ABB - Installation Products 167LRT-G5240 - 15kV 200 Amp, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

ABB Installation Products 167LRT-G5240 15kV 200 Amp, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.640 inch to…

UPC: 783786660650


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB 167LRT-G5240 is a 15kV, 200 Amp loadbreak bolted elbow connector designed for reliable cable termination. It accommodates cable insulation diameters ranging from 0.640 inches to 0.820 inches. The integrated bi-metal compression lug ensures secure and durable connections for conductors sized from 1/0 AWG compressed stranded to 2/0 AWG solid, with a corresponding mm² size of 53.49. This component is essential for creating safe and efficient connections in medium-voltage electrical distribution systems. The bolted design simplifies installation and maintenance, while the loadbreak capability allows for de-energization under load conditions, enhancing operational safety. Manufactured by ABB - Installation Products, this elbow connector meets stringent industry requirements for medium-voltage applications. Its robust construction and precise specifications make it suitable for utility, industrial, and commercial power distribution networks where dependable performance is critical. The UNSPSC code for this product is 39121421.
  • 15kV voltage rating
  • 200 Amp current rating
  • Accommodates cable insulation diameter: 0.640" - 0.820"
  • Bi-metal compression lug for conductor sizes 1/0 AWG (stranded) to 2/0 AWG (solid)
  • Loadbreak bolted elbow with tap

Specifications

Amperage Rating
200 A
Application
15kV, 200 Amps
Color
Black
Conductor Range
1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG
Connection Type
Bolted Elbow with Tap
Current Rating
200 A
Environmental Conditions
Fully Submersible
Insulation
True
Material
Bi-Metal
Material
Housing - EPDM-Rubber
Series
167LRT
Size
Cable Insulation Diameter 0.640 inch to 0.820 inch
Size
Cable Insulation Diameter 0.760 inch to 0.950 inch
Special Features
Includes 02800X Bi-Metal Contact
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Bolted Elbow with Tap
Voltage Rating
15 kV
Voltage Rating
15kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
3.0000 L
Package Weight (Metric)
1.3610 kg
200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

168ELR88110-5240

200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
POWER TERMINALS TYPE 3 RENTAL

45030034

POWER TERMINALS TYPE 3 RENTAL
200 Amp, 25kV, Loadbreak Replacement Elbow Connector without Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

273RLR-J-5240

200 Amp, 25kV, Loadbreak Replacement Elbow Connector without Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.640 inch to 0.820 inch. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

167RLR-F-5220

15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.640 inch to 0.820 inch. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

167RLR-H-5270

15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
15/25kV 200 Amp, Deadbreak Straight Receptacle (All Copper Lug), Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

K151SR-B2230

15/25kV 200 Amp, Deadbreak Straight Receptacle (All Copper Lug), Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

376LR-K-5270

35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1 or Solid 1/0 or mmSquared 42.41.

K151SR-A0230

200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1 or Solid 1/0 or mmSquared 42.41.

Frequently Asked Questions

What items are included in the 167LRT kit?

The kit includes the elbow connector housing, a compression lug, a stud extender, lubricant, an installation tool, a wrench, installation instructions, and a crimp chart.

What standards does the 167LRT conform to?

The 167LRT conforms to ANSI Std. 386, Figure 5, and mates with bushing wells conforming to ANSI Std. 386, Figure 3.

What are the primary applications of the 167LRT?

The 167LRT is designed for connecting to and operating 15kV-class, 95BIL distribution apparatus. It provides a loadbreak operating interface for phasing, grounding, testing, or arrester protection.

What is the fault close rating?

The momentary and fault close rating is 10kA Symmetrical for 10 cycles.

What are the AC and DC withstand voltages?

The 167LRT has a 34kV AC one-minute withstand and a 53kV DC 15-minute withstand rating.

What is the impulse withstand rating?

The impulse withstand (BIL) rating is 95kV (1.2 x 50 microsecond wave).

What is the maximum operating voltage?

The maximum phase-to-ground operating voltage is 8.3 kV, and the maximum phase-to-phase voltage is 14.4 kV.

What should cover the tap point when not in use?

The loadbreak-rated tap point must be covered with an insulated cap when not in use.

What are the current and voltage ratings?

The 167LRT is rated as a 200 AMP, 15kV deadbreak connector, with a 15kV, 200 Amp loadbreak tap point.

What is the 167LRT product type?

The 167LRT is an Elastimold Bolted Elbow with Tap, functioning as a loadbreak elbow connector with a loadbreak tap. It is rated as a 200 AMP, 15kV deadbreak connector.

How to Install the 167LRT Loadbreak Bushing Tap

This guide provides step-by-step instructions for the safe and proper installation of the 167LRT Loadbreak Bushing Tap, including cable preparation, assembly, and grounding.

Estimated time: 1h

Tools needed:

Wrenches, Installation Tool, Crimp tool, Wire brush

Supplies needed:

Compression Lug, Socket Contact, Lubricant (Do Not Substitute), Well Contact, No. 14 AWG (2.5mm) copper wire or equivalent, Appropriate connector (for grounding), Insulated cap or elbow (for mating product)

  1. Perform Initial Safety and Component Checks

    DANGER: Ensure all apparatus is de-energized before beginning installation. This product should only be installed by competent personnel trained in high voltage electrical equipment. Inspect all package contents for completeness and damage. Verify all components are compatible with the cable and mating products. Read these instructions fully before starting and have all required tools ready, maintaining cleanliness throughout the procedure.

  2. Prepare and Train the Cable

    Train the UD cable as shown in the diagram to ease future operation, ensuring at least 20 inches beyond the end of the cable pad mount transformer. Cut the excess cable squarely at the center line of the bushing. Unwrap and bind the concentric neutral wires 8-1/2 inches back from the cable end. Remove the semi-con shield and insulation from the cable end, cutting squarely without nicking the conductor. Wire brush bare aluminum conductors and immediately install the compression lug, rotating to spread inhibitor. Position the lug so its threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe excessive inhibitor from the lug and cable. Bevel the insulation end a maximum of 1/8 inch and thoroughly clean the insulation to remove all traces of conductive residue.

  3. Assemble the Bushing Well Contact

    Thread the well contact onto the bushing well stud by hand, taking care not to cross-thread. Use the supplied wrench to tighten the well contact until the wrench bends, signifying proper torque.

  4. Assemble the Bushing Tap Housing to the Cable

    Remove the protective cap from the bushing tap and retrieve the socket contact stored inside the housing. Lubricate the cable insulation and the inside of the bushing housing with the supplied lubricant; DO NOT SUBSTITUTE. Other lubricants may be harmful. Keep insulation clean and avoid introducing excess grease into the gap between the lug and insulation. Slide the bushing tap onto the cable using a back-and-forth twisting motion, then wipe off all excess grease. Align the bushing with the compression lug hole and assemble the socket contact into the bushing tap, ensuring the socket contact stud passes through the lug hole.

  5. Mount and Secure the Bushing Tap

    Inspect the apparatus bushing well to ensure it is dry and free from contaminants. Lubricate the bushing well interface area of the bushing tap with the supplied or ELASTIMOLD approved lubricant. Place the lubricated bushing tap into the apparatus bushing well. Insert the installation tool into the bore of the bushing tap until it is fully seated. Insert a wrench through the wrench hole of the tool and turn clockwise until the wrench bends, indicating the proper assembly torque has been reached. Remove the wrench and installation tool from the bushing tap, ensuring the tool is clean before insertion.

  6. Connect the Concentric Neutral

    Insert one end of a No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the bushing tap. Twist the wire tight, taking care not to damage the eye. Twist the neutral wires together and connect them to ground using an appropriate connector.

  7. Lubricate Interface and Install Mating Product

    Thoroughly wipe the bushing tap interface clean of any contaminants. Apply a light, uniform coat of the supplied lubricant, working it thoroughly into the surface. CAUTION: Excess lubricant may prevent a loadbreak elbow from being fully seated in the 'locked on' position. Install the mating products (e.g., loadbreak elbow, insulated cap, or grounding elbow) to the bushing tap following their specific instructions. If a mating product is not immediately installed, replace the shipping cap. Do not energize or submerge the apparatus with only the shipping cap, as it is not insulated or watertight.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.