ABB Installation Products 375LR-J-5240 35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter…
UPC: 783786662371
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 35kV Voltage Class
- 200 Amp Continuous Current Rating
- Accommodates 0.980" to 1.180" Cable Insulation Diameter
- Bi-Metal Compression Lug
- Suitable for 1/0 AWG Stranded / 2/0 AWG Compressed / 53.49 mm² Conductors
- No Test Point Included
- Manufacturer: ABB - Installation Products
- SKU: 375LR-J-5240
Specifications
Amperage Rating | 200 A |
Application | 35 kv, 200 Amp |
Color | Black |
Conductor Range | 1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG |
Connection | Push-In |
Environmental Conditions | Fully Submersible |
Insulation | True |
Material | Housing - EPDM-Rubber |
Size | Cable Insulation Diameter 0.980 inch to 1.180 inch |
Special Features | 35kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector |
Voltage Rating | 35 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 3.1000 L |
Package Weight (Metric) | 1.4060 kg |

376LR-K5240-S
35kV, 200 Amp, LoadBreak, Elbow Connector with Test Point, Cable Insulation 1.090-1.310 inches, Bi-Metal Compression Lug, Conductor Size 1/0 Stranded/Compressed or 2/0 Compact/Solid. With Jacket Seal
375LR-H-5250
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
274RLR-K-5270
25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
375LR-J-5230
35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
375LR-K-5250
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1090 inch to 1.310 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
376LR-J5230-S
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. 200ECS Jacket Seal Included.
375LR-L-5240
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
376LR-J5270
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.Frequently Asked Questions
What voltage classes do Elastimold loadbreak elbows support?
Elastimold 200 amp loadbreak elbows are available for 15 kV and 25 kV systems.
Are these products compatible with existing systems?
Yes, they can be universally applied to all IEEE 386 compliant interfaces without costly cable rework or installing additional elbows in existing systems.
Are the products designed for repeated switching?
Yes, they are optimized for reliability and maximum reliability during repeated switching operations.
Do these products require much maintenance?
They feature an improved seal system designed for maintenance-free operation.
What material is used for the housing?
The housing is made from 100% peroxide-cured EPDM for lasting durability.
Can the elbows be ordered with a test point?
Yes, the loadbreak elbows are available with or without a capacitive test point.
Do the elbows offer different cable range options?
Yes, they offer an improved number of cable ranges for larger conductors, providing increased flexibility.
How does the vented ring design improve safety?
The patented vented ring design, for 25 kV and 35 kV classes, prevents partial vacuum flashover during switching operations.
How does the PBT interface shield enhance safety?
It provides an excellent dielectric mating surface, visual voltage class indication, and confirms full insertion. It also prevents rubber-to-rubber sticking.
What safety features do Elastimold elbows offer?
They are fully shielded with improved insulation, have rigid probe support, a sealed pulling eye, and dual grounding eye positions.
How to Install Elastimold 375LR/376LR Loadbreak Elbow Connectors
This guide provides step-by-step instructions for preparing the cable, assembling the elbow connector, and making the final connection to a 35kV class loadbreak bushing.
Estimated time: 45m
Tools needed:
Wire brush, Crimp tool (refer to lug's crimp chart), Probe wrench, Wire strippers or knife, Hotstick (minimum 8 ft insulated live-line tool)
Supplies needed:
Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied, Do Not Substitute), UD cable, No. 14 AWG (2.5mm) copper wire, Appropriate connector (for grounding neutral wires), Insulated cap (for bushing, if not already present)
- De-energize and Prepare Cable
Safety Warning: Ensure all apparatus is de-energized before beginning installation. Train the UD cable to ease future operation, ensuring at least 20 inches beyond the end of the cable. Cut excess cable squarely at the center line of the bushing. Unwrap and bind concentric neutral wires 8-1/2 inches back from the cable end. Remove the insulation shield and insulation from the cable end, cutting squarely without nicking the conductor.
- Install Compression Lug
Wire brush the bare aluminum conductors immediately. Install the supplied compression lug onto the conductor, rotating it to spread the inhibitor. Position the lug so its contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excessive inhibitor from the outside of the lug and cable.
- Final Cable Insulation Preparation
Remove the remaining insulation shield as shown in the diagram (6-7/8" from cable end). Bevel the insulation end a maximum of 1/8 inch. Thoroughly clean the insulation to remove all traces of conductive residue.
- Assemble Elbow Connector
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off any excess grease. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied probe wrench until the wrench bends.
- Connect Concentric Neutral
Insert one end of a separate No. 14 AWG (2.5mm) copper wire through the grounding eye on the elbow and twist it tight, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Ensure adequate slack in the wires for elbow operation.
- Connect Elbow to De-energized Bushing
Safety Warning: Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant ONLY if the transformer and elbow are known to be de-energized. Do not operate by hand.
- Perform Energized Loadmake Operation (Final Connection)
Safety Warning: This operation requires a full insulated "hotstick" and competent personnel. Ensure the area is clear. Remove the bushing's insulated cap using a hotstick. Securely fasten a hotstick to the elbow's pulling eye. With firm footing and positive control, withdraw the elbow from its parking stand with a fast, straight, firm motion. Insert the probe tip approximately 2 inches into the bushing, then immediately push the elbow home with a fast, firm, straight motion, applying sufficient force to engage the internal lock.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.