ABB - Installation Products 375LR-J-5220 - 200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

ABB Installation Products 375LR-J-5220 200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter…

UPC: 783786507863


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 375LR-J-5220 is a 200 Amp, 35kV loadbreak elbow connector designed for underground residential distribution (URD) systems. This connector accommodates cable insulation diameters between 0.980 inch and 1.180 inch, making it suitable for #2 AWG compressed stranded or #1 AWG solid conductors (33.62 mm² cross-section). The bi-metal compression lug ensures reliable electrical contact and mechanical strength in medium-voltage applications. This loadbreak elbow connector is rated for 35kV systems and provides a deadfront interface for safe operation in pad-mounted transformers, switchgear, and junction enclosures. The absence of a test point simplifies installation while maintaining compliance with IEEE 386 standards for loadbreak separable connectors. The compression lug design eliminates the need for soldering or crimping, reducing installation time and potential connection errors. Key applications include underground power distribution networks, commercial and industrial facilities, and utility substations where medium-voltage cable terminations are required. The connector’s compact design and compatibility with standard URD cables make it a practical choice for new installations and system upgrades. Always verify cable compatibility and system requirements before installation.
  • 200 Amp, 35kV loadbreak elbow connector for medium-voltage URD systems
  • Accommodates cable insulation diameters from 0.980" to 1.180"
  • Bi-metal compression lug for #2 AWG compressed stranded or #1 AWG solid conductors (33.62 mm²)
  • Deadfront interface compliant with IEEE 386 standards
  • No test point; designed for pad-mounted transformers and switchgear

Specifications

Amperage Rating
200 A
Application
35 kv, 200 Amp
Color
Black
Conductor Range
#2 STR/COMPR AWG , #1 SOL/COMPT AWG
Connection
Push-In
Environmental Conditions
Fully Submersible
Insulation
True
Material
Housing - EPDM-Rubber
Size
Cable Insulation Diameter 0.980 inch to 1.180 inch
Special Features
35kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
3.1000 L
Package Weight (Metric)
1.4060 kg
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #2 Stranded Wire Size, Bi-Metal Compression Lug

162LR-C5220

15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #2 Stranded Wire Size, Bi-Metal Compression Lug
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

375LR-L-5270

200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

375LR-J-5240

35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

375LR-H-5250

200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

274RLR-K-5270

25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

375LR-J-5230

35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1090 inch to 1.310 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

375LR-K-5250

200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1090 inch to 1.310 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. 200ECS Jacket Seal Included.

376LR-J5230-S

35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. 200ECS Jacket Seal Included.

Frequently Asked Questions

Do the elbows offer options for test points?

Yes, the loadbreak elbows are available with or without a capacitive test point.

What is the current rating of these products?

The products are 200 amp loadbreak elbows and bushing inserts.

Are Elastimold elbows compatible with existing systems?

Yes, they can be universally applied to all IEEE 386 compliant interfaces without costly cable rework on existing systems.

How can I identify the voltage class of a bushing insert?

The color-coded PBT interface shield indicates the voltage class: red for 15 kV, blue for 25 kV, and black for 35 kV.

What is the purpose of the PBT interface shield?

The PBT interface shield provides an excellent dielectric mating surface, prevents rubber-to-rubber sticking, and offers visual voltage class indication.

What material is used for the elbow housing?

The elbow housing is made from 100% peroxide-cured EPDM for lasting durability.

Are Elastimold bushing inserts suitable for submerged conditions?

Yes, Elastimold 200 amp bushing inserts are designed for exceptional performance, even when fully submerged.

What are the voltage ratings for Elastimold loadbreak elbows?

Elastimold 200 amp loadbreak elbows are available for 15 kV and 25 kV series systems.

How do Elastimold products prevent partial vacuum flashover?

The patented vented ring design, for 25 kV and 35 kV classes, prevents partial vacuum flashover during switching operations.

Do the elbows offer options for test points?

Yes, the loadbreak elbows are available with or without a capacitive test point.

How to Install 375LR/376LR Loadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe installation and wiring of 375LR (without test point) and 376LR (with test point) Loadbreak Elbow Connectors on UD cable.

Estimated time: 1h

Tools needed:

Probe Wrench, Hotstick, Wire brush, Crimp tool, Wire strippers

Supplies needed:

Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied, do not substitute), No. 14 AWG / 2.5mm copper wire, Appropriate grounding connector

  1. Perform Initial Safety Checks and Component Inspection

    DANGER: Ensure all apparatus is de-energized before starting. Inspect all parts for damage, proper rating, and compatibility with mating components. Verify package contents are complete and undamaged. Check the fit of all components with the cable and mating products. Thread the probe into the compression lug to check for resistance; replace damaged components if resistance is encountered. Read all instructions thoroughly and maintain cleanliness.

  2. Prepare and Train Cable for Connection

    Train the cable as shown in the diagram to facilitate future operation. Cut excess cable squarely at the center line of the bushing. Unwrap and bind concentric neutral wires 8-1/2 inches back from the cable end. Remove the cable shield and insulation, ensuring not to nick the conductor. Wire brush bare aluminum conductors and immediately install the compression lug, rotating to spread inhibitor. Align the lug's threaded hole with the bushing bore. Crimp the lug per the chart, starting at the crimp line and rotating 180 degrees for successive crimps. Wipe off excess inhibitor. Remove the insulation shield and bevel the insulation end 1/8 inch max. Thoroughly clean the insulation to remove all conductive residue.

  3. Assemble Elbow Housing and Probe

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant ONLY; do not substitute. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off any excess grease. Align the elbow with the compression lug’s threaded hole. Hand-thread the probe into the lug, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the wrench until the wrench bends.

  4. Connect Concentric Neutral Wires

    Insert one end of a separate No. 14 AWG / 2.5mm copper wire (or equivalent) through the grounding eye on the elbow and twist it tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Ensure adequate slack is provided in the wires to allow for future elbow operation.

  5. Connect Elbow to Mating Bushing Plug

    DANGER: Lubricate the receptacle portion of the elbow connector and the mating bushing ONLY if both the transformer and elbow are confirmed to be DE-ENERGIZED. Operate the connection using a full insulated 'hotstick' type live-line tool; DO NOT OPERATE BY HAND. Consult company safe work practices for required hotstick length.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.