ABB Installation Products 167RLR-H-5270 15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length…
UPC: 783786663675
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Extended housing and compression lug length for 8-7/8 inches of additional clearance
- Bi-metal contact for durable electrical conductivity
- Supports cable insulation diameters from 0.850 to 1.050 inches
- Accommodates compressed stranded AWG 4/0 or solid AWG 250 conductors (126.67 mm²)
- Optional built-in capacitive test point for safe voltage testing
- Dead-front construction for enhanced safety during installation and maintenance
- Non-stick EPDM rubber construction for easier removal and controlled gas release
- Robust stainless steel pulling eye for safer hot-stick control
- IEEE 386 compliant and ANSI certified for reliability
Specifications
Amperage Rating | 200 A |
Application | Designed for connecting to and operating 15kV Class, 95kV BIL apparatus |
Color | Black |
Conductor Range | 4/0 STR/COMPR AWG , 250 kcmil |
Conductor Size | AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67 |
Connection Type | Compression Lug |
Current Rating | 200A |
Current Rating | 200 A |
Environmental Conditions | Fully Submersible |
Insulation | True |
Material | Bi-Metal |
Material | EPDM Rubber, Stainless Steel, Bi-Metal |
Material | Housing - EPDM-Rubber |
Mounting Type | Dead-front construction |
Series | 167RLR |
Size | Extended Length (8-7/8 inches net gain) |
Size | Cable Insulation Diameter 0.850 inch to 1.050 inch |
Special Features | Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured insulation, insert and jacket. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes. Extended length housing and compression lug plus 10-1/2 inch (266.7mm) |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Replacement Elbow Connector |
Voltage Rating | 15 kV |
Voltage Rating | 15kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 4.2800 L |
Package Weight (Metric) | 1.9410 kg |

167LRT-F5270
200 Amp, 15kV, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. Includes 02800X Bi-Metal Contact.
K151SR-B2230
15/25kV 200 Amp, Deadbreak Straight Receptacle (All Copper Lug), Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
376LR-K-5270
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
K151SR-A0230
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1 or Solid 1/0 or mmSquared 42.41.
376LR-J-5240
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
376LR-J-5230
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
168ELR-7495-5260
15kV 200 Amp, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Cable Insulation .740-.950 inches, Bi-Metal Contact. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.Frequently Asked Questions
Where are Elastimold elbows manufactured?
Elastimold 200 A repair and replacement elbows are designed, molded, and tested in Albuquerque, NM, USA.
What is the test point cap catalog number?
The test point cap catalog number for elbows with a test point is 156-7.
What is the current rating of the elbow connectors?
The elbow connectors are rated for 200 A loadbreak applications.
What voltage classes do these connectors support?
The ABB Elastimold loadbreak repair and replacement elbows are available for 15 kV and 25 kV voltage classes.
How much length does the repair elbow add?
The repair elbow features an extended housing and compression lug length that is 3 1/4 inches longer than the standard elbow.
How much length does the replacement elbow add?
The replacement elbow extends its housing and compression lug length to 8 7/8 inches over the standard elbow.
What material are the elbows constructed from?
The elbows are constructed from specially formulated, non-rigid ethylene propylene diene monomer (EPDM) rubber.
Are these elbow connectors certified?
Yes, these connectors are IEEE 386 compliant, ANSI certified, and Rural Utilities Service (RUS) accepted.
What cable insulation diameter does the 167RLR-H elbow support?
The 15kV replacement elbow (167RLR) with the 'H' symbol supports cable insulation diameters from 0.850 to 1.050 inches.
What is the primary use of these elbow connectors?
They are used to transition from live-front to dead-front equipment, especially when replacing switchgear and transformers, without needing to splice or pull new cable.
How to Install and Operate Elastimold 167RLR/168RLR Loadbreak Replacement Elbow Connectors
This guide provides step-by-step instructions for the safe installation, wiring, and initial operation of Elastimold 167RLR and 168RLR loadbreak replacement elbow connectors, converting livefront terminations to deadfront for UD cable.
Estimated time: 1h 30m
Tools needed:
Probe wrench, Wire brush, Crimping tool, Hotstick (insulated live-line tool), Suitable sensing device for capacitive test points (for 168RLR)
Supplies needed:
Replacement Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied), Hose Clamp, Copper wire (No. 14 AWG / 2.5mm), Appropriate connector (for neutral wires), Silicone grease (for 168RLR test point cap)
- De-energize and Remove Livefront Terminator
DANGER: Ensure all apparatus is de-energized before beginning installation or removal. Remove the rubber cap from the existing terminator. Cut off the connector at the top of the terminator. Disconnect the ground lead from the base of the terminator, then remove the entire terminator housing from the cable.
- Prepare the Cable
Train the cable to be straight and in-line with the bushing centerline. Measure and cut the cable to 10-1/2 inches (26.7 cm) from the bushing centerline. Remove 1-3/8 inches (3.5 cm) of cable insulation from the end, ensuring the cut is square and the conductor is not nicked. Verify the insulation shield measures less than 6-1/2 inches (16.5 cm) from the end of the cut cable.
- Install the Compression Lug
Wire brush the bare aluminum conductor thoroughly. Immediately install the compression lug onto the conductor, rotating it to spread the inhibitor. Position the lug so its contact threaded hole aligns with the bushing bore. Crimp the lug according to the manufacturer's chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe off any excessive inhibitor from the lug and cable.
- Assemble the Elbow Housing
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off any excess grease. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug, then tighten it with the probe wrench until the wrench bends.
- Connect the Concentric Neutral
Insert one end of a separate No. 14 AWG (2.5mm) copper wire through the grounding eye on the elbow and twist it tight, being careful not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, providing adequate slack for elbow operation. Add the supplied hose clamp as shown and tighten it snugly, but do not overtighten.
- Connect Elbow to Bushing Plug (De-energized)
Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. IMPORTANT: Only lubricate if the transformer and elbow are confirmed to be de-energized. Do not operate by hand; use a hotstick for all connections and disconnections.
- Perform Loadmake Operation (Energized)
DANGER: Use a full insulated "hotstick" type live-line tool for all energized operations. Ensure the area is clear of obstructions. Remove the insulated cap from the bushing using the hotstick. Securely fasten the hotstick to the loadbreak connector pulling eye. Withdraw the elbow from the apparatus parking stand with a fast, straight, firm motion. Place the elbow connector receptacle over the bushing plug, inserting the male contact until slight resistance is felt (contacts are approximately 2 inches apart). Immediately push the elbow home with a fast, firm, straight motion to engage the internal lock. Apply sufficient force to ensure the internal lock engages.
- Perform Loadbreak Operation (Energized)
DANGER: Use a full insulated "hotstick" type live-line tool. Place the desired accessory device on the apparatus parking stand. Firmly tighten a hotstick to the loadbreak connector pulling eye. Slightly rotate the connector clockwise to break surface friction before disconnection. Withdraw the connector from the bushing with a fast, firm, straight motion. Place the connector on the appropriate accessory device.
- Test Voltage (168RLR Only)
If using a 168RLR connector, remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device; do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points to determine if the cable is energized. After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point. Treat the elbow as energized until the "no voltage" indication is confirmed by other means.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.