control. This elbow saves time and money by eliminating the need for splicing or installing new cable in retrofit installations, addressing varying bushing heights and incorrect cable terminations. IEEE 386 compliant and ANSI certified, the 167RLR-F-5220 is assembled in Albuquerque, New Mexico, USA, and meets Rural Utilities Service (RUS) acceptance criteria.
  • 15kV, 200 Amp rated loadbreak replacement elbow connector
  • Bi-metal contact ensures reliable electrical continuity and corrosion resistance
  • Accommodates cable insulation diameters from 0.640" to 0.820"
  • Designed for compressed stranded #2 or solid #1 conductors (33.62 mm²)
  • Optional built-in capacitive test point for voltage testing
  • Dead-front construction insulates and shields live components
  • IEEE 386 compliant and ANSI certified
  • Rural Utilities Service (RUS) accepted
  • Assembled in Albuquerque, New Mexico, USA

Specifications

Amperage Rating
200 A
Application
Designed for connecting to and operating 15kV Class, 95kV BIL apparatus
Color
Black
Conductor Range
#2 STR/COMPR AWG , #1 SOL/COMPT AWG
Conductor Size
AWG Compressed Stranded #2/Solid #1/mmSquared 33.62
Connection Type
Loadbreak
Current Rating
200 A
Environmental Conditions
Fully Submersible
Insulation
True
Material
Bi-Metal
Material
Housing - EPDM-Rubber
Series
167RLR
Size
Extended length (8-7/8 inches)
Size
Cable Insulation Diameter 0.640 inch to 0.820 inch
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured insulation, insert and jacket. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes. Extended length housing and compression lug plus 10-1/2 inch (266.7mm)
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Replacement Elbow Connector
Voltage Rating
15 kV
Voltage Rating
15kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
4.2800 L
Package Weight (Metric)
1.9410 kg
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, #2 Stranded Wire Size, Bi-Metal Compression Lug.

262LR-D5220

25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, #2 Stranded Wire Size, Bi-Metal Compression Lug.
POWER TERMINALS TYPE 3 RENTAL

45030034

POWER TERMINALS TYPE 3 RENTAL
15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

167RLR-H-5270

15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
15/25kV 200 Amp, Deadbreak Straight Receptacle (All Copper Lug), Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

K151SR-B2230

15/25kV 200 Amp, Deadbreak Straight Receptacle (All Copper Lug), Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

376LR-K-5270

35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1 or Solid 1/0 or mmSquared 42.41.

K151SR-A0230

200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1 or Solid 1/0 or mmSquared 42.41.
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

376LR-J-5240

35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

376LR-J-5230

35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

Frequently Asked Questions

What is the test point cap catalog number?

The test point cap catalog number for elbows with a test point is 156-7.

Where are Elastimold elbows manufactured?

Elastimold 200 A repair and replacement elbows are designed, molded, and tested in Albuquerque, NM, USA.

Are these elbow connectors certified?

Yes, these connectors are IEEE 386 compliant, ANSI certified, and Rural Utilities Service (RUS) accepted.

What material are the elbows constructed from?

The elbows are constructed from specially formulated, non-rigid ethylene propylene diene monomer (EPDM) rubber.

How much length does the replacement elbow add?

The replacement elbow extends its housing and compression lug length to 8 7/8 inches over the standard elbow.

How much length does the repair elbow add?

The repair elbow features an extended housing and compression lug length that is 3 1/4 inches longer than the standard elbow.

What voltage classes do these connectors support?

The ABB Elastimold loadbreak repair and replacement elbows are available for 15 kV and 25 kV voltage classes.

What is the current rating of the elbow connectors?

The elbow connectors are rated for 200 A loadbreak applications.

How much longer are the repair and replacement elbows?

The repair elbow is 3 1/4 inches longer than a standard elbow, and the replacement elbow is 8 7/8 inches longer.

What is the current rating of these connectors?

The current rating for these loadbreak repair and replacement elbow connectors is 200 A.

How to Install 167RLR/168RLR Loadbreak Replacement Elbow Connectors

This guide provides detailed instructions for the safe installation and initial connection of Elastimold 167RLR and 168RLR Loadbreak Replacement Elbow Connectors, converting livefront terminations to deadfront for UD cables.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Crimping tool, Wire brush, Hotstick

Supplies needed:

Replacement Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant (Do Not Substitute), Hose Clamp, Separate copper wire (No. 14 AWG / 2.5mm) or equivalent, Appropriate connector for ground

  1. Perform Initial Checks and Ensure Safety

    DANGER: All apparatus must be de-energized during installation or removal of part(s). This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Check the contents of the package to ensure they are complete and undamaged. Verify all components for proper fit with the cable and/or mating products. Check threads by threading the probe into the compression lug; if resistance is encountered, check for damage and replace the component. Have all required tools at hand and maintain cleanliness throughout the procedure.

  2. Remove Existing Livefront Termination

    DANGER: All apparatus must be de-energized during installation or removal of part(s). Remove the rubber cap from the terminator. Cut off the connector at the top of the terminator. Disconnect the ground lead from the base of the terminator. Finally, remove the terminator housing from the cable.

  3. Prepare the Cable

    Train the cable to be straight and in-line with the bushing centerline. Cut the cable to measure 10-1/2 inches from the bushing centerline. Check the distance from the end of the cut cable to the insulation shield. If the insulation shield measures less than 6-1/2 inches, proceed to the next step (insulation shield will be cut in Step 4). If it is greater than 6-1/2 inches, consult your nearest ELASTIMOLD representative. Remove 1-3/8 inches of cable insulation from the end of the cable, cutting squarely. DO NOT NICK THE CONDUCTOR.

  4. Install the Compression Lug

    Wire brush the bare aluminum conductor and immediately install the compression lug. Rotate the lug to spread the inhibitor. Position the compression lug so the contact threaded hole aligns with the bushing bore. Refer to the crimp chart packaged with the compression lug for recommended crimp information. Start crimping at the crimp line mark, rotating 180 degrees for each successive crimp. Carefully wipe excessive inhibitor from the outside of the lug and cable.

  5. Assemble the Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the lubricant supplied. DO NOT SUBSTITUTE other lubricants, as they may be harmful. Keep the insulation clean of dirt and grime. Do not use excess grease and do not introduce any grease into the gap between the lug and the insulation. Slide the elbow connector onto the cable with a back and forth twisting motion. Wipe off all excess grease. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, taking care not to cross-thread. The probe must turn freely for approximately four turns before becoming snug. Tighten with the wrench until the wrench bends.

  6. Connect the Concentric Neutral

    Using a separate copper wire (No. 14 AWG / 2.5mm) or equivalent, insert one end through the grounding eye on the elbow. Twist it tight, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation. Add the hose clamp as shown in the documentation and tighten snugly. Do not overtighten.

  7. Connect the Elbow to the Bushing Plug

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. LUBRICATE ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED. DO NOT OPERATE BY HAND. Securely fasten a hotstick to the loadbreak connector pulling eye. Place the elbow connector receptacle area over the bushing plug, inserting the elbow male contact (arc follower portion) into the bushing until the first slight resistance is felt. Immediately push the elbow home with a fast, firm, straight motion to engage the internal lock on the elbow and bushing interface. Apply sufficient force to engage the internal lock.

  8. Perform Voltage Test (168RLR Only)

    For 168RLR connectors, remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly in line. WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Follow the manufacturer’s directions for the meter used. Test with a suitable sensing device, made for use with separable connectors manufactured with capacitive test points, to determine if the cable is energized. Contamination, moisture, dirt, or use of the wrong measuring equipment can provide a false 'no voltage' indication. Treat the elbow as energized until the 'no voltage' test point indication is confirmed by other means. After voltage detection, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.