Contact for Pricing
Overview
- 15kV operating voltage rating
- 200 Amp continuous current rating
- Integrated test point for safe voltage verification
- Accommodates cable insulation diameters from .805" to 1.060"
- Bi-metal compression lug for #2 stranded wire
Specifications
Amperage Rating | 200 A |
Application | 15kV, 200 Amp |
Color | Black |
Conductor Range | #2 STR/COMPR AWG , #1 SOL/COMPT AWG |
Connection | Push-In |
Connection Type | Loadbreak Elbow Connector with Test Point |
Current Rating | 200 A |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Material | Bi-Metal Compression Lug |
Material | Housing - EPDM-Rubber |
Series | 162LR-C5220 |
Size | 0.805 inch - 1.060 inch Cable Insulation Diameter, #2 Stranded Wire Size |
Size | 7.76 inch (197.1 mm) X 9.03 inch (229.4 mm), 2.92 inch (74.2 mm) Diameter |
Special Features | 15kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard. Non-corrosive capacitive test point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector with Test Point |
Voltage Rating | 15 kV |
Voltage Rating | 15kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 2.1200 L |
Package Weight (Metric) | 0.9620 kg |

375LR-J-5220
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
261LR-C5230
25/28kV, 200 Amp, Loadbreak Elbow Connector, .805 inch - 1.060 Inch Cable Insulation Diameter, #1 Stranded Wire Size, Bi-Metal Compression Lug.
162LR-B5270
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, 4/0 Stranded Wire Size, Bi-Metal Compression Lug
162LR-C5210
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #3 Stranded Wire Size, Bi-Metal Compression Lug
162LR-C-5220-S
15kV, 200 Amp, Loadbreak Elbow with Sealing Kit with Test Point. Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1. 200ECS Jacket Seal Included.
162LR-C2270
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
162LR-B5250
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, 2/0 Stranded Wire Size, Bi-Metal Compression LugFrequently Asked Questions
What is the maximum voltage rating for this elbow connector?
The ABB 162LR-C5220 loadbreak elbow connector has a maximum voltage rating of 15kV.
What is the continuous current capacity of this connector?
This connector is rated for a continuous current of 200 Amps.
What cable insulation diameter range does this connector support?
The connector is designed to fit cable insulation diameters between .805 inches and 1.060 inches.
What type of wire size is compatible with the lug?
The bi-metal compression lug is suitable for #2 stranded wire.
Does this connector have a feature for testing?
Yes, the ABB 162LR-C5220 includes a test point for voltage verification.
What material is the compression lug made of?
The connector features a bi-metal compression lug.
How to Install 161LR/162LR Loadbreak Elbow Connectors
A comprehensive guide for preparing cables, assembling, and connecting 161LR and 162LR Loadbreak Elbow Connectors to a 15kV class bushing or accessory device.
Estimated time: 1h 30m
Tools needed:
Probe wrench, Wire strippers, Wire brush, Crimp tool, Hotstick, Cable cutters or knife
Supplies needed:
161LR or 162LR Loadbreak Elbow Connector Kit (includes elbow housing, compression lug, probe, lubricant), UD Cable (appropriate for the connector), Copper wire (No. 14 AWG / 2.5mm), Appropriate connector for neutral wires, Cold shrink sealing kit (if applicable for cable type), Conductive copper tape (if applicable for cable type), Vinyl tape (if applicable for cable type), Cleaning agent
- Ensure Safety and Inspect Components
Before beginning installation, ensure all apparatus is de-energized to prevent serious or fatal injury. Inspect all components of the 161LR/162LR kit for damage, proper rating, and compatibility with the cable and mating bushing. Check the compression lug and probe threads for smooth engagement.
- Prepare the Cable
Train the cable to ensure adequate slack for future operation. Based on your cable type (non-jacketed, jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield), follow the specific instructions to manage neutral or drain wires, cut the cable squarely at the bushing centerline, and remove the outer jacket and/or copper tape shield to the specified lengths. If using a cold shrink sealing kit, slide the cold shrink tube onto the cable at this stage.
- Prepare Conductor and Insulation
Remove 2-1/8 inches (55mm) of the insulation shield and insulation from the cable end, ensuring a square cut without nicking the conductor. Wire brush the bare aluminum conductors thoroughly and immediately install the compression lug, rotating it to spread any inhibitor. Position the lug so its threaded hole aligns with the bushing bore, then crimp it according to the manufacturer's chart. Carefully wipe off any excess inhibitor. Remove 6-7/8 inches (175mm) of the insulation shield and bevel the insulation end by a maximum of 1/8 inch (5mm). Thoroughly clean the insulation to remove all dirt and inhibitor.
- Assemble the Elbow Connector
Apply the supplied lubricant to the cable insulation and the inside of the elbow housing; do not use substitute lubricants. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off any excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the probe wrench until the wrench bends.
- Ground the Elbow
Insert one end of a separate No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the elbow and twist it tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack for elbow operation. If using a cold shrink grounding kit, refer to its specific instructions.
- Connect Elbow to Bushing
Crucially, confirm that both the transformer and the elbow are de-energized before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Using a fully insulated hotstick tool, securely fasten it to the loadbreak connector pulling eye and connect the elbow to the bushing with a fast, firm, straight motion, ensuring the internal lock engages.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.