ABB - Installation Products 375LR-K-5250 - 200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1090 inch to 1.310 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

ABB Installation Products 375LR-K-5250 200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter…

UPC: 783786654888


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 375LR-K-5250 is a 200 ampere, 35kV loadbreak elbow connector designed for reliable, high-voltage cable terminations in medium-voltage distribution systems. This connector features a bi-metal compression lug that ensures compatibility with both aluminum and copper conductors, supporting sizes from 2/0 to 3/0 AWG (compressed stranded) or 67.43 mm² (solid). The unit accommodates cable insulation diameters between 1.090 and 1.310 inches, making it suitable for a range of medium-voltage cable types used in utility, industrial, and commercial applications. Engineered for loadbreak operations, this elbow connector allows for safe and efficient connection and disconnection under load, reducing downtime during maintenance or reconfiguration. The absence of a test point simplifies installation while maintaining compliance with industry standards for medium-voltage systems. The bi-metal construction ensures long-term electrical integrity and corrosion resistance, critical for outdoor and underground installations where environmental exposure is a concern. Common applications include pad-mounted transformers, switchgear, and underground residential or commercial distribution networks. The 375LR series is a proven solution in ABB’s lineup, trusted for its durability and consistent performance in harsh operating conditions. For specifiers and contractors, this connector provides a cost-effective, field-proven option for medium-voltage cable terminations where reliability and ease of use are paramount.
  • 200A current rating for medium-voltage applications
  • 35kV voltage rating for reliable high-voltage performance
  • Bi-metal compression lug for aluminum and copper conductors (2/0-3/0 AWG, 67.43 mm² solid)
  • Loadbreak design enables safe connection/disconnection under load
  • Accommodates cable insulation diameters from 1.090" to 1.310"

Specifications

Amperage Rating
200 A
Application
35 kv, 200 Amp
Color
Black
Conductor Range
2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG
Connection
Push-In
Environmental Conditions
Fully Submersible
Insulation
True
Material
Housing - EPDM-Rubber
Size
Cable Insulation Diameter 1.090 inch to 1.310 inch
Special Features
35kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
3.1000 L
Package Weight (Metric)
1.4060 kg
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

375LR-J-5250

200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. 200ECS Jacket Seal Included.

376LR-J5230-S

35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. 200ECS Jacket Seal Included.
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

375LR-L-5240

200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

376LR-J5270

35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

375LR-H5240

200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. .760 inch - .950 Inch Cable Insulation Diameter, 1/0 Stranded or 2/0 kcmil Solid Wire Size, Bi-Metal Compression Lug.

274RLR-G5240

25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. .760 inch - .950 Inch Cable Insulation Diameter, 1/0 Stranded or 2/0 kcmil Solid Wire Size, Bi-Metal Compression Lug.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded #1 or Compacted Solid 1/0 or mmSquared Compact 50.

756LR-K0230

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded #1 or Compacted Solid 1/0 or mmSquared Compact 50.
600 Amp, 35KV, Stick Op Connector Kit with Test Point, Insulated Cap and Reducing Tap Plug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

755LRTP-P0380-DRG

600 Amp, 35KV, Stick Op Connector Kit with Test Point, Insulated Cap and Reducing Tap Plug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

Frequently Asked Questions

Are Elastimold products compatible with existing systems?

Yes, the vented ring design can be universally applied to all IEEE 386 compliant interfaces without costly cable rework or installing additional elbows in existing systems.

How does the PBT interface shield indicate voltage class?

The color-coded PBT interface shield visually indicates the voltage class: red for 15 kV, blue for 25 kV, and black for 35 kV.

How do Elastimold products prevent partial vacuum flashover?

The Elastimold patented vented ring bushing insert design for 25 kV and 35 kV system voltages provides superior protection against partial vacuum flashover.

What are the voltage ratings for Elastimold bushing inserts?

Elastimold 200 amp bushing inserts are available for 15 kV, 25 kV, and 35 kV system voltages.

What are the voltage ratings for Elastimold elbows?

Elastimold 200 amp loadbreak elbows are available for 15 kV and 25 kV system voltages.

How do Elastimold products prevent partial vacuum flashover?

The Elastimold patented vented ring bushing insert design for 25 kV and 35 kV system voltages provides superior protection against partial vacuum flashover.

What are the voltage ratings for Elastimold elbows?

Elastimold 200 amp loadbreak elbows are available for 15 kV and 25 kV system voltages.

What are the voltage ratings for Elastimold bushing inserts?

Elastimold 200 amp bushing inserts are available for 15 kV, 25 kV, and 35 kV system voltages.

How does the PBT interface shield indicate voltage class?

The color-coded PBT interface shield visually indicates the voltage class: red for 15 kV, blue for 25 kV, and black for 35 kV.

Are Elastimold products compatible with existing systems?

Yes, the vented ring design can be universally applied to all IEEE 386 compliant interfaces without costly cable rework or installing additional elbows in existing systems.

How to Install the 375LR/376LR Loadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of 375LR (without test point) and 376LR (with test point) loadbreak elbow connectors on UD cable with concentric neutral and extruded insulation shielding.

Estimated time: 1h 30m

Tools needed:

Probe wrench, Crimp tool (specific to compression lug), Wire brush, Wire strippers, Hotstick (for operation and cap removal), Suitable sensing device (for 376LR voltage test point)

Supplies needed:

375LR or 376LR Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied, do not substitute), UD cable, No. 14 AWG (2.5mm) copper wire (or equivalent for grounding), Appropriate ground connector, HV insulated cap(s) or connector(s) (if replacing shipping covers), Silicone grease (for 376LR test point cap)

  1. Perform Pre-Installation Checks and Cable Training

    DANGER: All apparatus must be de-energized during installation or removal of parts, except for test point caps and indicators. Inspect all parts for damage, proper rating, and compatibility with mating components. Check the package contents for completeness. Thread the probe into the compression lug to ensure free movement for approximately four turns before becoming snug; replace damaged components if resistance is encountered. Train the UD cable as shown in the documentation, ensuring a minimum of 20 inches beyond the end of the cable pad mount transformer to ease future operation. Cut excess cable squarely at the center line of the bushing.

  2. Prepare the Cable

    Unwrap and bind the concentric neutral wires 8-1/2 inches back from the end of the cable. Remove the shield and insulation from the cable end, cutting squarely and taking extreme care not to nick the conductor. Wire brush the bare aluminum conductors thoroughly and immediately install the compression lug. Rotate the lug to spread the inhibitor. Position the compression lug so that its contact threaded hole aligns with the bushing bore. Refer to the crimp chart for recommended crimp tool information, starting the crimp at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excessive inhibitor from the outside of the lug and cable. Remove the insulation shield as shown, then bevel the insulation end to a maximum of 1/8 inch. Thoroughly clean the insulation to remove all traces of conductive residue, ensuring a straight, smooth, and squared finish without cuts or nicks.

  3. Assemble the Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant. DO NOT SUBSTITUTE other lubricants, as they may be harmful. Keep the insulation clean of dirt and grime. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess grease. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, being careful not to cross-thread. The probe must turn freely for approximately four turns before becoming snug. Tighten the probe with the probe wrench until the wrench bends, indicating proper torque.

  4. Connect Concentric Neutral Wires

    Using a separate No. 14 AWG (2.5mm) copper wire or equivalent, insert one end through the grounding eye on the elbow. Twist it tight, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Ensure adequate slack in the wires to allow for future elbow operation.

  5. Connect Elbow to Bushing Plug

    DANGER: Lubricate the receptacle portion of the elbow connector and the mating bushing ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED. DO NOT OPERATE BY HAND. Securely fasten a hotstick to the loadbreak connector pulling eye. After establishing firm footing and positive control, insert the probe tip approximately 2 inches into the bushing. Immediately push the elbow home with a fast, firm, straight motion, applying sufficient force to engage the internal lock on the elbow connector and bushing interface. Do not hold the elbow in the partially inserted position.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.