ABB - Installation Products 375LR-K-5250-S - 200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1090 inch to 1.310 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS Jacket Seal Included.

ABB Installation Products 375LR-K-5250-S 200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter…

UPC: 783786500048


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 375LR-K-5250-S is a 200 Amp, 35kV loadbreak elbow connector designed for underground residential distribution (URD) and pad-mounted switchgear applications. This connector accommodates cable insulation diameters from 1.090 inch to 1.310 inch and supports compressed stranded conductors sized 2/0 AWG, solid 3/0 AWG, or 67.43 mm². The bi-metal compression lug ensures reliable conductivity between aluminum conductors and copper terminations, reducing corrosion risk in wet or corrosive environments. The unit includes a 200ECS jacket seal for environmental protection against moisture, dust, and contaminants, maintaining dielectric integrity under loadbreak conditions. The loadbreak feature allows safe connection and disconnection under load without interrupting service, critical for maintenance and fault isolation in medium-voltage systems. The connector is rated for 35kV phase-to-phase and meets industry standards for dielectric strength and mechanical durability.
  • 200 Amp continuous current rating, 35kV phase-to-phase
  • Accommodates cable insulation diameters from 1.090" to 1.310"
  • Bi-metal compression lug for aluminum-to-copper transitions
  • Supports compressed stranded 2/0 AWG, solid 3/0 AWG, or 67.43 mm² conductors
  • Includes 200ECS jacket seal for environmental protection

Specifications

Amperage Rating
200 A
Application
35 kv, 200 Amp
Color
Black
Conductor Range
2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG
Connection
Push-In
Connection Type
LoadBreak Elbow Connector
Current Rating
200 A
Environmental Conditions
Fully Submersible
Insulation
True
Material
Bi-Metal Compression Lug
Material
Housing - EPDM-Rubber
Series
375LR-K
Size
Cable Insulation Diameter 1.090 inch to 1.310 inch
Special Features
35kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
3.4900 L
Package Weight (Metric)
1.5830 kg
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

375LR-J-5250

200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

375LR-J-5220

200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

375LR-L-5270

200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

375LR-J-5240

35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

375LR-H-5250

200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

274RLR-K-5270

25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

375LR-J-5230

35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1090 inch to 1.310 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

375LR-K-5250

200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1090 inch to 1.310 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

Frequently Asked Questions

How is the voltage class visually indicated?

The color-coded PBT interface shield indicates voltage class: red for 15 kV, blue for 25 kV, and black for 35 kV.

Are these products compatible with existing systems?

Yes, they can be universally applied to all IEEE 386 compliant interfaces without costly cable rework or installing additional elbows in existing systems.

What are the benefits of the PBT interface shield?

It provides an excellent dielectric mating surface, visual voltage class indication, confirms full insertion, and prevents rubber-to-rubber sticking.

What is the current rating of these products?

Both the Elastimold loadbreak elbows and bushing inserts are rated for 200 amps.

What voltage classes are available for bushing inserts?

Elastimold 200 amp bushing inserts are available for 15 kV, 25 kV, and 35 kV system voltages.

What voltage classes do the loadbreak elbows support?

The Elastimold 200 amp loadbreak elbows are designed for 15 kV and 25 kV series systems.

What is the current rating of these products?

Both the Elastimold loadbreak elbows and bushing inserts are rated for 200 amps.

What voltage classes do the loadbreak elbows support?

The Elastimold 200 amp loadbreak elbows are designed for 15 kV and 25 kV series systems.

What voltage classes are available for bushing inserts?

Elastimold 200 amp bushing inserts are available for 15 kV, 25 kV, and 35 kV system voltages.

What are the benefits of the PBT interface shield?

It provides an excellent dielectric mating surface, visual voltage class indication, confirms full insertion, and prevents rubber-to-rubber sticking.

How to Install Elastimold 375LR/376LR Loadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation, cable preparation, and connection of Elastimold 375LR and 376LR Loadbreak Elbow Connectors to UD cable and 35kV class bushings.

Estimated time: 1h 30m

Tools needed:

Probe wrench, Wire brush, Crimp tool, Hotstick (insulated live-line tool), Wire strippers, Suitable sensing device (for 376LR voltage test)

Supplies needed:

Elbow connector housing, Compression lug, Probe, Lubricant (supplied, do not substitute), Copper wire (No. 14 AWG / 2.5mm), Appropriate connector (for grounding), HV insulated cap(s) or connector(s), Silicone grease

  1. Perform Pre-Installation Checks and Safety Precautions

    Ensure all apparatus is de-energized before beginning installation or removal of parts, except for test point caps and indicators. Inspect all components (Elbow Connector Housing, Compression Lug, Probe) for damage, proper rating, and compatibility with the cable and mating products. Verify the probe threads freely into the compression lug for at least four turns. Read all instructions thoroughly and have all required tools and supplies ready. Remove any protective shipping covers and replace with appropriate HV insulated caps or connectors if submerging or energizing the circuit.

  2. Prepare the Cable

    Train the cable to ease operation, ensuring at least 20 inches of excess cable beyond the end of the bushing pad. Cut the excess cable squarely at the bushing's center line. Unwrap and bind the concentric neutral wires 8-1/2 inches back from the cable end. Carefully remove the insulation shield and insulation from the cable end, ensuring not to nick the conductor. Wire brush the bare aluminum conductors and immediately install the compression lug, rotating it to spread the inhibitor. Align the lug's threaded hole with the bushing bore and crimp according to the supplied chart. Remove the insulation shield as shown in the template, beveling the insulation end a maximum of 1/8 inch. Thoroughly clean the insulation to remove all conductive residue.

  3. Assemble the Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off any excess grease. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the probe wrench until the wrench bends.

  4. Connect the Concentric Neutral

    Insert one end of a No. 14 AWG (2.5mm) copper wire through the grounding eye on the elbow and twist it tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Ensure adequate slack in the wires to allow for elbow operation.

  5. Connect the Elbow to the Bushing

    DANGER: Ensure the transformer and elbow are known to be de-energized before lubricating. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a hotstick to the loadbreak connector pulling eye. Remove any insulated cap from the bushing using the hotstick. With firm footing and positive control, withdraw the elbow from the apparatus parking stand. Insert the probe tip approximately 2 inches into the bushing, then immediately push the elbow home with a fast, firm, straight motion, applying sufficient force to engage the internal lock.

  6. Perform Voltage Test (376LR Only)

    If using a 376LR model, remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device and not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points to determine if the cable is energized. Treat the elbow as energized until a 'no voltage' indication is confirmed by other means, as contamination or incorrect equipment can provide false readings. After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.