ABB - Installation Products 167LRT-F5210 - 200 Amp, 15kV, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. Includes 02800X Bi-Metal Contact.

ABB Installation Products 167LRT-F5210 200 Amp, 15kV, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.640 inch to…

UPC: 783786661077


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 167LRT-F5210 Loadbreak Bolted Elbow with Tap is a 200 Amp, 15kV deadbreak connector engineered for medium voltage power distribution systems. This fully-shielded, fully submersible molded rubber elbow connector delivers reliable and safe switching operations in industrial and utility environments. The 167LRT-F5210 is rated for 15kV class systems with a maximum phase-to-ground operating voltage of 8.3kV and phase-to-phase voltage of 14.4kV. It meets ANSI/IEEE Standard 386 requirements, including a 95kV BIL impulse withstand rating, 34kV AC one-minute withstand, and 53kV DC 15-minute withstand. The connector supports continuous and loadbreak operations up to 200A with a 10kA symmetrical momentary and fault close rating for 10 cycles. Designed for compatibility with cable insulation diameters ranging from 0.640 inches to 0.820 inches, the 167LRT-F5210 accommodates compressed stranded conductor sizes from AWG #3 up to AWG #2 solid, with a cross-sectional area of 26.67 mm². The integrated bi-metal compression lug (02800X) ensures secure, durable connections, while the included 02800X bi-metal contact enhances electrical performance and longevity. The loadbreak-rated tap point must be covered with an insulated cap when not in use to maintain full shielding and submersibility. The 167LRT-F5210 is installed using the supplied installation tool (200-15) and includes a wrench (271-94), lubricant (82-08), and installation instructions (IS-0354-167LRT). The connector mates with ANSI Std. 386, Fig. 5 bushing wells and conforms to Fig. 3 well dimensions. With a fully molded rubber housing, this elbow connector provides corrosion resistance and environmental protection in harsh operating conditions. Ideal for phasing, grounding, testing, or arrester protection in 15kV-class distribution apparatus, the 167LRT-F5210 is a critical component for medium voltage power distribution networks.
  • 200 Amp, 15kV deadbreak connector rated per ANSI/IEEE Standard 386
  • Fully-shielded, fully submersible molded rubber housing for environmental protection
  • Loadbreak-rated tap point for safe switching, grounding, testing, or arrester protection
  • Supports cable insulation diameters from 0.640" to 0.820" and conductor sizes AWG #3 to #2 solid
  • Includes bi-metal compression lug (02800X) and installation tool for reliable connections

Specifications

Amperage Rating
200 A
Application
15kV, 200 Amps
Color
Black
Conductor Range
#3 STR/COMPR AWG , #2 SOL/COMPT AWG
Connection Type
Bolted Elbow with Tap
Current Rating
200 A
Environmental Conditions
Fully Submersible
Insulation
True
Material
Bi-Metal
Material
Housing - EPDM-Rubber
Series
167LRT
Size
Cable Insulation Diameter 0.640 inch to 0.820 inch
Special Features
Includes 02800X Bi-Metal Contact
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Bolted Elbow with Tap
Voltage Rating
15 kV
Voltage Rating
15kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV 200 Amp, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.665 inch to 0.895 inch. Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67.

168ELR-6689-5210

15kV 200 Amp, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.665 inch to 0.895 inch. Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67.
POWER TERMINALS TYPE 3 RENTAL

45030034

POWER TERMINALS TYPE 3 RENTAL
15kV 200 Amp, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

167LRT-G5240

15kV 200 Amp, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
200 Amp, 25kV, Loadbreak Replacement Elbow Connector without Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

273RLR-J-5240

200 Amp, 25kV, Loadbreak Replacement Elbow Connector without Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.640 inch to 0.820 inch. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

167RLR-F-5220

15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.640 inch to 0.820 inch. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

167RLR-H-5270

15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
15/25kV 200 Amp, Deadbreak Straight Receptacle (All Copper Lug), Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

K151SR-B2230

15/25kV 200 Amp, Deadbreak Straight Receptacle (All Copper Lug), Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

376LR-K-5270

35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

Frequently Asked Questions

What is the 167LRT's voltage and current rating?

The 167LRT is rated as a 15kV voltage class, 200 Amp continuous and loadbreak deadbreak connector.

What are the primary applications for the 167LRT?

It is designed for connecting to and operating 15kV-class, 95BIL distribution apparatus, providing a loadbreak operating interface.

What is the DC 15-minute withstand rating?

The DC 15-minute withstand rating is 53kV DC.

What is the AC one-minute withstand rating?

The AC one-minute withstand rating is 34kV AC.

What is the impulse withstand rating of the 167LRT?

The 167LRT has a 95kV BIL Impulse Withstand rating (1.2 x 50 microsecond wave).

What items are included in the 167LRT Bolted Elbow kit?

The kit includes the elbow connector housing, compression lug, stud extender, lubricant, installation tool, wrench, and installation instructions.

What standards does the 167LRT conform to for mating?

The 167LRT conforms to ANSI Std. 386, Fig. 5 and mates with bushing wells conforming to ANSI Std. 386, Fig. 3.

What should be done with the loadbreak tap point when not in use?

The loadbreak-rated tap point must be covered with an insulated cap when not in use.

What tool is needed to install the 167LRT?

The 167LRT is installed using the installation tool (200-15) supplied with the product kit.

Is the 167LRT connector submersible?

Yes, it features a fully-shielded, fully submersible molded rubber housing when mated with the appropriate connector or insulated cap.

How to Install the 167LRT Loadbreak Bushing Tap

This guide provides step-by-step instructions for the safe installation and initial setup of the Elastimold 167LRT Loadbreak Bushing Tap. This device is designed to terminate UD cable and interface with 15kV class loadbreak elbows or accessories. All apparatus must be de-energized during installation.

Estimated time: 2h

Tools needed:

Wrenches, Installation Tool, Wire brush, Crimp tool, Hotstick

Supplies needed:

Lubricant (Do Not Substitute), Compression Lug, Socket Contact, Well Contact, No. 14 AWG (2.5mm) copper wire, Grounding connector, Insulated Cap or Elbow (mating product)

  1. Train the Cable

    Train the UD cable as shown in the diagram to ease future operation. Cut the excess cable squarely at the center line of the bushing, ensuring a minimum of 20 inches beyond the end of the cable.

  2. Prepare Cable End for Termination

    Unwrap and bind the concentric neutral wires 8-1/2 inches back from the end of the cable. Remove the shield and insulation from the cable end, cutting squarely and taking care not to nick the conductor. Wire brush bare aluminum conductors and immediately install the compression lug, rotating it to spread inhibitor. Position the compression lug so its contact threaded hole aligns with the bushing bore. Refer to the crimp chart for tool information, starting crimp at the mark and rotating 180 degrees for successive crimps. Carefully wipe excessive inhibitor from the lug and cable. Remove the semi-con shield as shown, and bevel the insulation end 1/8 inch maximum. Thoroughly clean the insulation to remove all traces of conductive residue.

  3. Assemble Bushing Well Contact

    Thread the well contact onto the bushing well stud by hand, taking care not to cross-thread. Tighten with the supplied wrench until the wrench bends, signifying proper torque.

  4. Install Bushing Tap Housing

    Remove the protective cap from the bushing tap and retrieve the socket contact stored inside. Lubricate the cable insulation and the inside of the bushing housing with the supplied lubricant; do not substitute. Keep insulation clean and avoid introducing grease into the gap between the lug and insulation. Slide the bushing tap onto the cable using a back-and-forth twisting motion, then wipe off all excess grease. Align the bushing with the compression lug hole and assemble the socket contact into the bushing tap, ensuring the socket contact stud passes through the lug hole.

  5. Mount and Torque Bushing Tap

    Inspect the apparatus bushing well to ensure it is dry and free from contaminants. Lubricate the bushing well interface area of the bushing tap with the supplied lubricant. Place the lubricated bushing tap into the apparatus bushing well. Insert the installation tool into the bore of the bushing tap until fully seated. Insert the wrench through the wrench hole of the tool and turn clockwise until the wrench bends, indicating proper assembly torque. Remove the wrench and installation tool.

  6. Connect Concentric Neutral to Ground

    Insert one end of a No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the bushing tap, twisting it tight without damaging the eye. Twist the neutral wires and connect them to ground using an appropriate connector.

  7. Prepare Bushing Tap for Mating Product

    Thoroughly wipe the bushing tap interface clean of any contaminants. Apply a light, uniform coat of supplied lubricant, working it thoroughly into the surface. CAUTION: Excess lubricant may prevent a loadbreak elbow from being fully seated in the 'locked on' position. Install the mating products (e.g., loadbreak elbow, insulated cap, or grounding elbow) following their specific instructions. If not immediately mating, replace the shipping cap, but do not energize or submerge the apparatus with only the shipping cap, as it is not insulated or watertight.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.